Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 8452-2008 English PDF

US$149.00 · In stock
Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 8452-2008: Test method for verticality of glass bottles
Status: Valid

GB/T 8452: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 8452-2008149 Add to Cart 2 days Test method for verticality of glass bottles Valid
GB/T 8452-1987199 Add to Cart 2 days Glass containers--Vertical axis deviation of bottles test methods Obsolete

Similar standards

GB/T 40913   GB 4544   QB/T 3729   GB/T 6552   GB/T 9987   

Basic data

Standard ID: GB/T 8452-2008 (GB/T8452-2008)
Description (Translated English): Test method for verticality of glass bottles
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: Y22
Classification of International Standard: 55.100
Word Count Estimation: 5,551
Date of Issue: 2008-12-30
Date of Implementation: 2009-09-01
Older Standard (superseded by this standard): GB/T 8452-1987
Quoted Standard: GB/T 9987
Adopted Standard: ISO 9008-1991, MOD
Regulation (derived from): National Standard Approval Announcement 2008 No.26 (Total No.139)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies test methods Bolipingguan vertical axis deviation. This standard applies to the measurement of glass containers in vertical axis deviation.

GB/T 8452-2008: Test method for verticality of glass bottles

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test method for verticality of glass bottles ICS 55.100 Y22 National Standards of People's Republic of China Replacing GB/T 8452-1987 Bolipingguan vertical axis deviation test methods (ISO 9008.1991, Glassbottles-Verticality-Testmethod, MOD) Posted 2008-12-30 2009-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This revised standard adopts ISO 9008.1991 "Bolipingguan vertical axis deviation test method" (in English). This standard is based on ISO 9008.1991 re-drafted. This standard and ISO 9008.1991 for the difference. --- Remove the ISO 9008.1991 standard preamble and references; --- Increase the directory with the preface; --- Increasing the normative references and terms and definitions; --- Increased reading microscope measurement tool on the vertical columns; --- Modify the instrument in a self-centering clamping device is described. This standard replaces GB/T 8452-1987 "glass container glass bottles vertical axis deviation test methods." This standard and GB/T 8452-1987 difference is. --- Remove the GB/T 8452-1987 Definitions of terms; --- Increasing the preface of this standard; --- Increasing the normative references and terms and definitions; --- Revised instrument measuring tool in the vertical column description. The standard proposed by China National Light Industry Council. This standard by the National Standardization Technical Committee household glass (SAC/TC377) centralized. This standard was drafted. Donghua University, the National Optical glass enamels Quality Supervision and Inspection Center. The main drafters of this standard. Dai Qi, Zhang . This standard replaces the standards previously issued as follows. --- GB/T 8452-1987. Bolipingguan vertical axis deviation test methods

1 Scope

This standard specifies the test methods Bolipingguan vertical axis deviation. This standard applies to vertical axis deviation measuring glass containers.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 9987 Bolipingguan manufacturing term

3 Terms and Definitions

Terms and definitions GB/T 9987 established in this standard applies.

4 Requirements

4.1 Instrument requirement is to ensure that the bottom of the glass containers can be measured horizontally finish with vertical axis deviation. 4.2 Instrument of measure depends on the type of use. a) by measurements with foot level; b) or dial indicator reading microscope; c) an enlarged projection scale. 4.3 Instrument with the self-centering clamping device and swivel base with a vertical column or horizontal ruler or dial indicator readings microscope Composition, or be accompanied by a V-shaped bottom and a block with a horizontal or vertical ruler or dial indicator reading microscope column composition. Dial indicator, reading Number microscope or horizontal ruler should be able to adjust the height and horizontal position. You can also use non-contact optical scanning device. 4.4 Deviation tools should be placed on the outside edge of the bottle. 4.5 non-circular glass containers should be able to make use of instruments to measure the rotation of the holder in the center of the floor. Note. You can also use other types achieve precision instruments.

5 Sample

Should a predetermined quantity of glass containers tested. Samples should meet the requirements, severe deformation of the bottom glass containers should be removed. Step 6 6.1 Bolipingguan held horizontal rotation on the chassis, swivel base 360 \u200b\u200b°. Such as when used with the V-shaped bottom block, then the sample is close to the V On-block, 45 ° in the horizontal direction exerts a downward pressure on the sample measurement, the rotation Bolipingguan 360 °. Under the outer edge of the bottle and 6.2 recorded maximum and minimum distance between the fixed points, vertical axis deviation is the difference between the measured maximum and minimum values \u200b\u200bof half. 6.3 Measurement accuracy is 0.1mm. 6.4 amended by precision obtained from the measured vertical axis deviation.

7 Test report

The test report shall include the following.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 8452-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 8452-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 8452-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 8452-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 8452-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 8452-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.