Basic data
| Standard ID | GB/T 8927-2008 (GB/T8927-2008) |
| Description (Translated English) | Petroleum and liquid petroleum products -- Temperature measurement -- Manual methods |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | E30 |
| Classification of International Standard | 75.180.30 |
| Word Count Estimation | 35,391 |
| Date of Issue | 2008-02-13 |
| Date of Implementation | 2008-09-01 |
| Older Standard (superseded by this standard) | GB/T 8927-1988 |
| Adopted Standard | ISO 4268-2000, MOD |
| Regulation (derived from) | National Standard Approval Announcement 2008 No.2 (Total No.115) |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard specifies the manual measurement of petroleum and petroleum products in the tank temperature method, procedures and equipment. This standard specifies the preferred portable electronic thermometer to measure the temperature given in 4. 1, but can also use other methods. These methods include using a fixed single-point thermometer to measure the temperature and by using a sampling method cup box thermometer, overflowing boxes thermometer and by GB/T 4756 after a thermometer to measure the temperature of the sample into the vial, but the re-sampling method should be preferred overflowing box thermometer to measure the temperature. This standard includes only the manual method of measuring temperature. The average does not include the thermometer automatic metering systems constitute a part of. Oil tank measuring atmospheric temperature thermometer with fixed content automatically see the average GB/T 21451. 4, measuring tanker cabin and oil temperature with pressure tank contents, see the corresponding part of ISO 4266. |
GB/T 8927-2008: Petroleum and liquid petroleum products -- Temperature measurement -- Manual methods
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Petroleum and liquid petroleum products. Temperature measurment. Manual methods
ICS 75.180.30
E30
National Standards of People's Republic of China
Replacing GB/T 8927-1988
Petroleum and liquid petroleum products - Temperature measurements - Manual methods
(ISO 4268.2000, MOD)
Posted 2008-02-13
2008-09-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
Introduction Ⅴ
1 Scope 1
2 Normative references 1
Measures 3 1
3.1 Overview 1
3.2 Measurement Measure 2
3.3 Safety measures 3
4 Equipment 4
4.1 The portable electronic thermometer (PET) 4
4.2 Liquid glass thermometer 7
4.3 Tank sampling temperature measuring device 9
4.4 vapor lock sampler and supporting thermometer 11
4.5 Fixed single point thermometer 12
4.6 with bimetal dial thermometer drive 14
5 reading and reporting 14
6 Methods of measurement 14
6.1 Pressure tank liquid 14
6.2 airtight vapor liquid tank 16
6.3 atmospheric tank liquid near ambient temperature of 17
6.4 atmospheric bare tank more than 15 ℃ temperature difference between the liquid and the environment 20
7 Fixed tanks thermometer calibration method 21
7.1 Overview 21
Specification 7.2 standard thermometer 21
7.3 vertical cylindrical tank calibration step 21
7.4 Inspection vertical cross-sectional area of \u200b\u200bthe tank 21 is inconsistent
8 Use a fixed single-point thermometer 22
8.1 Overview 22
8.2 Fixed single point thermometer position 22
8.3 Thermometer Specifications 22
Representative test measurement data 22 8.4
8.5 using a fixed single-point thermometer of 22
Appendix A (informative) This standard reg number and ISO 4268.2000 reg control number 23
Ambient temperature is measured in Appendix B (informative) 28
A stationary rod tube thermometer protection sleeve 2
Figure 2 A typical cup for thermometer 10
Figure 3 A typical cartridge filled thermometer 11
4 special sampler by using vapor lock example 12
Figure 5 typical corner bar thermometer 13
Table 1 thermometer recommended temperature range 7
Table 2 temperature measurement at different positions and oil deep under the minimum number of 15
Table 3 cups cartridge thermometer is recommended immersion time 18
Foreword
This revised standard adopts ISO 4268.2000 "Petroleum and liquid petroleum products - Temperature Measurement --- Hand Law" (in English), as well as reference
According to the use of the "American Petroleum Measurement Standards Chapter 7 --- Temperature Measurement" technology content.
This standard is based on ISO 4268.2000 re-drafted. The standard lists the reg number in Appendix A and ISO 4268.2000 reg
Control list numbered.
Taking into account China's national conditions, in the use of ISO 4268.2000, the standard of this made some technical amendments. This standard and ISO 4268.
The main difference is 2000.
--- In the scope of application, supplemented with "In the sampling method should be used in preference box filled thermometer to measure the temperature" of the content;
--- As a reference document, ISO 4266 has been divided into six parts, this standard also made corresponding changes. Which Part 4
GB/T 21451.4 instead of the other five parts have not yet developed national standards still refer to international standards;
--- Refers to the standard ISO 386. 1977, ISO 3170. 1988 and ISO 4512 respectively GB/T 514, GB/T 4756 and
GB/T 13894 in place, while increasing the GB/T 19779 as a reference standard;
--- Increase in special security measures regarding benzene terms "For other hazardous liquid petrochemical products, should also adopt the same
Measures. ";
--- For glass thermometer accuracy and resolution, this standard specifically directly in the text, "the resolution of not less than glass thermometer
0.2 ℃ ";
--- Thermometer should clearly state calibration cycle calibrated to suit the actual situation in China;
--- The "indication when the temperature stabilized at 0.1% up to 30s, then the equilibrium has been established." International Standard 7.5.4d) was changed to "When the indication
Temperature changes stabilize within 0.1 ℃ reached the 30s, the equilibrium has been established. ";
--- International standards 7.5.6h) in "Before calculating the average, should receive additional temperature measurement data in the intermediate liquid deep position."
The words "Otherwise, in the middle of two points adjacent liquid deep position and then turn and supplementary temperature, and then calculate the average temperature.";
--- Reference to American Petroleum Measurement Standards Manual, the exposed glass thermometer liquid column were amended grounds supplement;
--- Increase "reading and reporting" as in Chapter 5 of this standard, the international standard of the clauses relating to the thermometer readings and average temperature
Report as of this chapter;
--- Table 3 "15 ℃ Density" is replaced by "20 ℃ Density", where at the same time remove the clause "wooden box back Cup thermometer" and "wood back"
Word;
--- Reference to American Petroleum Measurement Standards Manual, rail tankers for temperature measurement under normal temperature and pressure, how to choose the part of the increased tanker
Temperature measurements of the content;
--- For oil tankers under normal temperature and pressure measurements, referring to American Petroleum Measurement Standards Manual, increased cabin temperature base oil or resid
method;
--- Reference to American Petroleum Measurement Standards Manual, added "Appendix B ambient temperature measurement."
This standard replaces GB/T 8927-1988 "Petroleum and liquid petroleum products - Temperature measurement."
The main changes in the standard of GB/T 8927-1988 compared to the performance in the following areas.
--- Reference standards by the API2543 "Petroleum and liquid petroleum products - Temperature measurement" to ISO 4268 "Petroleum and liquid petroleum products
Temperature Measurement --- Hand Law ";
--- Technologies including thermometer, technical specifications, test equipment, measurement methods, measurement conditions and other more detailed and specific;
--- Portable electronic thermometer thermometer to measure the oil temperature as the first;
--- Fixed thermometer to measure the average temperature of the oil pipeline and manual temperature measurement is no longer used in the present standard content;
--- Supplementary tests using a portable electronic thermometer thermometer stationary technical content;
--- Adjust the temperature inside the tank location and choose the way of the oil;
--- Improve the resolution and accuracy of the thermometer, improving the calculation method of the average temperature, calculated results are accurate to 0.1 ℃.
Appendix A of this standard and Appendix B is an informative annex.
This standard by the National Standardization Technical Committee on Petroleum Products and Lubricants made.
The standard by the China Research Institute of Petroleum Corp. petrochemicals.
This standard is drafted by. China Research Institute of Petroleum Corp. petrochemicals.
Participated in the drafting of this Standard. China Petroleum & Chemical Corporation branch Anqing, China Petroleum and Chemical Corporation Beijing Yan
Hill Branch Refinery, China National Petroleum Corporation pipeline transport of oil and gas Qin Beijing Branch, China National Petroleum Corp.
Lanzhou Petrochemical Company.
The main drafters of this standard. Thin red, Wei Jinxiang, Zhangan Jun, Hu Zhi - min, Chen, Wu Liying.
This standard was first published in 1988.
Introduction
In all calculations involving the number of oil and petroleum products, regardless of volume at standard temperature representation, or use or air quality
The apparent quality representation, we need to determine the average temperature of the oil. This standard method of measuring tanks in oil temperature measurements have help
Under conditions known to the average temperature of the most reliable and relevant tank also includes a road tanker, rail tank and oil cabin.
Temperature measurement errors constitute the greater part of oil and liquid petroleum products - Measurement of the total number of errors, which are nothing but emphasize that no matter how
Points, so the choice and use of the temperature measuring device should be particularly careful. If you want the final measurement results with the smallest error, then
We should be careful to do according to standards.
In the application of this standard, the measured temperature response measurement staff to conduct a comprehensive training, coaching them to report any deviations can not be avoided.
Petroleum and liquid petroleum products - Temperature measurements - Manual methods
1 Scope
This standard specifies the manual measurement of petroleum and petroleum products in the tank temperature methods, procedures and equipment.
This standard specifies the preferred portable electronic thermometer to measure the temperature given in 4.1, but can also use other methods. These ones
The method comprises fixed single-point and a thermometer to measure the temperature by using a sampling cup for thermometer, a thermometer and a box full of press
GB/T 4756 after sampling into a thermometer to measure the temperature inside the vial, but the sampling method should be used in preference box filled thermometer
temperature.
This standard includes only the manual method of measuring the temperature does not include automatic metering system constitute a part of the average thermometer. Fixed self
Moving average thermometer to measure atmospheric temperature of the oil tank contents see GB/T 21451.4, and the measurement of tankers with cabin pressure tank oil temperature
Content see ISO 42661) of the section.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 514 Petroleum products test glass liquid thermometer technical conditions
GB/T 4756 petroleum liquids hand sampling method (GB/T 4756-1998, ISO 3170. 1988, MOD)
GB/T 13894 Petroleum and liquid petroleum products - Measurement of liquid level (manual method)
GB/T 19779 Petroleum and liquid petroleum products - Calculation of oil static measurement
GB/T 21451.4 Petroleum and liquid petroleum product storage tank level and temperature automatic measurement - Part 4. temperature and atmospheric tanks
Measurement (GB/T 21451.4-2008, ISO 4266-4.2002, MOD)
ISO 4266-1 Petroleum and liquid petroleum product storage tanks --- automatic level and temperature measurement method --- Part 1. pressure tank
Level Measurement
ISO 4266-2 Petroleum and liquid petroleum product storage tanks --- automatic level and temperature measurement method --- Part 2. tanker compartment
Level Measurement
ISO 4266-3 Petroleum and liquid petroleum product storage tanks --- automatic level and temperature measurement method --- Part 3. Pressure tank
Level Measurement
ISO 4266-5 Petroleum and liquid petroleum product storage tanks --- automatic level and temperature measurement method --- Part 5. tanker compartment
Temperature Measurement
ISO 4266-6 Petroleum and liquid petroleum product storage tanks --- automatic level and temperature measurement method --- Part 6. Pressure tank
Temperature Measurement
3 measures
3.1 Overview
This chapter gives a general measure within the measuring vessel oil reservoir temperature should be taken. To emphasize the focus on measures and safety measures will be measured
Shi separate statements, both to ensure the reliability of temperature measurement, but also to ensure the safety of depot personnel and metering. With specified equipment must be taken
Special measures to be defined in terms of the equipment related to the.
1) other parts of ISO 4266 is about to be converted to national standards, after the transformation can be directly referenced.
...