GBZ24979-2010 English PDFUS$299.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GBZ24979-2010: Performance assessment of point type smoke and/or heat fire detector Status: Valid
Basic dataStandard ID: GB/Z 24979-2010 (GB/Z24979-2010)Description (Translated English): Performance assessment of point type smoke and/or heat fire detector Sector / Industry: National Standard Classification of Chinese Standard: C81 Classification of International Standard: 13.220.20 Word Count Estimation: 13,119 Date of Issue: 2009-08-09 Date of Implementation: 2010-12-01 Quoted Standard: GB 4208-2008; GB 4715-2005; GB 4716-2005; GB/T 4718-2006 Regulation (derived from): ?National Standard Approval Announcement 2010 No.3 (Total No.158) Issuing agency(ies): Ministry of Health of the People's Republic of China Summary: This standard specifies the evaluation process and the evaluation methods point type smoke/heat detectors performance evaluation. This standard applies to point-type smoke detectors, point type heat detectors, point type smoke detectors ju composite fire for point type smoke/heat detectors performance evaluation provides the guidelines. This standard also applies to point-type smoke, point type heat, performance evaluation point type flue gas temperature composite fire detection algorithm. GBZ24979-2010: Performance assessment of point type smoke and/or heat fire detector---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Performance assessment of point type smoke and/or heat fire detector ICS 13.220.20 C81 People's Republic of China national standardization of technical guidance documents Performance Evaluation of Point Type Smoke/Temperature Detector Posted on.2010-08-09 2010-12-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Requirements 1 5 Evaluation Method 2 Appendix A (Informative) Fire Detection Performance Comprehensive Simulation Evaluation Test Platform 6 Appendix B (Normative) Wood fire 7 Appendix C (Normative) Decalin fire 8 Appendix D (Normative) Newsprint fire 9 ForewordPoint-type smoke/thermal detectors in special and complex applications under conditions of fire response, anti-interference ability and other comprehensive performance needs to be carried out Scientific evaluation to ensure the realization of fire safety goals. This guideline is for reference only. The suggestions and opinions on this technical document are directed to the standardization administration under the State Council Department reflected. Appendix B, Appendix C, Appendix D of this guidance document are normative appendices, and Appendix A is informative appendix. This instructional technical document was submitted by the Ministry of Public Security of the People's Republic of China. The guidance of technical documents by the National Standardization Technical Committee fire detection and alarm sub-technical committee (SAC/TC113/SC6) Focused. This guidance is responsible for the drafting of technical documents. Ministry of Public Security Shenyang Institute of Fire. The guidance of technical documents to participate in the drafting unit. Liaoning Provincial Public Security Fire Corps, Xi'an Sheng Purcell Electronics Co., Ltd., Gulf Security Technology Limited. The main drafters of this guidance document are Dong Wenhui, Mei Zhibin, Gongpu, Wang Zhuofu, Song Zhen, Liu Yubao, Guan Dawei, Zhang Xiongfei, Wang Ai Zhong, noble guests. Performance Evaluation of Point Type Smoke/Temperature Detector1 ScopeThis guideline gives the evaluation process and evaluation method of performance evaluation of point-type smoke/thermal-fire detector. This instructional technical document is applicable to point-type smoke detectors, point-type temperature detectors, point-type smoke temperature composite fire detectors, It provides guidelines for the performance evaluation of point-type smoke/thermal-fire detectors. This guidance document is also applicable to the performance evaluation of point-type smoke, point-type temperature sensing and point-type smoke temperature composite fire detection algorithm.2 Normative referencesThe following documents contain provisions which, through reference in this Guidance Document, become the provisions of this Guidance Note document. All dated Reference documents, all subsequent amendments (not including errata content), or revisions do not apply to this guidance document, however, drums Recipients of the agreement based on this guidance document are encouraged to study whether the latest versions of these documents are applicable. All undated references The latest version of this document applies to this guidance document. GB 4208-2008 enclosure protection (IP code) (IEC 60529.2001, IDT) GB 4715-2005 Point type smoke detectors GB 4716-2005 point-type temperature and fire detectors GB/T 4718-2006 fire alarm equipment terminology3 Terms and definitionsGB/T 4718-2006 established and the following terms and definitions apply to the guidance of technical documents. 3.1 Subjectiveassessmentmethod Evaluators for the evaluation of fire detectors and technical documents, based on actual work experience, in accordance with certain evaluation procedures, all or Part of the evaluation index to make subjective judgments and give the corresponding assessment of the conclusions of the method. 3.2 Objective assessment method The appraiser evaluates the specific evaluation index of the fire detector to be evaluated through specific tests, simulation tests or simulation calculations Methods. 3.3 Slow development fire slowlydevelopedfire A fire that develops slowly at a rate of smoke rise greater than A/4 per hour (A is the initial response threshold for detector non-compensation).4 requirements4.1 General 4.1.1 The point-type smoke/thermal-fire detectors involved in the evaluation shall first meet the requirements of this Chapter and then evaluate them in accordance with the provisions of Chapter 5. 4.1.2 In addition to the evaluation activities carried out in the product development process, the point-type smoke/thermal-fire detector shall be passed before the performance evaluation National Product Quality Supervision and Inspection. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GBZ24979-2010_English be delivered?Answer: Upon your order, we will start to translate GBZ24979-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GBZ24979-2010_English with my colleagues?Answer: Yes. The purchased PDF of GBZ24979-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |