SN/T 3510-2013 PDF EnglishUS$180.00 · In stock · Download in 9 seconds  
  SN/T 3510-2013: Determination of arsenic, cadmium, copper, nickel, lead, zinc in lead ore for import and export. Inductively coupled plasma atomic emission spectrometric method Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid 
 Similar standardsSN/T 3510-2013: Determination of arsenic, cadmium, copper, nickel, lead, zinc in lead ore for import and export. Inductively coupled plasma atomic emission spectrometric method---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/SNT3510-2013 SN ENTRY & EXIT INSPECTION & QUARANTINE STANDARD Determination of arsenic, cadmium, copper, nickel, lead, zinc in lead ore for import and export - Inductively couple plasma atomic emission spectrometric method Issued on. MARCH 01, 2013 Implemented on. SEPTEMBER 16, 2013 Issued by. General Administration of Quality Supervision Inspection and Quarantine of PRC Table of ContentsForeword... 3 1 Scope... 4 2 Normative references... 4 3 Method summary... 5 4 Reagent... 5 5 Instrument... 5 6 Specimen... 5 7 Analytical procedures... 6 8 Calculation of analytical results... 6 9 Precision... 7 Appendix A (Normative) Standard curve series... 8 Appendix B) (Informative) Instrument analysis conditions and element detection limits... 9ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by and shall be under the jurisdiction of the National Certification and Accreditation Administration Committee. Drafting organization of this standard. Alashankou Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China, Xinjiang Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China, Guangdong Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China, Hengyang Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China. The main drafters of this standard. He Guoqing, Lv Xinming, Reziwan, Wang Linlin, Zhong Zhiguang, Zhao Jingjing, Zhang Jinlong, Wang Dong, Mou Kun. Determination of arsenic, cadmium, copper, nickel, lead, zinc in lead ore for import and export - Inductively couple plasma atomic emission spectrometric method1 ScopeThis standard specifies the method for the determination of arsenic, cadmium, copper, nickel, lead, zinc in lead ores for import and export by inductively coupled plasma atomic emission spectrometry. This standard applies to the determination of arsenic, cadmium, copper, nickel, lead, zinc content in lead ores for import and export. The measurement range of each element is as shown in Table 1. Table 1 -- Measurement range of each element2 Normative referencesThe following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard. GB/T 602 Chemical reagent - Preparations of standard solutions for impurity GB/T 6379.2 Accuracy (trueness and precision) of measurement methods and results - Part 2.Basic method for the determination of repeatability and reproducibility of a standard measurement method GB/T 6682 Water for analytical laboratory use - Specification and test methods Element Mass fraction, % Element Mass fraction, %3 Method summaryThe sample was dissolved by acid dissolution method. The element emission intensity was measured by plasma emission spectrometer.4 ReagentUnless otherwise specified, the reagents used are all analytical reagents and above; the water is grade-2 water that meets the requirements of GB/T 6682. 4.1 Hydrochloric acid (ρ = 1.19 g/mL). 4.2 Nitric acid (ρ = 1.42 g/mL). 4.3 Nitric acid (1 + 9). 4.4 Lead standard stock solution. Accurately weigh 8.00 g of lead nitrate; use 400 mL of nitric acid (4.3) to dissolve it; transfer it into a 1000 mL volumetric flask; dilute to the mark; 1 mL of this solution contains 5 mg of lead. 4.6 Mixed standard solution. Pipette each element standard stock solution (4.5) into a 100 mL volumetric flask; use nitric acid (4.3) to dilute it to the mark; mix well. The amount of each tested element in 1 mL of this solution is as shown in Appendix A.5 Instrument5.1 Inductively coupled plasma atomic emission spectrometer.6 SpecimenThe specimen is passed through a 149 μm screen and dried in an oven at 60 °C for 4 hours; then placed in a desiccator to cool to room temperature to prepare for use.7 Analytical procedures7.1 Pre-treatment of samples Weigh about 0.2 g of sample, accurate to 0.0001 g. Place it in a 250 mL beaker. Use a small amount of water to wet it. Add 10 mL of hydrochloric acid (4.1). Leave it at room temperature for about 30 min. 7.2 Determination 7.2.1 The analytical line is as shown in Table 2. 7.2.3 Introduce the sample solution to be tested into the plasma in turn, to respectively measure the spectral intensity at the analytical line of each tested element.8 Calculation of analytical resultsCalculate the mass fraction of the measured element according to formula (1); the value is expressed in %.9 Precision8 laboratories conduct method precision tests on 7 levels of samples and perform statistics in accordance with GB/T 6379.2.The results are as shown in Table 3. SN/T 3510-2013 SN ENTRY & EXIT INSPECTION & QUARANTINE STANDARD Determination of arsenic, cadmium, copper, nickel, lead, zinc in lead ore for import and export - Inductively couple plasma atomic emission spectrometric method Issued on. MARCH 01, 2013 Implemented on. SEPTEMBER 16, 2013 Issued by. General Administration of Quality Supervision Inspection and Quarantine of PRCTable of ContentsForeword... 3 1 Scope... 4 2 Normative references... 4 3 Method summary... 5 4 Reagent... 5 5 Instrument... 5 6 Specimen... 5 7 Analytical procedures... 6 8 Calculation of analytical results... 6 9 Precision... 7 Appendix A (Normative) Standard curve series... 8 Appendix B) (Informative) Instrument analysis conditions and element detection limits... 9ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by and shall be under the jurisdiction of the National Certification and Accreditation Administration Committee. Drafting organization of this standard. Alashankou Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China, Xinjiang Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China, Guangdong Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China, Hengyang Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China. The main drafters of this standard. He Guoqing, Lv Xinming, Reziwan, Wang Linlin, Zhong Zhiguang, Zhao Jingjing, Zhang Jinlong, Wang Dong, Mou Kun. Determination of arsenic, cadmium, copper, nickel, lead, zinc in lead ore for import and export - Inductively couple plasma atomic emission spectrometric method1 ScopeThis standard specifies the method for the determination of arsenic, cadmium, copper, nickel, lead, zinc in lead ores for import and export by inductively coupled plasma atomic emission spectrometry. This standard applies to the determination of arsenic, cadmium, copper, nickel, lead, zinc content in lead ores for import and export. The measurement range of each element is as shown in Table 1. Table 1 -- Measurement range of each element2 Normative referencesThe following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard. GB/T 602 Chemical reagent - Preparations of standard solutions for impurity GB/T 6379.2 Accuracy (trueness and precision) of measurement methods and results - Part 2.Basic method for the determination of repeatability and reproducibility of a standard measurement method GB/T 6682 Water for analytical laboratory use - Specification and test methods Element Mass fraction, % Element Mass fraction, %3 Method summaryThe sample was dissolved by acid dissolution method. The element emission intensity was measured by plasma emission spectrometer.4 ReagentUnless otherwise specified, the reagents used are all analytical reagents and above; the water is grade-2 water that meets the requirements of GB/T 6682. 4.1 Hydrochloric acid (ρ = 1.19 g/mL). 4.2 Nitric acid (ρ = 1.42 g/mL). 4.3 Nitric acid (1 + 9). 4.4 Lead standard stock solution. Accurately weigh 8.00 g of lead nitrate; use 400 mL of nitric acid (4.3) to dissolve it; transfer it into a 1000 mL volumetric flask; dilute to the mark; 1 mL of this solution contains 5 mg of lead. 4.6 Mixed standard solution. Pipette each element standard stock solution (4.5) into a 100 mL volumetric flask; use nitric acid (4.3) to dilute it to the mark; mix well. The amount of each tested element in 1 mL of this solution is as shown in Appendix A.5 Instrument5.1 Inductively coupled plasma atomic emission spectrometer.6 SpecimenThe specimen is passed through a 149 μm screen and dried in an oven at 60 °C for 4 hours; then placed in a desiccator to cool to room temperature to prepare for use.7 Analytical procedures7.1 Pre-treatment of samples Weigh about 0.2 g of sample, accurate to 0.0001 g. Place it in a 250 mL beaker. Use a small amount of water to wet it. Add 10 mL of hydrochloric acid (4.1). Leave it at room temperature for about 30 min. 7.2 Determination 7.2.1 The analytical line is as shown in Table 2. 7.2.3 Introduce the sample solution to be tested into the plasma in turn, to respectively measure the spectral intensity at the analytical line of each tested element.8 Calculation of analytical resultsCalculate the mass fraction of the measured element according to formula (1); the value is expressed in %.9 Precision8 laboratories conduct method precision tests on 7 levels of samples and perform statistics in accordance with GB/T 6379.2.The results are as shown in Table 3. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of SN/T 3510-2013 be delivered?Answer: The full copy PDF of English version of SN/T 3510-2013 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of SN/T 3510-2013_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 3510-2013_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- SN/T 3510-2013 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of SN/T 3510-2013?A step-by-step guide to download PDF of SN/T 3510-2013_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "SN/T 3510-2013". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9  |