Home Cart Quotation Policy About-Us
www.ChineseStandard.net
Database: 221870 (13 Apr 2026)
SEARCH
Path: Home > SN/T > Page38 > SN/T 3469.5-2014

SN/T 3469.5-2014 PDF English

Price & Delivery

US$189.00 · In stock · Download in 9 seconds
SN/T 3469.5-2014: Determination of platinum and palladium in imported sintered copper material of coarse smelting. Inductively coupled plasma mass spectrometry
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Std IDVersionUSDBuyDeliver [PDF] inTitle (Description)
SN/T 3469.5-2014English189 Add to Cart 3 days [Need to translate] Determination of platinum and palladium in imported sintered copper material of coarse smelting. Inductively coupled plasma mass spectrometry

Click to Preview a similar PDF

Basic data

Standard ID SN/T 3469.5-2014 (SN/T3469.5-2014)
Description (Translated English) Determination of platinum and palladium in imported sintered copper material of coarse smelting. Inductively coupled plasma mass spectrometry
Sector / Industry Commodity Inspection Standard (Recommended)
Classification of Chinese Standard H10
Classification of International Standard 77.040.30
Word Count Estimation 7,734
Date of Issue 4/9/2014
Date of Implementation 11/1/2014
Quoted Standard GB/T 602; GB/T 2007.1; GB/T 6682
Regulation (derived from) ?Industry Standard Filing Announcement 2015 No. 1 (Total number 181)
Issuing agency(ies) General Administration of Customs
Summary This Standard specifies the method of inductively coupled plasma mass spectrometry imported crude refining or sintering of platinum, palladium and copper content of the material. This section applies to import crude refining or sintered material in the de

SN/T 3469.5-2014: Determination of platinum and palladium in imported sintered copper material of coarse smelting. Inductively coupled plasma mass spectrometry





---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of platinum and palladium in imported sintered copper material of coarse smelting. Inductively coupled plasma mass spectrometry People's Republic of China Entry-Exit Inspection and Quarantine Standards Determination of imported crude copper smelting or sintered material of platinum, palladium content Inductively Coupled Plasma Mass Spectrometry Issued on. 2014-04-09 2014-11-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

SN/T 3469 is divided into six parts. --- Part 1. imports of crude refining of copper or a sintered material Determination of short iodometry; --- Part 2. imports of copper smelting or sintered material in the fluorine content - Ion selective electrode method; --- Part 3. Determination of copper material in the sulfur content of imported crude refining or sintering frequency combustion infrared absorption method; --- Part 4. Imported crude refining or sintered copper material gold, silver content determination by flame atomic absorption spectrometry; --- Part 5. Imported crude copper smelting or sintered material of platinum, palladium content by inductively coupled plasma mass spectrometry; --- Part 6. imported crude copper smelting or sintered material testing procedures. This section SN/T Section 53469 of. This section drafted in accordance with GB/T 1.1-2009 given rules. This section proposed and managed by the National Certification and Accreditation Administration Committee. This section was drafted by. People's Republic of China Tianjin Entry-Exit-Entry Inspection and Xinjiang People's Republic of China Quarantine Bureau. The main drafters of this section. Hood new, Wang Haoyun, Xiao Kui, Liu, Wang Hong, Li Quan Bin, Wang Zhaorui, Zhao Jiangyong. Determination of imported crude copper smelting or sintered material of platinum, palladium content Inductively Coupled Plasma Mass Spectrometry

1 Scope

SN/T 3469 provisions of this part of the inductively coupled plasma mass spectrometry imported crude copper smelting or sintered material of platinum, palladium content method. This section applies to imported crude refining or sintered material in the determination of copper, platinum, palladium content detection limit. Pt was 0.13μg/kg, Pd was 0.11μg/kg.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. Preparation of standard solution of GB/T 602 Determination of impurities in chemical reagents GB/T 2007.1 minerals in bulk sampling, preparation General manual sampling methods Laboratory use specifications and test methods GB/T 6682 Analysis

3 Method summary

Sample addition of hydrochloric acid, nitric acid decomposition of hypothermia after filtration through activated carbon - anion resin adsorption enrichment. Ashing activated carbon - anion tree Fat, with dilute hydrochloric acid, dissolve after capacity was measured in the plasma mass spectrometer.

4 Reagents and materials

Unless otherwise indicated in the analysis using only recognized as analytical reagents, test water standards in line with GB/T 6682 provided a Grade water. 4.1 hydrochloride (1.19g/mL). 4.2 nitrate (1.42g/mL). 4.3 Hydrofluoric acid (1.15g/mL). 4.4 with dilute hydrochloric acid (19). 4.5 platinum, palladium standard stock solution (1000μg/mL), each element standard solution used directly or formulated in accordance with national standards GB/T 602 method Reference material. 4.6 platinum, palladium mixed standard solution series. serial dilution of platinum, palladium standard stock solution elements (4.5), configured as platinum, palladium concentrations 0.00μg/L, 2.00μg/L, 5.00μg/L, 20.00μg/L, 50.00μg/L series of mixed standard solution. 4.7 Anion Exchange Resin.201 × 7 type styrenic strongly basic anion exchange resin (60 mesh to 80 mesh), with 30% (V/V) of Hydrochloric acid soak 24h, it fully swollen after the transformation, washed three times, soaked in water use. 4.8 Activated Carbon. A commercially available powdered activated carbon with 50% (V/V) hydrochloric acid, 50% (V/V) hydrofluoric acid soaking, plus a Buchner funnel suction pump After filtration, washed three times, drained, dried at 110 ℃ spare. 4.9 medium speed filter paper.
...

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 3469.5-2014_English be delivered?


Answer: Upon your order, we will start to translate SN/T 3469.5-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 3469.5-2014_English with my colleagues?


Answer: Yes. The purchased PDF of SN/T 3469.5-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
Refund Policy Privacy Policy Terms of Service