Path:
Home >
GB/T >
Page663 > GB/T 45305.2-2025
Price & Delivery
US$449.00 · In stock · Download in 9 secondsGB/T 45305.2-2025: Acoustics - Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 45305.2-2025 | English | 449 |
Add to Cart
|
4 days [Need to translate]
|
Acoustics - Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 45305.2-2025 (GB/T45305.2-2025) |
| Description (Translated English) | Acoustics - Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | A59 |
| Classification of International Standard | 91.120.20 |
| Word Count Estimation | 22,219 |
| Date of Issue | 2025-08-01 |
| Date of Implementation | 2026-02-01 |
| Older Standard (superseded by this standard) | GB/T 19889.3-2005 |
| Issuing agency(ies) | State Administration for Market Regulation, Standardization Administration of China |
GB/T 45305.2-2025: Acoustics - Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation
---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT45305.2-2025
ICS 91.120.20
CCSA59
National Standard of the People's Republic of China
Replaces GB/T 19889.3-2005
Laboratory measurement of sound insulation of acoustic building elements
Part 2.Measurement of airborne sound insulation
(ISO 10140-2.2021,MOD)
Released on August 1, 2025
Implementation on February 1, 2026
State Administration for Market Regulation
The National Standardization Administration issued
Table of Contents
Preface III
Introduction V
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Facilities and Equipment 3
5 Test Procedure and Evaluation Calculations 3
5.1 General Principles 3
5.2 Generation of sound field in the sound source room 3
5.3 Data Processing 3
5.4 Result Expression 4
6 Test Arrangement 4
6.1 General Principles 4
6.2 Full-scale test opening 5
6.3 Small size test hole 5
6.4 Small size test piece 5
6.5 Small building components 5
7 Performance Limits 6
7.1 Full-scale test opening 6
7.2 Small size test hole 6
8 Measurement uncertainty 6
9 Test Report 6
Appendix A (Normative) Sound transmission measurement of small-sized or specific small-sized test openings with filling walls and lateral structures 8
A.1 General 8
A.2 Determination of lateral sound transmission 8
A.3 Test result expression 8
Appendix B (Informative) Expression format of measurement results 10
Reference 12
Preface
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents"
Drafting.
This document is Part 2 of GB/T 45305 "Acoustic building elements - Laboratory measurement of sound insulation". GB/T 45305 has been published.
The following sections.
--- Part 2.Measurement of airborne sound insulation;
--- Part 4.Measurement procedures and requirements.
This document replaces GB/T 19889.3-2005 "Acoustic buildings and building elements - Measurement of sound insulation - Part 3.Airborne sound insulation of building elements"
Compared with GB/T 19889.3-2005, in addition to structural adjustments and editorial changes, the main technical changes are as follows.
--- Deleted the "indoor average sound pressure level" in the terms and definitions, and added "structural normalized sound pressure level difference" and "small building components" (see
Chapter 3, Chapter 3 of GB/T 19889.3-2005);
--- Added test content for small building components (see Chapter 1, 3.3, 3.4, 6.5, 7.2 and Appendix A);
--- Deleted "Technical requirements and arrangement of sound sources" and replaced it with a normative reference to ISO 10140-5 (see 5.2, GB/T 19889.3-2005
Appendix C of);
--- Deleted the content on the measurement of average sound pressure level, reverberation time and sound absorption and the correction of background noise, and replaced it with normative reference
GB/T 45305.4 (see 5.3, 6.2, 6.4, and 6.5 of GB/T 19889.3-2005)
--- Deleted the installation details of door, window and glass test pieces and quoted ISO 10140-1 (see 6.1, GB/T 19889.3-2005) instead.
5.2.2);
--- Deleted "Sealants for installing glass in test openings" (see Appendix A of GB/T 19889.3-2005);
--- Deleted "Measurement of lateral sound transmission" and included the revised "Determination method of lateral sound transmission" in Appendix A (see A.2,
Appendix D of GB/T 19889.3-2005);
--- Deleted "Installation Guidelines for Sound Insulation Measurement of Double-layer Lightweight Panel Partition Walls" (see Appendix H of GB/T 19889.3-2005).
This document is modified to adopt ISO 10140-2.2021 "Acoustic building elements - Laboratory measurement of sound insulation - Part 2.Airborne sound insulation"
Measurement".
The technical differences between this document and ISO 10140-2.2021 and their reasons are as follows.
--- The normative reference GB/T 45305.4 replaces ISO 1040-4 (see 5.1, 5.2, 5.3, Chapter 9) to adapt to my country's technical standards.
Technical conditions and increase operability;
--- The normative reference GB/T 19889.2 replaces ISO 12999-1 (see Chapter 8) to adapt to my country's technical conditions.
The following editorial changes have been made to this document.
--- Change the explanatory content in the definition of sound insulation in 3.1 to a note (see Note 1 to 3.1);
--- Change the explanatory content in the definition of apparent sound insulation in 3.2 to a note (see Note 1 to 3.2);
--- Change the explanatory content in the definition of normalized sound pressure level difference of components in 3.3 to a note (see Note 1 of 3.3);
--- Added additional informative information (see note to 5.1);
---Added references.
Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents.
This document was proposed by the Chinese Academy of Sciences.
This document is under the jurisdiction of the National Technical Committee on Acoustics Standardization (SAC/TC17).
This document was drafted by. Tongji University, China Academy of Building Research Co., Ltd., Institute of Acoustics, Chinese Academy of Sciences, Dalian University of Technology
University of Science and Technology, South China University of Technology, Tsinghua University, Nanjing University, Southeast University, Jianke Environmental Energy Technology Co., Ltd., Hangzhou Aihua Intelligent Technology Co., Ltd.
Co., Ltd., Beijing Keok Acoustic Technology Co., Ltd.
The main drafters of this document are. Jiang Guorong, Mo Fangshuo, Tan Hua, Lü Yadong, Zhu Peisheng, Zhao Yuezhe, Yan Xiang, Lin Jie, Tao Jiancheng, Fu Xiuzhang,
Yan Guojun, Xiong Wenbo, Ru Lujing, and Xu Xin.
The previous versions of this document and the documents it replaces are as follows.
---First issued in.2005 as GB/T 19889.3-2005;
---This is the first revision.
introduction
GB/T 45305 "Laboratory measurement of sound insulation of building components" involves laboratory measurement methods for sound insulation of building components, aiming to standardize
Improve the layout of the sound insulation measurement of components in the laboratory to ensure the consistency of the measurement and simplify the installation of test pieces with changes in installation conditions and the need for additional
The supplementary revision work is planned to consist of five parts.
--- Part 1.Application rules for specific products. The purpose is to provide laboratory tests suitable for measuring the sound insulation of specific components and products.
Procedures, including specific requirements for specimen preparation, installation, operation and test conditions.
--- Part 2.Measurement of airborne sound insulation. The purpose is to provide a general measurement procedure for laboratory measurement of airborne sound insulation of building components.
--- Part 3.Measurement of impact sound insulation. The purpose is to provide a general measurement procedure for laboratory measurement of impact sound insulation of floor components.
--- Part 4.Measurement procedures and requirements. The purpose is to provide laboratory measurements of airborne sound insulation and impact sound insulation of building components.
Basic measurement techniques and test procedures.
--- Part 5.Requirements for test facilities and equipment. The purpose is to provide the design, construction and certification of sound insulation measurement laboratory test equipment.
Detailed information required for the installation, additional equipment and measuring instruments.
Laboratory measurements of sound insulation of acoustic building elements
Part 2.Measurement of airborne sound insulation
1 Scope
This document describes a laboratory method for measuring the airborne sound insulation of building elements such as walls, floors, doors,
Windows, shutters, exterior wall components, exterior walls, glass, small building components (such as ventilation devices, vents, outdoor air inlets, electrical cable ducts, pipe ducts, etc.)
insulation and sealing systems) and composite components (e.g. walls and floors with acoustic lining, suspended ceilings or floating floors).
This document is applicable to the measurement of sound insulation of building components. The measurement results are applicable to the comparison and classification of sound insulation performance of building components, which is helpful for the design of
Building products with a certain sound insulation performance and estimation of the on-site sound insulation performance of the building after completion.
The sound insulation measurements in this document are carried out in a laboratory with suppressed lateral sound transmission, without considering lateral sound transmission, boundary conditions and total loss factor.
Under conditions that affect the sound insulation performance, the measurement results are not suitable for directly indicating the on-site sound insulation performance of building components.
2 Normative references
The contents of the following documents constitute the essential clauses of this document through normative references in this document.
For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to
This document.
GB/T 19889.2 Acoustics - Measurement of sound insulation of buildings and building elements - Part 2.Evaluation and application of measurement uncertainty
(GB/T 19889.2-2022,ISO 12999-1.2020,MOD)
GB/T 45305.4-2025 Acoustics - Laboratory measurement of sound insulation of building elements - Part 4.Measurement procedures and requirements
(ISO 10140-4.2021,MOD)
Note. There is no technical difference between the referenced content of GB/T 45305.4-2025 and the referenced content of ISO 10140-4.2021.
ISO 717-1 Acoustics - Ratings of sound insulation of buildings and building elements - Part 1.Airborne sound insulation
ISO 10140-1 Acoustics - Laboratory measurement of sound insulation of building elements - Part 1.Application rules for specific products
cificproducts)
ISO 10140-5 Acoustics — Laboratory measurements of sound insulation of building elements — Part 5.Requirements for test facilities and equipment
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
sound reduction index
The logarithm to the base 10 of the ratio of the sound power incident on the test piece to the transmitted sound power through the test piece, multiplied by 10.
Note 1.The sound insulation R is calculated according to formula (1).
...