| WS/T 391-2024 English PDFUS$679.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. WS/T 391-2024: Computer tomography examination procedure Status: Valid WS/T 391: Historical versions
 Basic dataStandard ID: WS/T 391-2024 (WS/T391-2024)Description (Translated English): Computer tomography examination procedure Sector / Industry: Health Industry Standard (Recommended) Classification of Chinese Standard: C05 Classification of International Standard: 11.020 Word Count Estimation: 34,377 Date of Issue: 2024-07-23 Date of Implementation: 2025-01-01 Older Standard (superseded by this standard): WS/T 391-2012 Issuing agency(ies): National Health Commission Summary: �����涨��CT���ǰ������������������Ӱ����ʾҪ����������ȫ����������ҽ�ƻ���ҽ����Ա�Ի��߽���CT��顣 WS/T 391-2012: Computer tomography examination procedure---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Computer tomography examination procedure ICS 11.020 C05 People's Republic of China health industry standards CT inspection procedures 2012-09-03 released 2013-02-01 implementation Ministry of Health of People's Republic of China released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 CT radiation protection 2 5 CT examination technology 2 5.1 brain examination 2 5.2 head and neck examination 3 5.3 chest 10 5.4 Abdomen 12 5.5 Bone and joint system 19 Appendix A (Normative) Brain perfusion examination 25 Appendix B (Normative) Chest low-dose CT examination 27 References 29 ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed by the Ministry of Health Medical Services Standards Committee. This standard was drafted. First Affiliated Hospital of China Medical University, Ministry of Health Hospital Management Institute, Guangdong Provincial People's Hospital, Capital Medical Beijing Tongren Hospital Affiliated to the University, Affiliated Hospital of Qingdao University Medical College, Changzheng Hospital of the Second Military Medical University, Beijing Capital Medical University Affiliated Day Altar hospital The main drafters of this standard. Tsui Hark, Liang Changhong, Yu Zonghe, Wang Zhen Chang, Xu Wenjian, Liu Shiyuan, Gao Peiyi, Chen Haisong, Ren Ke, Fan Guoguang, Zhang Lina, Wang Qiang, Li Songbai, Li Shu, Gao Zhenlong, Sun Wenge. CT inspection procedures1 ScopeThis standard specifies the preparation before CT examination, technical methods, procedures and video display requirements. This standard applies to all levels of medical institutions at all levels of medical personnel on the subject for CT examination.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GBZ 179 Radiological protection of medical exposure to the basic requirements3 Terms and definitionsThe following terms and definitions apply to this document. 3.1 Window width windowwidth Human tissue CT range of.2000 indexing, but the human eye can only be resolved generally 16 grayscale. Window width refers to the image of 16 gray-scale Including the range of CT values within the range of CT values are shown in different analog grayscale, CT values ?? were higher than this range of organizations were significantly Is shown as white, and tissues with CT values below this range are displayed in black. 3.2 Windowlevel Window center The center of the window, the general should choose to observe the CT value of the organization as the center. The level of the window will affect the brightness of the image and improve the window level The image is black and the window is whitened. 3.3 Artifact artifact In the process of scanning or information processing, due to one or more reasons the human body does not exist and the image shows Various types of images come from, including motion artifacts, high-density artifacts and machine fault artifacts. Artifacts affect image quality, sweep Should be identified when the description of the cause, try to avoid, diagnosis should be noted and lesion phase identification. 3.4 Partial volume effect partialvolumeeffect When two or more substances with different densities are contained in the same scanning plane, the measured CT values are the average values of them and they can not be accurately reflected In any kind of material CT value, this phenomenon is called partial volume effect. In the CT scan, where less than the thickness of the lesion, the CT value by Thickness of the other tissues within the influence of the measured CT value can not represent the true CT value of the lesion. as in the high-density tissue smaller low-density Lesions, the CT value is high; the other hand, in the low-density tissue of smaller high-density lesions, the CT value is low. 3.5 Flat plainscan Normal or non-contrast scan with non-contrast scan No contrast enhancement or contrast scan. Scanning orientation and more use of cross-sectional surface, head and face examination of head and face lesions can sometimes be used ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of WS/T 391-2024_English be delivered?Answer: Upon your order, we will start to translate WS/T 391-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of WS/T 391-2024_English with my colleagues?Answer: Yes. The purchased PDF of WS/T 391-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version WS/T 391-2024?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version WS/T 391-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |