Standard ID | WS 399-2023 (WS399-2023) | Description (Translated English) | Standard for blood storage | Sector / Industry | Health Industry Standard | Classification of International Standard | 11.020 | Word Count Estimation | 8,816 | Date of Issue | 2023-09-05 | Date of Implementation | 2024-09-01 | Summary | This standard specifies requirements for blood storage facilities, storage conditions and shelf life. This standard applies to blood storage in general blood stations and medical institutions. |
WS 399-2012
Standards for blood storage
ICS 11.020
C05
People's Republic of China health industry standards
Blood storage requirements
Posted on.2012-12-03
2013-06-01 Implementation
Ministry of Health of People's Republic of China released
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
The standard 4.1.7 for the recommended terms, the rest are mandatory terms.
This standard proposed by the Ministry of Health Blood Standard Professional Committee.
This standard is mainly drafted by. Zhejiang Provincial Blood Center, Shanghai Blood Center, Fujian Provincial Blood Center, Beijing Red Cross blood
center.
The main drafters of this standard. Yan force line, Meng Zhonghua, money open, clothing plum, Guo Yongjian, Wang Hongjie.
Blood storage requirements
1 Scope
This standard specifies the blood storage requirements.
This standard applies to blood banks and medical institutions in general blood storage.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
WS/T 203 commonly used terms in blood transfusion medicine
3 Terms and definitions
WS/T 203 as defined by the following terms and definitions apply to this document.
3.1
Storage device storagedevice
Instrument or device for storing blood.
3.2
Save period storageperiod
The longest shelf life of blood suitable for human infusion under suitable conditions.
3.3
Quarantine isolation
Disqualified, to be seized, quality inspection, scrapped and other blood and qualified blood, and stored in a specific area, set a clear prompt identification (calculated
Machine information and kind), to eliminate the confusion between the physical and the physical, the physical and the information, the information and the information.
3.4
Closed system closedsystem
Disposable plastic blood bag system, the contents of the separation, packaging and other disposal process and the system completely blocked the external environment.
Aseptic catheter connector will be a number of closed system sterile high-frequency heat synthesis of new systems, and check the connection is correct, the new system is still
For the closed system.
3.5
Open system opensystem
Closed system in the process of separation of blood such as the process was opened, exposed to the local 100 cleanliness of the environment and then closed a one-time
Plastic blood bag system.
3.6
Frozen plasma frozenplasma
Physiological methods are used to separate and freeze the blood plasma in solid form during the lifetime of the whole blood or from fresh frozen plasma
After leaving the cryoprecipitate coagulation factor will be the remaining part of the solidified frozen blood, or fresh frozen plasma one year after the expiration of the plasma.
......
|