SN/T 1799-2006 English PDFUS$199.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 1799-2006: Determination of cobalt content in cobalt concentrate for import Status: Valid
Basic dataStandard ID: SN/T 1799-2006 (SN/T1799-2006)Description (Translated English): Determination of cobalt content in cobalt concentrate for import Sector / Industry: Commodity Inspection Standard (Recommended) Classification of Chinese Standard: D42 Classification of International Standard: 73.060 Word Count Estimation: 6,654 Date of Issue: 2006-08-28 Date of Implementation: 2007-03-01 Quoted Standard: GB/T 601; GB/T 603 Issuing agency(ies): General Administration of Customs Summary: This standard specifies the import cobalt concentrates Determination of cobalt content. This standard applies to imports of cobalt concentrate cobalt content, measurement range of 8% to 20%. SN/T 1799-2006: Determination of cobalt content in cobalt concentrate for import---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Determination of cobalt content in cobalt concentrate for import Book of the People's Republic of China Entry and Exit Inspection and Quarantine Determination of cobalt content in imported cobalt concentrate Released on.2006-08-28 2007-03-01 implementation People's Republic The General Administration of Quality Supervision, Inspection and Quarantine issued ForewordThis standard is proposed and managed by the National Certification and Accreditation Administration. This standard was drafted. Hebei Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China. The main drafters of this standard. Guo Wenlei, Yan Hong. This standard was first published Entry and exit inspection and quarantine industry standards. Determination of cobalt content in imported cobalt concentrate1 ScopeThis standard specifies the method for determining the cobalt content of imported cobalt concentrate. This standard is applicable to the determination of cobalt content in imported cobalt concentrates, with a determination range of 8% to 20%.2 Normative referencesThe terms in the following documents become the terms of this standard by reference to this standard. All dated references, followed by all Modifications (not including errata content) or revisions do not apply to this standard, however, parties to agreements based on this standard are encouraged to study Is it possible to use the latest version of these files? For undated references, the latest edition applies to this standard. Preparation of GB/T 601 chemical reagent standard titration solution Preparation of preparations and products used in GB/T 603 chemical reagent test method3 Method summaryThe sample is dissolved in perchloric acid-hydrofluoric acid-nitric acid, and cobalt is separated as a precipitate of cobalt nitronate in an acetic acid medium to which tartaric acid is added. The cobalt content was determined by EDTA standard solution titration.4 reagents and materialsUnless otherwise stated, only analytically pure reagents and distilled or deionized water or water of comparable purity were used in the analysis. 4.1 Ammonia. 4.2 Perchloric acid. 4.3 Concentrated nitric acid. 4.4 Hydrofluoric acid. 4.5 Glacial acetic acid. 4.6 Hydrochloric acid (1+1). 4.7 potassium nitrite solution A (precipitate). Weigh 50g of potassium nitrite dissolved in appropriate amount of water, add 8mL of glacial acetic acid, dilute with water to 100mL, shake well. 4.8 Potassium nitrite solution B solution (washing solution). Measure 40 mL of potassium nitrite solution A, 8 mL of glacial acetic acid, and dilute to 500 mL with water. Shake well. 4.9 Potassium carbonate solution (20%). 20 g of potassium carbonate was dissolved in 100 mL of water. 4.10 Tartaric acid solution. 100 g of tartaric acid is dissolved in 100 mL of water. 4.11 Ammonia-ammonium chloride buffer solution (pH≈10). Prepared according to GB/T 603 requirements. 4.12 0.05mol/L EDTA standard titration solution. prepared and calibrated according to GB/T 601 requirements. 4.13 Ammonium urate indicator. 0.5g of ammonium urate is added to 100g of sodium chloride, and mixed and ground. 4.14 Congo red test strips. 4.15 Filter paper. medium speed qualitative filter paper. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 1799-2006_English be delivered?Answer: Upon your order, we will start to translate SN/T 1799-2006_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of SN/T 1799-2006_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 1799-2006_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |