US$959.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. CEL 020-2021: (Implementation rules for energy efficiency labeling of power transformers)
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| CEL 020-2021 | English | 959 |
Add to Cart
|
3 days [Need to translate]
|
(Implementation rules for energy efficiency labeling of power transformers)
| |
CEL 020-2021
|
Standard similar to CEL 020-2021
Basic data | Standard ID | CEL 020-2021 (CEL020-2021) | | Description (Translated English) | | | Sector / Industry | Chinese Industry Standard |
CEL020-2021: (Implementation rules for energy efficiency labeling of power transformers)---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Implementation rules for energy efficiency labeling of power transformers)
Implementation rules for energy efficiency labeling of power transformers
- 1 -
1 General
1.1 This rule is based on the "Measures for the Administration of Energy Efficiency Labeling" (hereinafter referred to as the "Measures")
Formulate.
1.2 This rule applies to the rated frequency of 50 Hz, three-phase 10 kV voltage level, no excitation
Voltage regulation, oil-immersed distribution transformer with rated capacity 30 kVA~2 500 kVA and rated capacity
Dry-type distribution transformers with a capacity of 30 kVA~2 500 kVA, rated frequency of 50 Hz,
Three-phase oil with a pressure level of 35 kV~500 kV and a rated capacity of 3 150 kVA and above
Energy efficiency of immersed power transformers, etc. (corresponding to Table 1~Table 28 of GB.20052-2020)
The use, filing and announcement of the rate mark (hereinafter referred to as the mark).
Not suitable for gas-filled transformers and high-impedance transformers.
2 Logo style and specifications
2.1 The logo is a color logo with a blue and white background, with a length of 66 mm and a width of 45 mm.
2.2 The label name is. China Energy Efficiency Label (English name is CHINA ENERGY
LABEL).
The distribution transformer includes the following.
(1) The name of the producer (or abbreviation);
(2) Specifications and models;
(3) Energy efficiency rating;
(4) No-load loss (W);
(5) Load loss (Dyn11/Yzn11/Yyn0) (only applicable to oil transformer) or (B/F/H) (only
- 2 -
Applicable dry change) (W);
(6) Core material (electrical steel strip/amorphous alloy);
(7) The number of the mandatory national energy efficiency standard on which it is based;
(8) Energy efficiency information code;
(9) Information on energy efficiency "leading runners" (only for those listed as national energy efficiency "leading runners"
Catalog products).
Power transformers include the following.
(1) The name of the producer (or abbreviation);
(2) Specifications and models;
(3) Energy efficiency rating;
(4) No-load loss (kW);
(5) Load loss (75°C) (kW);
(6) The number of the mandatory national energy efficiency standard on which it is based;
(7) Energy efficiency information code;
(8) Information on energy efficiency "leading runners" (only for those listed as national energy efficiency "leading runners"
Catalog products).
2.3 See Annex 1 for an example of the label style, which can be found on the "China Energy Efficiency Labeling Network"
3 Energy efficiency testing
3.1 The detection of energy efficiency performance related parameters such as no-load loss and load loss should be based on
-3-
The currently valid version of GB.20052.
3.2 The format of the "Power Transformer Energy Efficiency Test Report" (hereinafter referred to as the test report)
Load.
3.3 Producers or importers can use their own testing laboratories, or entrust them to obtain
Qualified third-party inspection and testing institutions conduct product inspections, and based on energy efficiency
Rate compulsory national standards and determine product energy efficiency ratings.
Producers or importers who use their own testing laboratories to determine energy efficiency levels shall ensure that
Certify that its testing laboratory is capable of testing in accordance with mandatory national standards for energy efficiency
And encourage them to obtain accreditation from national accreditation bodies.
3.4 If you use your own testing laboratory for testing, you should provide a laboratory testing ability certificate
Clear materials (including laboratory personnel capabilities, equipment capabilities and testing management practices), have been
If it has been approved by a national accreditation body, a copy of the corresponding accreditation certificate shall also be provided;
If a third-party inspection and testing agency conducts testing, it shall provide the qualification certification of the inspection and testing agency.
A copy of the certificate.
Authorized agencies should review the energy efficiency labels and product energy efficiency used by producers and importers.
The test report is verified.
4 Determination of identification information
4.1 The producer refers to the owner or user of the product brand who is legally responsible for the quality of the product
By.
-4-
4.2 The specifications and models should be consistent with the markings on the nameplate.
4.3 The energy efficiency performance related parameters such as energy efficiency grade, no-load loss and load loss shall be based on
According to the currently valid version and test report of GB.20052.No-load loss
The power consumption and load loss should not exceed the value range of the corresponding energy efficiency level. Empty of the product under test
The load loss and load loss should meet the marked values on the energy efficiency label.
4.4 The compulsory national standard for energy efficiency refers to the currently valid version of GB.20052
this.
4.5 The label information system directly generates the product energy efficiency letter from the manufacturer or importer when filing
Information code.
4.6 Products listed in the national energy efficiency "leader" catalogue should be marked with energy efficiency "leader"
information.
5 Printing, application and display of logo
5.1 Every power transformer shipped or imported should be marked.
5.2 The manufacturer or importer prints the label on its own and is responsible for the quality of the printing.
5.3 The label should be printed with other durable materials such as 80 grams or more of coated paper or metal.
system.
5.4 The label shall be pasted, hung or fixed on the obvious part of the power transformer, and shall be attached to the product
It is stated on the packaging or in the instruction manual. Products are traded through online commodities,
The corresponding logo should also be displayed in a prominent position on the main page of the product information display.
5.5 The label applied to the power transformer shall comply with the provisions of Article 2 of this rule, as shown in the figure
The pattern, text and color cannot be changed. The marking specifications can be specified in Article 2.1 of this rule
Based on the scaling up.
5.6 In the product packaging, manuals, online trading product information display main page and
The logo used in the advertisement can be enlarged or reduced proportionally, and the paper version can be printed in monochrome.
Brush, the text in the logo should be legible.
5.7 Products listed in the national energy efficiency "leader" catalog will be shipped 30 days after the catalog is released
Of products should use energy efficiency labels that contain information on energy efficiency "leading runners".
6 Mark filing
6.1 The manufacturer or importer shall file for the record one by one according to the product specifications and models. Distribution transformer
Same transformer category, same core material and structure, same coil wire material, same
Outer winding insulation material and insulation system temperature (only applicable to dry-type transformers), electrical
The force transformer is divided into the filing form according to the same voltage level, the same voltage regulation method, the number of windings, etc.
Yuan, the specific filing unit division and sample requirements are shown in Table 1 and Table 2.
For products with the same filing unit, fill out a filing form, and submit the inspection of the specified specifications and models.
Test report, other specification products do not need to submit test report.
Table 1 Division of filing units of distribution transformers and sample requirements
-6-
6.2 Producers and importers should apply to the authorized agency for filing, and at the same time in the "China Energy
Fill in the "Power Transformer Energy Efficiency Label Recording Form" on the "Efficiency Labeling Network" (see attachment
3) Wait for the relevant filing materials required by the Measures.
The filing materials should be true, accurate and complete.
6.3 When the content of the product label changes, it shall be re-filed with the authorized agency.
6.4 For those that do not meet the requirements of Article 6.2 of this rule, the authorized institution shall notify the producer or importer
The exporter promptly supplements materials or replaces the used logo.
6.5 Foreign language materials should be accompanied by a Chinese translation, and the Chinese version shall prevail.
-7-
7 Announcement of logo
7.1 The authorized institution shall revoke the relevant provisions of the producer or importer of the energy-efficiency substandard product.
Case information and timely announcement.
7.2 The authorized institution shall establish a product information database to provide information to producers, consumers and regulators
Departments, etc. provide product information inquiry services, and timely announce the verification and supervision and inspection of the logo
condition.
7.3 Enterprises, consumers and other relevant parties can invest in label violations in the following ways.
To complain or report.
Telephone/fax. (010)58811745/58811714;
Attachment. 1.Examples of energy efficiency labeling styles for power transformers
2.Power transformer energy efficiency test report
3.Power transformer energy efficiency label filing form
|