GB/T 4698.15-2011 English PDFUS$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 4698.15-2011: Methods for chemical analysis of titanium sponge, titanium and titanium alloys -- Determination of hydrogen content Status: Valid GB/T 4698.15: Historical versions
Basic dataStandard ID: GB/T 4698.15-2011 (GB/T4698.15-2011)Description (Translated English): Methods for chemical analysis of titanium sponge, titanium and titanium alloys -- Determination of hydrogen content Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: H64 Classification of International Standard: 77.120.50 Word Count Estimation: 7,752 Date of Issue: 2011-05-12 Date of Implementation: 2012-02-01 Older Standard (superseded by this standard): GB/T 4698.15-1996 Regulation (derived from): Announcement of Newly Approved National Standards No. 6 of 2011 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the inert gas fusion Thermal conductivity/infrared detection method for the determination of titanium sponge, titanium and titanium in hydrogen content. This section applies to sponge titanium, titanium and titanium alloys Determination of hydrogen content. Measuring range: 0. 0006% -0. 0260 % GB/T 4698.15-2011: Methods for chemical analysis of titanium sponge, titanium and titanium alloys -- Determination of hydrogen content---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of titanium sponge, titanium and titanium alloys. Determination of hydrogen content ICS 77.120.50 H64 National Standards of People's Republic of China Replacing GB/T 4698.15-1996 Sponge titanium, titanium and titanium alloys Determination of the amount of hydrogen Methodsforchemicalanalysisoftitaniumsponge, titaniumandtitaniumaloys- Issued on. 2011-05-12 2012-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis Part replaces GB/T 4698.15-1996 "Sponge titanium, titanium and titanium alloy vacuum heating chemical analysis by gas chromatography The amount of hydrogen. " This portion of the GB/T 4698.15-1996 compared to the main changes are as follows. --- By gas chromatography to thermal conductivity/infrared detection; --- Measured by the scope of 0.0010 percent to 0.030 percent to 0.0006% - 0.0260%; --- Increasing the precision of the terms, complements the quality assurance and control provisions; The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is drafted. Baoji Titanium Group Ltd., Hunan Golden days cast titanium Co., Northwest Nonferrous Metal Research Institute, Sichuan Heng To produce Titanium Technology Co., Zunyi Titanium Co., Ltd. The main drafters of this section. Li Jian, HUANG Yong, Lin Ying, Yang Weiwei, Li Bo, Liang Qinghua, ZHU Guang way to lun strong, Luo Lin. This part of the standard replaces the previous editions are. --- GB/T 4698.15-1984; --- GB/T 4698.15-1996. Sponge titanium, titanium and titanium alloys Determination of the amount of hydrogen1 ScopeThis section provides the inert gas fusion - thermal conductivity/measured Sponge titanium, titanium and titanium alloy hydrogen content in infrared detection. This section applies to sponge titanium, titanium and titanium alloys - Determination of hydrogen content. Measurement range. 0.0006% - 0.0260%.2 principle of the methodA sample was tin flux, placed in a graphite crucible, heated and melted under an inert atmosphere, and hydrogen is released into the molecular carrier gas stream. Molecular hydrogen with other evolved gases (e.g., carbon monoxide, etc.) in TCD separated pools; or hydrogen with the carrier gas molecules by thermal oxidation After the copper is converted to water, in particular the detection of infrared cell. This method is applicable to the use of automated material hydrogen analyzer using standard known hydrogen content Substance/sample calibration.3 Reagents and materials3.1 acetone. 3.2 high soda asbestos. 3.3 argon, nitrogen or helium. purity ≥99.99%. 3.4 tin flux. flake or granular, hydrogen content ≤0.0005%. 3.5 anhydrous magnesium perchlorate. 3.6 sieve. 3.7 Schutz reagent. 3.8 rare earth copper oxide. 3.9 copper wire. 3.10 graphite crucible. pure spectrum. 3.11 Titanium standard material/samples.4 InstrumentThe inert gas fusion - thermal conductivity/infrared detector hydrogen analyzer. (Including one electrode furnace or an induction furnace, purification and analysis of a carrier gas stream conversion system Systems, hydrogen detecting thermal conductivity or infrared detection pool water, computer and software control systems. )5 SampleSample cut or car to 0.10g/blocks ~ 0.30g/block, the process to avoid overheating. If necessary, use a clean rasp setback to the surface dirt Was washed with acetone, air dry.6 Analysis Program6.1 Instrument Preparation According to the instruction to open water, electricity, gas and other external auxiliary facilities, check each device path connecting piece and see how your various reagents consumption Consumption goods state, to ensure the effective reagent. 6.2 Warm up To fully preheated before instrumental analysis, so that the indicators of the instrument reaches the set value. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 4698.15-2011_English be delivered?Answer: Upon your order, we will start to translate GB/T 4698.15-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 4698.15-2011_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 4698.15-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 4698.15-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 4698.15-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |