Path:
Home >
SN/T >
Page4 > SN/T 3241.4-2012
Price & Delivery
US$339.00 · In stock · Download in 9 secondsSN/T 3241.4-2012: Technical requirements for the inspection of household and similar electrical appliances for import and export. Part 4: Energy efficiency of room air conditioner
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| SN/T 3241.4-2012 | English | 339 |
Add to Cart
|
3 days [Need to translate]
|
Technical requirements for the inspection of household and similar electrical appliances for import and export. Part 4: Energy efficiency of room air conditioner
|
Click to Preview a similar PDF
Basic data
| Standard ID | SN/T 3241.4-2012 (SN/T3241.4-2012) |
| Description (Translated English) | Technical requirements for the inspection of household and similar electrical appliances for import and export. Part 4: Energy efficiency of room air conditioner |
| Sector / Industry | Commodity Inspection Standard (Recommended) |
| Classification of Chinese Standard | Y61 |
| Word Count Estimation | 13,178 |
| Quoted Standard | GB/T 7725; GB 12021.3-2010; SN/T 0002-2004; CEL-002; AS/NZS3823.1.1; AHAM.RAC-1; EN 14511-1, EN 14511-2, EN 14511-3, EN 14511 -4 using power-driven compressors for space heating and cooling liquid chillers and heat pump air conditioner |
| Regulation (derived from) | National Quality Inspection (2012) 777; industry standard filing Notice 2013 No. 4 (No. 160 overall) |
| Issuing agency(ies) | General Administration of Customs |
| Summary | This standard specifies the import room air conditioner energy efficiency requirements, testing and results of the determination. This standard applies to the use of air-cooled condenser, fully enclosed motor compressor, cooling capacity 14000W and below, |
SN/T 3241.4-2012: Technical requirements for the inspection of household and similar electrical appliances for import and export. Part 4: Energy efficiency of room air conditioner
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical requirements for the inspection of household and similar electrical appliances for import and export.Part 4. Energy efficiency of room air conditioner
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Import and export of household and similar electrical appliances test
Technical requirements Part 4. room air
Energy efficiency regulator
Part 4. Energyefficiencyofroomairconditioner
Issued on. 2012-12-12
2013-07-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
SN/T 3241 "Importers of household and similar electrical appliances test technical requirements" is divided into four parts.
--- Part 1. AC electric fans energy efficiency;
--- Part 2. automatic rice cooker energy efficiency;
--- Part 3. refrigerator energy efficiency;
--- Part 4. room air conditioner energy efficiency.
This section SN/T 3241 Part 4.
This section drafted in accordance with GB/T 1.1-2009 given rules.
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This section proposed and managed by the National Certification and Accreditation Administration Committee.
This section was drafted by. People's Republic of China Jiangsu Entry-Exit Inspection and Quarantine Bureau, the People's Republic of China Shanghai Entry-Exit Inspection and
Quarantine Bureau.
The main drafters of this section. Tao Weidong, Xu Jie, Fupei Gang, Xu Sheng, Li Min.
Import and export of household and similar electrical appliances test
Technical requirements Part 4. room air
Energy efficiency regulator
1 Scope
This section SN/T 3241 provides for import and export room air conditioner energy efficiency requirements, inspection and judgment results.
This section applies to the use of air-cooled condensers, Hermetic motor - compressors, cooling capacity in 14000W and below, the climate class
TI type is the room air conditioner energy efficiency of import and export inspection.
This section does not apply to mobile, speed-controlled, multi-type air conditioning units.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 7725 Room Air Conditioners
GB 12021.3-2010 room air conditioner energy efficiency limit value and energy efficiency rating
The basic provisions of SN/T 0002-2004 and export mechanical and electrical inspection for the inspection written
CEL-002 room air conditioner energy efficiency labeling rules
EN14511-1, EN14511-2, EN14511-3, EN14511-4 use electrically driven compressors for space heating and cooling for the air conditioning
Liquid chillers and heat pumps (Airconditioners, liquidchilingpackagesandheatpumpswithelectricalydriven
compressorsforspaceheatingandcooling)
AS/NZS3823.1.1 no duct connected to the air conditioner and heat pumps - Testing and Performance Rating (Performanceofelectrical
appliances-Airconditionersandheatpumps-Part 1.1. Non-ductedairconditionersandheatpumps-
Testingandratingfoeperformance)
AHAM.RAC-1 Room Air Conditioners (Roomairconditioners)
3 Terms and Definitions
GB 12021.3-2010, SN/T 0002 defined by the following terms and definitions apply to this document.
3.1
Sampling mode modeofsamplinginspection
According to the mandatory requirements of national technical specifications, batch import and export commodities or pumping batch conformity assessment sampling, testing and inspection.
3.2
Type Test mode modeoftypetest
According to a predetermined cycle based on the mandatory requirements of national technical specifications type testing, according to on-site inspection requirements for product pumping batch inspection
Inspection, supervision and implementation of the conformity assessment activities of the enterprise quality management system.
3.3
Compliance Verification mode modeofcomplianceverification
According to the mandatory requirements of national technical specifications, inspection certificate and inspection documents, goods are consistent with the random testing can be carried out when necessary, and real
...