| SN/T 0837.3-2011 English PDFUS$159.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 0837.3-2011: Method for chemical analysis of arsenic trioside for import and export. Part 3: Determination of iron content Status: Valid SN/T 0837.3: Historical versions
 Basic dataStandard ID: SN/T 0837.3-2011 (SN/T0837.3-2011)Description (Translated English): Method for chemical analysis of arsenic trioside for import and export. Part 3: Determination of iron content Sector / Industry: Commodity Inspection Standard (Recommended) Classification of Chinese Standard: G10 Word Count Estimation: 6,654 Date of Issue: 2011-02-25 Date of Implementation: 2011-07-01 Older Standard (superseded by this standard): SN/T 0837.3-1999 Quoted Standard: GB/T 21187-2007; JB/T 9324-1999 Regulation (derived from): ?AQSIQ-Inspection [2011] 90 Issuing agency(ies): General Administration of Customs Summary: This standard specifies the out-Determination of iron content of arsenic trioxide method. This section applies to the determination of arsenic trioxide in the import and export of iron content. Measuring range: 0. 002% to 1. 0% (mass fraction). SN/T 0837.3-2011: Method for chemical analysis of arsenic trioside for import and export. Part 3: Determination of iron content---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Method for chemical analysis of arsenic trioside for import and export.Part 3. Determination of iron content People's Republic of China Entry-Exit Inspection and Quarantine Standards Instead of the SN/T 0837.3-1999 Import and export of chemical analysis of arsenic trioxide Part 3. Determination of iron content Part 3. Determinationofironcontent Issued on. 2011-02-25 2011-07-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released ForewordSN/T 0837 "Importers and chemical analysis of arsenic trioxide" series of standards is divided into four parts. Determination of Arsenic trioxide content. --- Part 1 --- Part 2. Determination of moisture content --- Part 3. Determination of iron content --- Part 4. Determination of chlorine ion content This section SN/T Section 30837 of. The partial replacement of SN/T 0837.3-1999 "Determination of arsenic trioxide in the export of iron." This portion of the SN/T 0837.3- Compared to 1999, the main changes are as follows. --- The lower limit of the measurement range from 0.001% to 0.002% or modification; --- In Chapter 6, "sample", the increased size of the requirements by deleting the content on sample preparation and preservation. Notes to modify the warning After the first on this Part; --- In Chapter 3, "Methods and Principles", the low-temperature low-temperature burning arsenic removal to removal of arsenic dissolved in hydrochloric acid; --- Flame atomic absorption spectrometry and O - phenanthroline UV spectrophotometry same parts blend together; --- In Chapter 4, "agent", the hydrochloric acid (21) instead of hydrochloric acid (11), of iron standard solution (1mg/mL) to switch to a commercial standard solution; --- In Chapter 7, "analysis step", the increase of the parallel determination requirements. In addition to the direct low-temperature burning arsenic dissolved in hydrochloric acid to lower Temperature arsenic removal. The residue was dissolved to adjust the amount of acid, so that a consistent sample and standard solution acidity; --- Will allow differential expression changed to regulate the expression of precision; --- Delete the original contents of Appendix A "atomic absorption spectrophotometer performance indicators", performance metrics defined in Chapter 5. This section proposed and managed by the National Certification and Accreditation Administration Committee. This section was drafted by. People's Republic of China Guangdong CIQ. Drafters of this section. Lu Zhenguo, Luo Yumei, Guo Seoul, Chung Pei Yu, Zhao Quan, Zhangzhen Kun, Chen Wenjie. This part of the alternative criteria previously issued as follows. --- ZBG10001-1986 Chapter 4. Determination of iron; --- SN/T 0837.3-1999. Import and export of chemical analysis of arsenic trioxide Part 3. Determination of iron content Warning. Arsenic trioxide is highly toxic chemicals, the use of this standard shall have a person experiences regular laboratory work. This standard It does not indicate a possible security problem. The user's responsibility to take appropriate safety and health practices and to ensure compliance with relevant national regulations condition.1 ScopeThis section provides a method for the import and export of iron content determination of arsenic trioxide. This section applies to the determination of arsenic trioxide and export of iron content. Measurement range. 0.002% to 1.0% (mass fraction).2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 21187-2007 atomic absorption spectrophotometer JB/T 9324-1999 Vis3 PRINCIPLE OF THE METHODSample was dissolved with hydrochloric acid, low temperature to remove arsenic chloride evaporated, the residue was dissolved with hydrochloric acid. By flame atomic absorption spectrometry or Phenanthroline spectrophotometric Spectrophotometric determination of iron content. Flame Atomic Absorption Spectrometry. air - acetylene flame at a wavelength at 248.3nm measured absorbance; phenanthroline Luo spectrophotometry method. with ascorbic acid ferric reduced to ferrous iron, an appropriate amount of ammonium acetate in the presence of divalent iron to generate Phenanthroline Orange-red complex, at the wavelength of 510nm measured absorbance.4 ReagentsUnless otherwise specified, use only analytical grade reagents and distilled or deionized water or equivalent purity. 4.1 hydrochloride (ρ1.19g/mL). 4.2 hydrochloride (11). 4.3 hydrochloride (298). 4.4 iron standard stock solution (1000μg/mL). 4.5 iron standard solution (100μg/mL). Pipette 10.00mL iron standard stock solution (4.4) in 100mL flask, add 4mL salt Acid (4.2), diluted with water to the mark. 4.6 iron standard solution (10.0μg/mL). Pipette 1.00mL iron standard stock solution (4.4) in 100mL flask, add 4mL salt Acid (4.2), diluted with water to the mark. 4.7 ammonium acetate solution (400g/L). 4.8 ascorbic acid solution (10g/L), the time is now equipped with. 4.9 Phenanthroline solution (1g/L). dissolve 0.1g Phenanthroline in 100mL of water, stored in a colored bottle, if there is color, should be re ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 0837.3-2011_English be delivered?Answer: Upon your order, we will start to translate SN/T 0837.3-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of SN/T 0837.3-2011_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 0837.3-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version SN/T 0837.3-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version SN/T 0837.3-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |