Path:
Home >
SN/T >
Page81 > SN/T 3531-2013
Price & Delivery
US$289.00 · In stock · Download in 9 secondsSN/T 3531-2013: Evaluation method for standby and off mode electric power consumption of electrical and electronic appliances for import and export
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| SN/T 3531-2013 | English | 289 |
Add to Cart
|
3 days [Need to translate]
|
Evaluation method for standby and off mode electric power consumption of electrical and electronic appliances for import and export
|
Click to Preview a similar PDF
Basic data
| Standard ID | SN/T 3531-2013 (SN/T3531-2013) |
| Description (Translated English) | Evaluation method for standby and off mode electric power consumption of electrical and electronic appliances for import and export |
| Sector / Industry | Commodity Inspection Standard (Recommended) |
| Word Count Estimation | 11,112 |
| Quoted Standard | GB/T 2828.1-2003; IEC 62301-2005; European Commission Regulation (EC) NO 1275/2008 |
| Regulation (derived from) | ?AQSIQ About publishing 2013 First Batch 179-items Entry-Exit Inspection and Quarantine industry standard Announcement; Industry-Standard-Filing Announcement 2013 No. 9 (Total No. 165) |
| Issuing agency(ies) | General Administration of Customs |
| Summary | This standard specifies the general requirements for electrical and electronic products standby and shutdown power consumption evaluation methods. Electrical and electronic products for standby and off -power limit requirements proposed, test methods and |
Similar standards
SN/T 5268|
SN/T 3531-2013: Evaluation method for standby and off mode electric power consumption of electrical and electronic appliances for import and export
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Evaluation method for standby and off mode electric power consumption of electrical and electronic appliances for import and export
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Import and export of electrical and electronic products standby and
Evaluation of Power Shutdown
Issued on. 2013-03-01
2013-09-16 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard standby and shutdown power requirements equivalent to Commission Regulation (EC) 2008 the first phase requirements No1257 /.
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. People's Republic of China Jiangsu Entry-Exit Inspection and Quarantine Bureau, People's Republic of China Fujian Entry-Exit Inspection and
Quarantine Bureau.
The main drafters of this standard. Yu Jianfeng, Qian Jianming, Tian Peng, Lin Miao, SUN Hao Ming, Mao Ming Ming, over the peak, Dong Jun.
Import and export of electrical and electronic products standby and
Evaluation of Power Shutdown
1 Scope
This standard specifies the general requirements for electrical and electronic products standby and off power evaluation method, for electrical and electronic products, standby and off
Power proposed limit requirements, test methods and inspection rules.
This standard applies to rated voltage not exceeding 250V, when connected to the power grid work, electrical and electronic products for end users. This standard
Involved in electrical and electronic products especially household appliances, home (office) information technology equipment and recreational equipment, see Appendix A.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2828.1-2003 Sampling procedures for inspection - Part 1. by acceptance quality limit (AQL) retrieval batch test sample
plan
IEC 62301.2005 Household appliances standby power measurement
Commission Regulation (EC) No1275/2008, on the ecology on household and office electrical and electronic equipment in standby and off power set
Design requirements, the implementation of the European Parliament and Council Directive 2005/32/EC
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Inspection Lot inspectionlot
For the implementation of import and export inspection and collection of contract, type and apply the test of time to distinguish a certain number of products, referred to as batch.
3.2
Shutdown mode offmode
The appliance connected to the power, but does not provide a device status of any function, then the device is the minimum energy state.
Note. If only the shutdown status indicator (light emitting diode) are also considered off mode.
3.3
Standby mode standbymode
The appliance connected to the power supply, only continue to provide the restart information or status display function without state to perform its primary function.
Note. The start function is through the remote control, internal sensor or clock enable state switching devices in order to achieve the main function of providing a functional purpose. letter
Information or status display refers to display device status information or functionality, but this feature can not be the main function of the device.
3.4
Restart function reactivation
One kind by remote switch, including remote control, internal sensor and a timer activation of other modes (including activation mode), which provided
Enter into a prepared provide additional functionality (including the main function) of the operational status of the function.
...