YY/T 0829-2011 English PDFUS$789.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0829-2011: Characteristics and test methods for imaging system of positron emission and X-ray computed tomography Status: Valid
Basic dataStandard ID: YY/T 0829-2011 (YY/T0829-2011)Description (Translated English): Characteristics and test methods for imaging system of positron emission and X-ray computed tomography Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended) Classification of Chinese Standard: C43 Classification of International Standard: 11.040.50 Word Count Estimation: 34,343 Date of Issue: 2011-12-31 Date of Implementation: 2013-06-01 Quoted Standard: GB/T 17857-1999; GB/T 18988.1-2003; YY 0310-2005 Regulation (derived from): State Food and Drug Administration Notice No. 106 of 2011 Issuing agency(ies): State Food and Drug Administration Summary: This standard specifies the positron emission and X-ray computed tomography system (hereinafter referred to as PET/CT) terminology, definitions, and performance and test methods. This standard applies to PET/CT, does not apply to independent positron emission tomograph (PET) and independent X-ray computed tomography equipment (CT). YY/T 0829-2011: Characteristics and test methods for imaging system of positron emission and X-ray computed tomography---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Characteristics and test methods for imaging system of positron emission and X-ray computed tomography ICS 11.040.50 C43 People's Republic of China pharmaceutical industry standards Positron emission and X-ray computed tomography System performance and test methods Issued on. 2011-12-31 2013-06-01 implementation State Food and Drug Administration issued Table of ContentsIntroduction Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Performance 1 4.1 PET part of the performance and test methods 1 4.1.1 The spatial resolution of 1 4.1.2 recovery factor of 2 4.1.3 tomographic imaging sensitivity 2 4.1.4 count rate characteristic 2 4.1.5 scatter fraction 2 4.1.6 attenuation correction 2 4.2 CT performance and test methods Part 2 4.2.1 image noise 2 4.2.2 CT value uniformity 2 Accuracy 4.2.3 CT value 2 4.2.4 spatial resolution (high contrast resolution) 2 4.2.5 Low contrast resolution 3 4.2.6 artifact 3 4.2.7 slice thickness 3 4.2.8 CT gantry 3 4.2.9 X-ray generator 3 4.2.10 high voltage cable plug and socket 4 4.2.11 indicating instrument 4 4.3 PET/CT and its test method 4 4.3.1 PET/CT image registration accuracy 4 4.3.2 PET/CT patient support 5 4.3.3 PET/CT system is running noise 5 Appendix A (normative appendix) NEMA Standards Publication NU2-2007 "positron emission tomography device performance test" 7 References 29ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This standard was proposed by the State Food and Drug Administration. This standard by the National Standardization Technical Committee appliances medical radiotherapy, nuclear medicine science equipment at the Technical Committee and the radiation dose (SAC/TC10/SC3) centralized. This standard was drafted. Beijing Medical Device Testing, GE Medical Systems Trade Development (Shanghai) Co., Ltd., Philips (China) Investment Co., Ltd., Siemens (China) Co., Ltd. The main drafters of this standard. Coke spring camp, Feng Jian, Gan Ran Ran, Emily, Nie Tao.IntroductionPositron emission and X-ray computed tomography system in positron emission tomography section (hereinafter referred to as PET portion) Reference and test methods for performance standards for GB/T 18988.1-2003, X-ray computed tomography section (hereinafter referred to as CT section) Performance criteria and test methods cited YY 0310-2005. GB/T 18988.1-2003 identical with the IEC 61675-1.1998. Currently, a major manufacturer of radionuclide imaging apparatus Production sites are located in the United States, are NEMA National Electrical Manufacturers Association for its report parameters, data processing software, test phantom Standards as a basis for the design, but also manufacturers use IEC standard. In order to facilitate the government, enterprises and medical institutions understand and use such production Products two series IEC and NEMA standard content, radiotherapy, nuclear medicine science equipment at the Technical Committee and the radiation dose (SAC / TC10/SC3) with the consent and support of NEMA Board's NEMA Standards Publication NU2-2007 "as positron emission tomography Like device performance test "incorporated this standard, the NEMA standard as a normative appendix to this standard. Since the IEC and NEMA standards there are some differences in testing requirements, test methods, the use of motifs, test conditions, test Position, the calculation method is different, so I can not compare with each other between the two standard test items and complete references recommend two standard user The method of any one species should not be used interchangeably. Positron emission and X-ray computed tomography System performance and test methods1 ScopeThis standard specifies the positron emission and X-ray computed tomography system (hereinafter referred to as PET/CT) terms, definitions and sexual Energy and test methods. This standard applies to PET/CT, does not apply to independent positron emission tomography apparatus (PET) and a separate X-ray computed Tomography apparatus (CT).2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 17857-1999 Medical imaging academic language (radiotherapy, nuclear medicine and radiation dosimetry equipment) GB/T 18988.1-2003 Radionuclide imaging device - Characteristics and test - Part 1. Positron emission tomography Equipment YY 0310-2005 X-ray computer tomography equipment general technical conditions3 Terms and DefinitionsGB/T 17857-1999, GB/T 18988.1-2003, YY 0310-2005 as defined in the following terms and definitions apply This document. 3.1 Attenuation correction attenuationcorrection After radiation of medium strength loss correction. Attenuation caused by absorption or scattering. In the body by correcting the actual attenuation required Measuring the linear attenuation coefficient. General use of radioactive sources or X-ray transmission scan to determine the attenuation coefficient. 3.2 Image registration imageregistration The different sets of image data conversion process to the same coordinate system. Different image data set is a different time and (or) different models of the same Obtaining a data set collected objects.4 Performance4.1 PET part of the performance and test methods 4.1 and performance and test methods specified in Appendix A can choose one, the proposed standard users complete reference in either of two methods It one of the cross should not be used. 4.1.1 Spatial resolution Press Test GB/T 18988.1-2003 be specified in 3.1. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0829-2011_English be delivered?Answer: Upon your order, we will start to translate YY/T 0829-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YY/T 0829-2011_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0829-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |