YS/T 558-2009 English PDFUS$319.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 558-2009: Methods for emission spectrum analysis of molybdenum YS/T 558: Historical versions
Basic dataStandard ID: YS/T 558-2009 (YS/T558-2009)Description (Translated English): Methods for emission spectrum analysis of molybdenum Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H14 Classification of International Standard: 77.120 Word Count Estimation: 9,983 Date of Issue: 2009-12-04 Date of Implementation: 2010-06-01 Older Standard (superseded by this standard): YS/T 558-2006 Regulation (derived from): MIIT [2009] No. 66 Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the molybdenum and molybdenum compounds of iron, cobalt, chromium, cadmium, manganese, magnesium, calcium, titanium, copper, silicon, tin, nickel, aluminum, antimony, lead, bismuth, vanadium content determination. This standard applies to molybdenum and molybdenum compounds of iron, cobalt, chromium, cadmium, manganese, magnesium, calcium, titanium, copper, silicon, tin, nickel, aluminum, antimony, lead, bismuth, vanadium content. Measuring range in Table 1. YS/T 558-2009: Methods for emission spectrum analysis of molybdenum---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Methods for emission spectrum analysis of molybdenum ICS 77.120 H14 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 558-2006 Molybdenum Emission Detector Posted 2009-12-04 2010-06-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released ForewordInstead of the standard YS/T 558-2006 "Emission Detector molybdenum" (formerly GB/T 16599-1996). Compared with this standard YS/T 558-2006, the following main changes. --- The "7.1" in "accurately weighed 0.400g sample" to "5.2" in the "Weigh (0.4 ± 0.001) g sample '; --- The "7.2" in the "sample taken (7.1) and 0.200g buffer (4.19) Research uniform" to "5.3" in the "Take sample (5. 2) and (0.2 ± 0.001) g buffer (3.19) Research uniform "; --- The "7.3" in the "After adjusting each number separately weighed 0.400g and 0.200g standard buffer (4.19) Research uniform" to "5.4" in the "After each take, respectively, said after the calibration standard resolution (0.4 ± 0.001) g and (0.2 ± 0.001) g buffer (3.19) Research uniform"; --- Increasing the foreword, precision and quality assurance and control content, and format of the standard editing. This standard by the National Standardization Technical Committee of non-ferrous metals and centralized. This standard by the Zigong Carbide limited liability company responsible for drafting. This standard by the China Molybdenum Group Co., Jinduicheng Molybdenum Group Co., Ltd. participated in the drafting. The main drafters of this standard. Tan Thai chapter, Wang Pei, Li Wei. This standard certifier. Chen Feng Group, Tangbao Ming, Zhang Cui pigeons, Hou Xinwei, Li Qiao Hong, Wang Feng. This standard replaces the standards previously issued as follows. --- YS/T 558-2006. Molybdenum Emission Detector1 ScopeThis standard specifies the test molybdenum and molybdenum, iron, cobalt, chromium, cadmium, manganese, magnesium, calcium, titanium, copper, silicon, tin, nickel, aluminum, antimony, lead, bismuth, vanadium content of the compound Setting Method. This standard applies to the measurement of molybdenum and molybdenum, iron, cobalt, chromium, cadmium, manganese, magnesium, calcium, titanium, copper, silicon, tin, nickel, aluminum, antimony, lead, bismuth, vanadium content of the compound Set, the range of measurement are shown in Table 1. Table 1% Element measurement range (mass fraction) element measurement range (mass fraction) Iron 0.0003 0.0005 0.012 0.012 silicon Cobalt 0.00025 0.00005 to 0.0024 to 0.012 tin Nickel-chrome 0.0001 0.00015 to 0.012 to 0.008 Cadmium 0.00005 to 0.0040 Al 0.0002 to 0.010 Manganese antimony 0.0001 to 0.0080 0.0002 ~ 0.010 Lead magnesium 0.0002 to 0.010 0.00005 to 0.0024 Calcium bismuth 0.0004 to 0.012 0.00005 to 0.0024 Titanium vanadium 0.0003 0.0003 0.012 to 0.012 Copper 0.00005 to 0.00702 Method summaryThe sample was converted to molybdenum trioxide, the DC arc powder method to ΔP-lg standard curve, quantitative spectral analysis.3 Reagents and materials3.1 trioxide, > 99.995%. 3.2 ferric oxide, pure spectrum. 3.3 silica, pure spectrum. 3.4 aluminum oxide, pure spectrum. 3.5 manganese dioxide, pure spectrum. 3.6 magnesium oxide, pure spectrum. 3.7 nickel oxide, pure spectrum. 3.8 Titanium dioxide, pure spectrum. 3.9 vanadium pentoxide, pure spectrum. 3.10 cobalt oxide, pure spectrum. 3.11 cadmium oxide, pure spectrum. 3.12 lead oxide, pure spectrum. 3.13 bismuth trioxide, pure spectrum. 3.14 tin oxide, pure spectrum. 3.15 antimony trioxide, pure spectrum. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 558-2009_English be delivered?Answer: Upon your order, we will start to translate YS/T 558-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 558-2009_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 558-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YS/T 558-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 558-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |