| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| CEL 041-2020 | English | 1079 |
Add to Cart
|
5 days [Need to translate]
|
Implementation rules for energy efficiency labels of air ducted air-conditioning units
| |
CEL 041-2020
|
Standard similar to CEL 041-2020
Basic data | Standard ID | CEL 041-2020 (CEL041-2020) | | Description (Translated English) | Implementation rules for energy efficiency labels of air ducted air-conditioning units | | Sector / Industry | Chinese Industry Standard | | Word Count Estimation | 27,253 | | Summary | This standard is applicable to air duct air-conditioning (heat pump) units that use motor-driven compressors, indoor units with a static pressure greater than 0Pa (gauge pressure), and new evaporative air handling units. Not applicable to multi-unit air conditioner (heat pump) units. |
CEL041-2020: Implementation rules for energy efficiency labels of air ducted air-conditioning units ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Implementation rules for energy efficiency labels of air ducted air-conditioning units
Implementation rules for energy efficiency labels of air ducted air-conditioning units
1 General
1.1 These rules are formulated in accordance with the "Energy Efficiency Label Management Measures" (hereinafter referred to as "Measures").
1.2 This rule applies to the use of motors to drive compressors, the indoor unit static pressure is greater than 0 Pa (table
Pressure) air duct air-conditioning (heat pump) unit and direct evaporative new air
Management unit (hereinafter referred to as air conditioner) energy efficiency label (hereinafter referred to as logo) use, filing and announcement.
Not applicable to multi-unit air conditioner (heat pump) units.
2 Logo style and specifications
2.1 The logo is a blue and white background color logo with a length of 109 mm and a width of 66 mm.
2.2 The name of the label is. China Energy Efficiency Label (English name is CHINA ENERGY
LABEL), air-cooled single-cooled duct air supply unit includes the following.
(1) The name (or abbreviation) of the producer;
(2) Product specifications and models;
(3) Energy efficiency rating;
(4) Energy efficiency ratio in cooling season [(W · h)/(W · h)];
(5) Cooling capacity (W);
(6) Power consumption during cooling season (kW · h);
(7) The mandatory national standard number for energy efficiency;
(8) Energy efficiency information code;
(9) Energy efficiency "leader" information (only for products included in the national energy efficiency "leader" catalog).
Air-cooled heat pump air duct air supply unit includes the following.
(1) The name (or abbreviation) of the producer;
(2) Product specifications and models;
(3) Energy efficiency rating;
(4) Annual performance coefficient [(W · h)/(W · h)];
(5) Cooling capacity (W);
(6) Heating capacity (W);
(7) Power consumption during cooling season (kW · h);
(8) Power consumption during heating season (kW · h);
(9) The mandatory national standard number of energy efficiency;
(10) Energy efficiency information code;
(11) Energy efficiency "leader" information (only for products included in the national energy efficiency "leader" catalog).
Water-cooled air duct air supply unit includes the following.
(1) The name (or abbreviation) of the producer;
(2) Product specifications and models;
(3) Energy efficiency rating;
(4) Refrigeration integrated partial load performance coefficient (W/W);
(5) Cooling capacity (W);
(6) Refrigeration power consumption (W);
(7) The mandatory national standard number for energy efficiency;
(8) Energy efficiency information code;
(9) Energy efficiency "leader" information (only for products included in the national energy efficiency "leader" catalog).
Direct evaporative new wind air treatment unit includes the following.
(1) The name (or abbreviation) of the producer;
(2) Product specifications and models;
(3) Energy efficiency rating;
(4) Energy efficiency ratio (W/W);
(5) Cooling capacity (W);
(6) Refrigeration power consumption (W);
(7) The mandatory national standard number for energy efficiency;
(8) Energy efficiency information code;
(9) Energy efficiency "leader" information (only for products included in the national energy efficiency "leader" catalog).
2.3 An example of the logo style is shown in Annex 1, which can be downloaded from the "China Energy Efficiency Label Network".
3 Energy efficiency testing
3.1 Energy efficiency ratio in cooling season, annual performance coefficient, comprehensive load partial refrigeration performance coefficient,
Energy efficiency ratio, cooling capacity, cooling power consumption, power consumption during cooling season, heating capacity, heating
Power consumption, power consumption in heating season, energy efficiency ratio in heating season, electric auxiliary heating control function
The testing methods of energy efficiency related parameters of energy and other products should be based on the currently valid version of GB 37479.
3.2 "Test Report of Energy Efficiency of Air Duct Air Supply Units" (hereinafter referred to as the Test Report)
The format can be downloaded from "China Energy Label".
3.3 Producers or importers can use their own testing laboratories, or entrust them to obtain according to law
Qualified third-party inspection and testing institutions to test products, and according to energy efficiency
Rate mandatory national standards to determine product energy efficiency grades.
Producers or importers who use their own testing laboratories to determine energy efficiency grades should ensure that
Prove that its testing laboratory has the ability to perform testing in accordance with mandatory national standards for energy efficiency,
And encourage them to obtain the recognition of national accreditation bodies.
3.4 Those who use their own testing laboratory for testing should provide a laboratory testing capability certificate
Ming materials (including laboratory personnel capabilities, equipment capabilities and testing management specifications) have been
If it is approved by a national accreditation body, it should also provide a copy of the corresponding accreditation certificate; use
A third-party inspection and testing agency shall provide a copy of the qualification certification certificate of the inspection and testing agency.
Authorized institutions should be responsible for the energy efficiency labels and product energy efficiency used by producers and importers.
Check the inspection report.
4 Identification of identification information
4.1 Producer refers to the owner or user of a product brand that is legally responsible for product quality.
4.2 The product specification and model should be consistent with the label on the nameplate.
4.3 Energy efficiency grade, energy efficiency ratio in cooling season, annual performance coefficient, negative in the comprehensive cooling part
Charge performance factor, energy efficiency ratio, cooling capacity, cooling power consumption, power consumption during cooling season,
Heating capacity, heating power consumption, power consumption in heating season, energy efficiency ratio in heating season, electric auxiliary
Related parameters of energy efficiency performance of products such as auxiliary heating control function should be based on the current GB 37479
Confirm the valid version and test report. Energy Efficiency Ratio and Refrigeration Department
Load sharing performance coefficient, energy efficiency ratio in cooling season, and annual performance coefficient should not exceed the corresponding energy
The value range of the effectiveness level.
4.4 The compulsory national standard for energy efficiency refers to the currently valid version of GB 37479.
4.5 The manufacturer or importer directly generates the product energy efficiency information code from the identification information system when filing.
4.6 Products listed in the national energy efficiency "leader" catalog should be marked with energy efficiency "leader" information.
5 Printing, applying and displaying the logo
5.1 Every unit (set) that is shipped or imported should be marked.
5.2 The producer or importer prints its own logo and is responsible for the quality of the print.
5.3 The logo shall be printed on coated paper of 80 grams and above.
5.4 The mark should be applied to the obvious parts of the unit indoor unit, and on the product packaging or
Explain in the instruction manual. If the product is traded through online commodities,
The corresponding logo is displayed in a prominent position on the main page of information display.
5.5 The mark applied to the unit should conform to the provisions of Article 2
Words and colors cannot be changed. The marking specifications can be scaled up on the basis of the provisions of Article 2.1 of this rule.
5.6 The main page of product packaging, instruction manuals, and online trading product information display
The logo used in the publicity can be enlarged or reduced in proportion, and the paper version can be printed in monochrome.
The text in the logo should be legible.
5.7 The products listed in the national energy efficiency "leader" catalogue are shipped out 30 days after the catalogue is published.
Products should use a logo that contains information on the "leader" of energy efficiency.
6 Filing of the logo
6.1 The producer or importer shall file one by one according to the product specifications and models. Different models
However, the refrigeration system is the same, the structure is the same, and the energy efficiency performance indicators of the main products are the same (refrigeration season
Energy-saving efficiency ratio, annual performance coefficient, refrigeration integrated partial load performance coefficient, energy efficiency ratio phase
Same) products can no longer submit test reports when filing.
6.2 Producers and importers should apply to authorized agencies for filing, and at the same time
"Net of Marking" fills in the "Energy Efficiency Marking Record Form for Duct Air Supply Air Conditioning Unit", etc.
Relevant filing materials specified in the "Measures".
The record materials should be true, accurate and complete.
6.3 When the content of the product logo changes, it shall be filed with the authorized institution again.
6.4 For those who do not meet the requirements of Article 6.2 of this rule, the authorized institution shall notify the producer or
The exporter promptly added materials or replaced the used logo.
6.5 Materials in foreign languages shall be accompanied by Chinese translations, and the Chinese text shall prevail.
7 Logo announcement
7.1 The authorized institution shall verify and revoke the
Relevant filing information and timely announcement.
7.2 The authorized institution should establish a product information database
Doors, etc. provide product information query services, verify and announce the verification and supervision and inspection of signs in a timely manner.
7.3 Enterprises, consumers and other relevant parties can make complaints and report violations of labeling in the following ways.
|