SN/T 1819-2006239 Add to Cart 2 days Import and export latex medical gloves protein determination. Improved the method of Lowry Obsolete

Similar standards

YY/T 0243   HAD 002/01   HG/T 2584   

Basic data

Standard ID: SN/T 1819-2006 (SN/T1819-2006)
Description (Translated English): Import and export latex medical gloves protein determination. Improved the method of Lowry
Sector / Industry: Commodity Inspection Standard (Recommended)
Classification of Chinese Standard: G45
Classification of International Standard: 11.140; 83.140
Word Count Estimation: 6,638
Date of Issue: 2006-08-28
Date of Implementation: 2007-03-01
Quoted Standard: GB/T 6682
Adopted Standard: ASTM D5712-1999, NEQ
Regulation (derived from): ?National-accreditation-Science [2010] 50; Accreditation-Science [2014] 263; 2014- inspection and quarantine industry standard review conclusions
Issuing agency(ies): General Administration of Customs
Summary: This standard specifies the protein content of latex medical gloves in the method. This standard applies to medical gloves in latex protein content. This standard latex protein content range: 7��g/dm2 ~ 200��g/dm2.

SN/T 1819-2006: Import and export latex medical gloves protein determination. Improved the method of Lowry


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Import and export latex medical gloves protein determination.Improved the method of Lowry Book of the People's Republic of China Entry and Exit Inspection and Quarantine Determination of latex protein in medical gloves for import and export Released on.2006-08-28 2007-03-01 implementation People's Republic The General Administration of Quality Supervision, Inspection and Quarantine issued

Foreword

This standard refers to ASTM D5712-1999 "Determination of water-soluble proteins in natural rubber and its products - improved Lowry method Formulation. This standard is proposed and managed by the National Certification and Accreditation Administration. This standard was drafted. Ningbo Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China. The main drafters of this standard. Tong Lubo, Ge Xuanning. This standard is the first industry standard for entry-exit inspection and quarantine. Determination of latex protein in medical gloves for import and export

1 Scope

This standard specifies the method for determining the protein content of latex in medical gloves. This standard applies to the determination of latex protein content in medical gloves. The range of determination of latex protein content in this standard. 7μg/dm 2~200μg/dm 2.

2 Normative references

The terms in the following documents become the terms of this standard by reference to this standard. All dated references, followed by all Modifications (not including errata content) or revisions do not apply to this standard, however, parties to agreements based on this standard are encouraged to study Is it possible to use the latest version of these files? For undated references, the latest edition applies to this standard. GB/T 6682 Analytical laboratory water specifications and test methods

3 Method summary

Latex protein in medical gloves and natural rubber products can be extracted from the buffer solution and precipitated to remove soluble interferences. The Lowry method measures the absorbance at a wavelength of 750 nm from a spectrophotometer.

4 Terms and definitions

The following terms and definitions apply to this standard. 4.1 The sodium hydroxide capacity (mL) used to dissolve the sample to extract the precipitate and the sodium hydroxide used to decompose the standard ovalbumin extract The ratio of capacity (mL). Note. For example, 5mL test extract, precipitated and dissolved with 1.25mL sodium hydroxide, standard egg protein is dissolved with sodium hydroxide, and its dissolved volume is also At 1.25 mL, the dilution rate of the test extract is the same as the dilution rate of the standard curve. 4.2 Latex proteins and polypeptides from natural rubber and its products. 4.3 Quantitative detection limit LOQ The lowest protein content that can be quantitatively measured and produces accurate results. The LOQ is set to a standard deviation of 10 times.

5 instruments

5.1 Centrifuge. 5.2 Spectrophotometer. 5.3 Vortex mixer. 5.4 Micro-adjustable pipette (0.2mL ~ 5.0mL), volumetric flask (50mL, 100mL). 5.5 Polypropylene test tubes. capacities of 50 mL and 10 mL.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 1819-2006_English be delivered?

Answer: Upon your order, we will start to translate SN/T 1819-2006_English as soon as possible, and keep you informed of the progress. The lead time is typically in 9 seconds (download/delivered in 9 seconds). The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 1819-2006_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 1819-2006_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.