Home Cart Quotation Policy About-Us
www.ChineseStandard.net
Database: 221870 (13 Apr 2026)
SEARCH
Path: Home > SN/T > Page81 > SN/T 3516-2013

SN/T 3516-2013 PDF English

Price & Delivery

US$189.00 · In stock · Download in 9 seconds
SN/T 3516-2013: Determination of lead iron cadmium copper tin antimony in high-purity zinc. Inductively coupled plasma mass spectrometry
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Std IDVersionUSDBuyDeliver [PDF] inTitle (Description)
SN/T 3516-2013English189 Add to Cart 3 days [Need to translate] Determination of lead iron cadmium copper tin antimony in high-purity zinc. Inductively coupled plasma mass spectrometry

Click to Preview a similar PDF

Basic data

Standard ID SN/T 3516-2013 (SN/T3516-2013)
Description (Translated English) Determination of lead iron cadmium copper tin antimony in high-purity zinc. Inductively coupled plasma mass spectrometry
Sector / Industry Commodity Inspection Standard (Recommended)
Word Count Estimation 7,744
Quoted Standard GB/T 602; GB/T 6682-2008
Regulation (derived from) ?AQSIQ About publishing 2013 First Batch 179-items Entry-Exit Inspection and Quarantine industry standard Announcement; Industry-Standard-Filing Announcement 2013 No. 9 (Total No. 165)
Issuing agency(ies) General Administration of Customs
Summary This standard provides high-purity zinc lead, iron, cadmium, copper, tin, antimony inductively coupled plasma mass spectrometry (ICP-MS) was measured. This standard applies to high-purity zinc lead, determination of antimony, iron, cadmium, copper, tin.

SN/T 3516-2013: Determination of lead iron cadmium copper tin antimony in high-purity zinc. Inductively coupled plasma mass spectrometry




---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of lead iron cadmium copper tin antimony in high-purity zinc. Inductively coupled plasma mass spectrometry People's Republic of China Entry-Exit Inspection and Quarantine Standards Lead, iron, cadmium, copper, tin, antimony in high purity zinc Inductively Coupled Plasma Mass Spectrometry Issued on. 2013-03-01 2013-09-16 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard was drafted. People's Republic of China Guangdong CIQ. The main drafters of this section. Zhao Quan, Zhang Zhuo, Xiaoda Hui, Zhou Xiaoli, ZHOU Ming-hui, Di Cuiping, Zheng Jianguo. Lead, iron, cadmium, copper, tin, antimony in high purity zinc Inductively Coupled Plasma Mass Spectrometry

1 Scope

This standard provides high purity zinc lead, iron, cadmium, copper, tin, antimony inductively coupled plasma mass spectrometry (ICP-MS) was measured. This standard applies to lead, iron, cadmium, copper, tin, antimony in high purity zinc, the detection limit of the elements shown in Table 1. Table 1 standard detection limit of the elements Element Pb Fe Cd Cu Sn Sb The detection limit/(mg/kg) 0.001 0.5 0.002 0.02 0.001 0.001

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. Preparation of standard solution of GB/T 602 Determination of impurities in chemical reagents Laboratory use specifications and test methods GB/T 6682-2008 Analysis

3 Method summary

High purity zinc samples after digestion nitric acid pretreatment, using ICP-MS method for the determination of lead in high purity zinc, iron, cadmium, copper, tin and antimony.

4 Reagents and materials

In addition to this section use the gifted class pure reagents, test water should be consistent with a water GB/T 6682-2008 stipulated. 4.1 nitric acid (ρ = 1.19g/mL). 4.2 nitric acid solution (11). 4.3 nitric acid solution (119). 4.4 lead, iron, cadmium, copper, tin, antimony standard stock solution. 1000μg/mL. 4.5 internal standard. 45Sc, 115In, 209Bi standard solution, 1μg/mL. 4.6 internal standard solution. an internal standard (4.5) diluted 100 times to give 10μg/L. 4.7 purity argon gas (purity greater than 99.999%). 5. Apparatus 5.1 Inductively Coupled Plasma Mass Spectrometer. Instrument parameters and conditions of use, see Appendix A.
...

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 3516-2013_English be delivered?


Answer: Upon your order, we will start to translate SN/T 3516-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 3516-2013_English with my colleagues?


Answer: Yes. The purchased PDF of SN/T 3516-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
Refund Policy Privacy Policy Terms of Service