YS/T 281.19-2011 English PDFUS$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 281.19-2011: Methods for chemical analysis of cobalt. Part 19: Determination of calcium, magnesium manganese, iron, cadmium, zinc content. Inductively coupled plasma atomic emission spectrometry Status: Valid
Basic dataStandard ID: YS/T 281.19-2011 (YS/T281.19-2011)Description (Translated English): Methods for chemical analysis of cobalt. Part 19: Determination of calcium, magnesium manganese, iron, cadmium, zinc content. Inductively coupled plasma atomic emission spectrometry Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H13 Classification of International Standard: 77.120.70 Word Count Estimation: 8,823 Date of Issue: 2011-12-20 Date of Implementation: 2012-07-01 Regulation (derived from): ?MIIT Announcement 2011 No.43 Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the cobalt calcium, Determination of zinc content, magnesium, manganese, iron, cadmium. This section applies to cobalt calcium, Determination of zinc content, magnesium, manganese, iron, cadmium. Measuring range in Table 1. YS/T 281.19-2011: Methods for chemical analysis of cobalt. Part 19: Determination of calcium, magnesium manganese, iron, cadmium, zinc content. Inductively coupled plasma atomic emission spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of cobalt.Part 19. Determination of calcium, magnesium manganese, iron, cadmium, zinc content.Inductively coupled plasma emission emission ICS 77.120.70 H13 People's Republic of China Nonferrous Metals Industry Standard Cobalt chemical analysis method Part 19. determination of calcium, magnesium, manganese, iron, cadmium and zinc Inductively Coupled Plasma Atomic Emission Spectrometry Part 19. Determination ofcalcium, magnesiummanganese, iron, cadmium, 2011-12-20 release 2012-07-01 Implementation Issued by the Ministry of Industry and Information Technology of the People's Republic of China ForewordYS/T 281 "cobalt chemical analysis method" is divided into the following 20 parts. Part 1. Determination of iron content - Sulfosalicylic acid spectrophotometric method Part 2. Determination of aluminum content - Chromazu S spectrophotometric method Part 3. Determination of silicon content - Molybdenum blue spectrophotometric method Part 4. Determination of arsenic content - Molybdenum blue spectrophotometric method - Part 5. Determination of phosphorus content - Molybdenum blue spectrophotometric method Part 6. Determination of magnesium content - Flame atomic absorption spectrometric method - Part 7. Determination of zinc content - Flame atomic absorption spectrometric method Part 8. Determination of cadmium content - Flame atomic absorption spectrometric method Part 9. Determination of lead content - Flame atomic absorption spectrometric method Part 10. Determination of nickel content - Flame atomic absorption spectrometric method - Part 11. Determination of copper and manganese - Flame atomic absorption spectrometric method - Part 12. Determination of arsenic, antimony, bismuth, tin and lead - Electrothermal atomic absorption spectrometry - Part 13. Determination of sulfur content - High frequency induction furnace combustion infrared absorption method - Part 14. Determination of carbon content - High frequency induction furnace combustion infrared absorption method - Part 15. Determination of arsenic, antimony and bismuth - Hydride generation - atomic fluorescence spectrometry - Part 16. Determination of the amount of arsenic, cadmium, copper, zinc, lead, bismuth, tin, antimony, silicon, manganese, iron, nickel, aluminum and magnesium. Spectrum method - Part 17. Determination of aluminum, manganese, nickel, copper, zinc, cadmium, tin, antimony, lead and bismuth inductively coupled plasma mass spectrometry - Part 18. Determination of sodium content - Flame atomic absorption spectrometric method - Part 19. Determination of calcium, magnesium, manganese, iron, cadmium and zinc - Inductively coupled plasma emission spectrometric method - Part 20. Determination of the amount of oxygen - Infrared absorption method This section is part 19 of YS/T 281. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part of the National Nonferrous Metals Standardization Technical Committee (SAC/TC243) proposed and centralized. This standard is responsible for drafting units. Jinchuan Group Co., Ltd., Beijing Mining and Metallurgy Research Institute. This part is responsible for drafting units. Beijing Nonferrous Metals Research Institute, Shenzhen Green US High-tech Co., Ltd. This part participates in the drafting unit. Beijing Mining and Metallurgy Research Institute, Jinchuan Group Co., Ltd., Jiangsu Kailike Cobalt Industry Co., Ltd., Yingde Jia Na Metal Technology Co., Ltd. This part of the main drafters. Li Na, Zhang Xiang, Liu Ying, Xu Kaihua, Tong Jian, Yan pear, Feng Xianjin, Meng Dejun, Lv Qingcheng, Wu Yigen, Wu Chi- Luo Yueying. Cobalt chemical analysis method Part 19. determination of calcium, magnesium, manganese, iron, cadmium and zinc Inductively Coupled Plasma Atomic Emission Spectrometry WARNING. Personnel using this standard should have experience working in a regular laboratory. This standard does not indicate all possible security issues. Make It is the responsibility of the user to take appropriate safety and health measures and to ensure compliance with the conditions set forth in the relevant national regulations.1 ScopeThis part of YS/T 281 specifies the determination of calcium, magnesium, manganese, iron, cadmium and zinc in cobalt. This part is applicable to the determination of calcium, magnesium, manganese, iron, cadmium and zinc in cobalt. The measurement range is shown in Table 1. Table 1 Determination of each element Element determination range w /% Ca 0.001 to 0.05 Mg 0.001 to 0.05 Mn 0.001 to 0.2 Fe 0.003 to 0.7 Cd 0.001 ~ 0.05 Zn 0.001 to 0.052 method summaryThe samples were dissolved in dilute nitric acid and the inductively coupled plasma emission spectrometer was used to measure calcium, magnesium, manganese, iron, cadmium, The spectral intensity of zinc is calculated according to the matrix matching working curve method.3 reagentIf no special instructions, the reagents used for the analysis of pure reagents, preparation and analysis of water are secondary distilled water or considerable purity of the experiment Room water. 3.1 metal cobalt (wCo ≥ 99.98%, impurity calcium, magnesium, manganese, iron, cadmium, zinc content of less than 0.0001%). 3.2 nitric acid (ρ = 1.42g/mL), excellent grade pure. 3.3 hydrochloric acid (ρ = 1.19g/mL), excellent grade pure. 3.4 hydrogen peroxide (ρ = 1.11g/mL), excellent grade pure. 3.5 nitric acid (1 1). 3.6 Hydrochloric acid (1 1). 3.7 Calcium standard storage solution. Weigh 2.4971g of calcium carbonate (pre-dried at 105 ℃ ~ 110 ℃ constant weight, and cooled to room temperature), set ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 281.19-2011_English be delivered?Answer: Upon your order, we will start to translate YS/T 281.19-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 281.19-2011_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 281.19-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |