SN/T 3599-2013 PDF English

Price & Delivery

US$419.00 · In stock · Download in 9 seconds
SN/T 3599-2013: Determination of organic oxygenate compounds and benzene content in gasoline. Two-dimensional gas chromatography using a heart-cutting system
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Std IDVersionUSDBuyDeliver [PDF] inTitle (Description)
SN/T 3599-2013English419 Add to Cart 3 days [Need to translate] Determination of organic oxygenate compounds and benzene content in gasoline. Two-dimensional gas chromatography using a heart-cutting system

Click to Preview a similar PDF

Basic data

Standard ID SN/T 3599-2013 (SN/T3599-2013)
Description (Translated English) Determination of organic oxygenate compounds and benzene content in gasoline. Two-dimensional gas chromatography using a heart-cutting system
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard E31
Classification of International Standard 75.160.20
Word Count Estimation 16,113
Quoted Standard GB/T 1884; SH/T 0604; SN/T 2383
Adopted Standard EN 13132-2000, NEQ; EN 12177-2000, NEQ
Regulation (derived from) National quality recognition (2013), No. 464; industry standard filing Notice No. 1 of 2014 (No. 169 overall)
Issuing agency(ies) General Administration of Customs
Summary This standard specifies the unleaded gasoline oxygenates, total organic content of oxygen bonded to two-dimensional center and cut benzene content by gas chromatographic method. This standard applies to final boiling point of not more than 220C��C unleaded

SN/T 3599-2013: Determination of organic oxygenate compounds and benzene content in gasoline. Two-dimensional gas chromatography using a heart-cutting system





---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of organic oxygenate compounds and benzene content in gasoline. Two-dimensional gas chromatography using a heart-cutting system People's Republic of China Entry-Exit Inspection and Quarantine Standards Determination of organic oxygenate in gasoline and benzene content Dimensional heart-cutting Gas Chromatography Issued on. 2013-08-30 2014-03-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The reference to the standard EN13132.2000 "Liquid petroleum products measured unleaded gasoline unleaded organic compounds and total organic compounds Fixed column switching gas chromatography "and EN12177.2000" Liquid petroleum products unleaded gasoline benzene content by gas chromatography. " This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard was drafted. People's Republic of China Shanghai Entry-Exit Inspection and Quarantine Bureau, People's Republic of China Liaoning Entry-Exit Inspection and Quarantine Bureau. The main drafters. Zhang Jidong, Qiu Feng, Shao Min, Zhang Kai, fees Xudong, Sunyan Wei, Wei Yufeng, Wang Wenqing. Determination of organic oxygenate in gasoline and benzene content Dimensional heart-cutting Gas Chromatography

1 Scope

This standard specifies the unleaded gasoline oxygenates, total organically bound oxygen content and benzene content of the two-dimensional gas chromatography center cut test methods. This standard applies to not more than 220 ℃ unleaded gasoline oxygenates final boiling point, with a total organically bound oxygen content and benzene content Measurement, single measurement range of organic-containing oxide 0.17% to 15% (by mass), the maximum measuring range of the total organically bound oxygen content 3.7% (mass fraction), the measurement range of the benzene content of 0.05% to 6% (volume fraction).

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 1884 crude oil and liquid petroleum products - Laboratory determination of density (density meter method) SH/T 0604 crude oil and petroleum products densitometry (U-shaped vibrating tube method) SN/T 2383 liquid chemicals - Determination of density and relative density digital density meter method

3 Method summary

Benzene in gasoline and oxygenate first first capillary column separation, and then one by one through the center of the cutting system is switched to a second root color The column further separated into the components after the separation of the flame ionization detector for detection. NOTE. Two-dimensional gas chromatography center cutting guide in Appendix A.

4 Reagents

4.1 gases. hydrogen, helium or nitrogen content of greater than 99.999%, free of hydrocarbons. 4.2 oxygenated organic compounds include. methanol, ethanol, n-propanol, isopropanol, n-butanol, sec-butanol, tert-butanol, isobutanol, amyl alcohol, methyl Tert-butyl ether, methyl tert-amyl ether, ethyl t-amyl ether, acetone, methyl ethyl ketone, ethyl tertiary butyl ether, etc., all of the organic-containing sample used for the preparation of calibration Purity oxygen compound of not less than 99.0% (mass fraction). 4.3 Benzene. not less than 99.0% purity (mass fraction). 4.4 solvent. n-heptane recommended gasoline or benzene and an organic oxygen-containing compound, a solvent component to be tested or may not contain an internal standard. 4.5 internal standard. an internal standard is recommended to use methyl isobutyl ketone. When the sample itself contains methyl isobutyl ketone, it can be used similar to other volatile And a content of not less than 99.0% (by mass) of the organic oxygen-containing compound (e.g. 1,2-dimethoxyethane) as the internal standard.

5 Instruments

5.1 GC 5.1.1 Gas chromatography. with a column switching valve (center cutting system that Deansswitching system), flame ionization detector (FID), Cheng
...

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 3599-2013_English be delivered?


Answer: Upon your order, we will start to translate SN/T 3599-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 3599-2013_English with my colleagues?


Answer: Yes. The purchased PDF of SN/T 3599-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
Refund Policy Privacy Policy Terms of Service