Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YS/T 556.14-2011 English PDF

US$159.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 556.14-2011: Methods for chemical analysis of antimony concentrates. Part 14: Determination of silver content. Flame atomic absorption spectrometric method
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YS/T 556.14-2011159 Add to Cart 3 days Methods for chemical analysis of antimony concentrates. Part 14: Determination of silver content. Flame atomic absorption spectrometric method Valid

Similar standards

YS/T 575.19   SN/T 3510   GB/T 8152.1   YS/T 556.11   YS/T 556.12   YS/T 556.10   

Basic data

Standard ID: YS/T 556.14-2011 (YS/T556.14-2011)
Description (Translated English): Methods for chemical analysis of antimony concentrates. Part 14: Determination of silver content. Flame atomic absorption spectrometric method
Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard: D42
Classification of International Standard: 73.060
Word Count Estimation: 6,688
Date of Issue: 2011-12-20
Date of Implementation: 2012-07-01
Regulation (derived from): ?MIIT Announcement 2011 No.43
Issuing agency(ies): Ministry of Industry and Information Technology
Summary: This standard specifies the determination of the amount of silver, antimony concentrates. This standard applies to the determination of the amount of silver, antimony concentrates. Measuring range: 10. 00g/t ~ 500. 00g/t.

YS/T 556.14-2011: Methods for chemical analysis of antimony concentrates. Part 14: Determination of silver content. Flame atomic absorption spectrometric method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of antimony concentrates.Part 14. Determination of silver content.Flame atomic absorption spectrometric method ICS 73.060 D42 People's Republic of China Nonferrous Metals Industry Standard Methods for chemical analysis of antimony concentrates Part 14. Determination of silver content Flame Atomic Absorption Spectrometry Part 14. Determinationofsilvercontent- Issued on. 2011-12-20 2012-07-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

This section is in accordance with GB/T 1.1-2009 given rules drafted. YS/T 556 "Methods for chemical analysis of antimony concentrate," a total of 16 parts. --- Part 1. Determination of antimony content cerium sulfate titration; --- Part 2. Determination of arsenic content potassium bromate titration; --- Part 3. Determination of lead content by flame atomic absorption spectrometry; --- Part 4. Wet water storage Gravimetric method; --- Part 5. Determination of zinc content - Flame atomic absorption spectrometry; --- Part 6. Determination of the amount of selenium by hydride generation - atomic fluorescence spectrometry; --- Part 7. Determination of the amount of mercury atomic fluorescence spectrometry; --- Part 8. Determination of sulfur content - Combustion neutralization method; --- Part 9. Determination of the amount of gold fire assay; --- Part 10. Determination of copper content - Flame atomic absorption spectrometry; --- Part 11. Determination of cadmium content by flame atomic absorption spectrometry; --- Part 12. Determination of bismuth content by flame atomic absorption spectrometry; --- Part 13. Determination of nickel content by flame atomic absorption spectrometry; --- Part 14. Determination of the amount of silver by flame atomic absorption spectrometry; --- Part 16. lead, zinc, copper, cadmium, nickel content - Inductively coupled plasma atomic emission spectrometry. This is Part 14. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is responsible for drafting unit. tin mine Twinkling Star Antimony Industry Co., Ltd., Beijing General Research Institute of Mining and Metallurgy. This section is drafted. Guangzhou Nonferrous Metal Research Institute. Participated in the drafting of this section. Beijing General Research Institute of Mining and Metallurgy, tin mining flash-antimony industry limited liability company, limited Hunan Chenzhou Mining shares the company. The main drafters of this section. Dai Fengying, Mai Libi, Liutian Ping, Chen Geng Temple, Tan Wenjun, Ye Fangfang, Yindong Xia, Song should ball, Zhang Min. Methods for chemical analysis of antimony concentrates Part 14. Determination of silver content Flame Atomic Absorption Spectrometry

1 Scope

YS/T 556 This part provides for antimony concentrate Determination of silver content. This section applies to the determination of antimony concentrate in silver content. Determination of the range of 10.00g/t ~ 500.00g/t.

2 Method summary

Samples with hydrochloric acid, nitric acid dissolved, except hydrobromic volatile antimony in hydrochloric acid medium, with air - acetylene flame atomic absorption spectrometer wave The absorbance measured at 328.1nm long silver, the standard curve method to calculate the amount of silver.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. 3.1 hydrochloride (ρ1.19g/mL). Nitrate 3.2 (ρ1.42g/mL). 3.3 nitric acid (11). 3.4 hydrobromide (ρ1.42g/mL). 3.5 mixed acid. 3 vol hydrochloric acid (3.1) with 1 volume of nitric acid (3.2) and mixed. 3.6 silver standard solution. 3.6.1 Silver standard stock solution. Weigh 0.5000g metallic silver (wAg≥99.95%) placed in 150mL beaker, add 50mL nitrate Acid (3.3), cover sheet pan, over low heat until completely dissolved, remove, cool. The brown solution was transferred to 500mL volumetric flask, dilute with water to Volume, and mix. This silver-containing solution 1mL 1mg. 3.6.2 Silver standard solution. Pipette 10.00mL silver standard stock solution (3.6.1) in 100mL brown flask, add 5mL Nitric acid (3.2), dilute to the mark and mix. This solution 1mL silver-containing 100μg.

4 Instrument

Atomic absorption spectrometer, with a silver hollow-cathode lamp. Under optimum working conditions for those who can reach the following indicators can be used. --- Sensitivity. characteristic concentration was 0.07μg/mL. --- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed the average absorbance of 1.0%; The lowest concentration of standard solution used (instead of "zero" concentration of the solution) absorbance measured 10 times, and the standard deviation should not exceed the maximum concentration 0.5% of the mean absorbance of standard solution. --- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment Ratio of not less than 0.7.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 556.14-2011_English be delivered?

Answer: Upon your order, we will start to translate YS/T 556.14-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 556.14-2011_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 556.14-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.