Home   Cart   Quotation   Policy   About-Us
www.ChineseStandard.net
SEARCH

GB/T 42658.3-2025 English PDF

US$304.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 42658.3-2025: Surface chemical analysis - Sample handling, preparation and mounting - Part 3: Biomaterials
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 42658.3-2025304 Add to Cart 3 days Surface chemical analysis - Sample handling, preparation and mounting - Part 3: Biomaterials Valid

Similar standards

GB/T 40244   GB/T 35924   GB/T 35930   GB/T 14666   GB/T 42659   GB/T 42658.4   

Basic data

Standard ID: GB/T 42658.3-2025 (GB/T42658.3-2025)
Description (Translated English): Surface chemical analysis - Sample handling, preparation and mounting - Part 3: Biomaterials
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: G04
Classification of International Standard: 71.040.40
Word Count Estimation: 15,176
Date of Issue: 2025-06-30
Date of Implementation: 2026-01-01
Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration

GB/T 42658.3-2025: Surface chemical analysis - Sample handling, preparation and mounting - Part 3: Biomaterials


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT42658.3-2025
ICS 71.040.40 CCSG04 National Standard of the People's Republic of China Surface chemical analysis sample processing, preparation and Installation Part 3.Biological Materials Mounting-Part 3.Biomaterials (ISO 20579-3.2021, IDT) Released on June 30, 2025 Implementation on January 1, 2026 State Administration for Market Regulation The National Standardization Administration issued

Table of Contents

Preface III Introduction IV 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Abbreviations 2 5.Description of the structure of this document 2 6 General requirements and sample classification 3 6.1 General Information 3 6.2 Process 3 6.3 Packaging 3 6.4 Toxic and hazardous materials 3 7 Sample Notes 4 7.1 Sample Origin 4 7.2 Information Search 4 7.3 Sample Classification 4 8 Sample contamination sources 4 8.1 Sample Preparation 4 8.2 Tools 4 8.3 Sample Processing 4 8.4 Separation of adjacent areas 5 9 Sample Storage and Transport 5 9.1 Storage 5 9.2 Temperature and Humidity 5 10.Sample handling procedures to be informed to sample holders 6 11 Sample Installation Procedure 6 12 Methods for reducing sample charge 6 13 Sample Preparation Techniques 6 13.1 Mechanical separation 6 13.2 Slicing Technology 6 13.3 Biomaterial Solvents 6 13.4 Chemical Etching 6 13.5 Ion Sputtering 6 14 Breaking, Cleaving and Scratching 6 15 Sample processing technology 7 References 8 Preface This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document is Part 3 of GB/T 42658.GB/T 42658 has published the following parts. --- Sample treatment, preparation and mounting for surface chemical analysis Part 3.Biological materials. --- Guide for sample handling, preparation and installation for surface chemical analysis Part 4.Reporting of nano-object-related information prior to surface analysis History, preparation, handling and installation information. This document is equivalent to ISO 20579-3.2021 "Sample processing, preparation and mounting for surface chemical analysis Part 3.Biological materials material". Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document is proposed and coordinated by the National Technical Committee for Standardization of Surface Chemistry Analysis (SAC/TC608). This document was drafted by. Xiamen Jiajiyue Network Information Co., Ltd., Tsinghua University, and Institute of Chemistry, Chinese Academy of Sciences. The main drafters of this document are. Yao Wenqing, Li Jianhui, Cen Danxia, Li Zhanping, Zhao Zhijuan, and Wang Shuiju.

introduction

GB/T 42658 is an equivalent to ISO 20579 and is intended to provide analysts and practitioners with comprehensive information on sample handling, storage, and installation. Provide guidance to scientific researchers in surface chemical analysis. GB/T 42658 is intended to consist of four parts. --- Sample handling, preparation and installation for surface chemical analysis Part 1.Recording and reporting sample handling before analysis. This document specifies a method for recording and reporting sample preparation prior to surface chemical analysis that is applicable to all substances, but not to specific Duplicate in the analysis file for the specified substance. --- Sample handling, preparation and installation for surface chemical analysis Part 2.Preparation and installation of samples for recording and reporting analysis. Purpose The purpose of this document is to establish methods for recording and reporting analysis of sample preparation and mounting for surface chemical analysis of all substances, except Methods are not repeated in the analysis file for a specific substance. --- Surface chemical analysis sample processing, preparation and installation Part 3.Biological materials. The purpose is to determine the The method of sample handling, preparation and mounting for surface chemical analysis shall not be repeated in the analysis documentation. --- Guide for sample handling, preparation and installation for surface chemical analysis Part 4.Reporting of nano-object-related information prior to surface analysis The purpose is to define a method for reporting the phase relationship of nano-objects prior to surface chemical analysis that is applicable to all substances. methods of origin, preparation, processing and installation of information. The methods described in this document are mainly for Auger electron spectroscopy (AES), X-ray photoelectron spectroscopy (XPS) and secondary ion mass spectrometry The sample handling, preparation and mounting methods are suitable for surface analytical techniques such as SIMS, but can also be used for many other surface sensitive analytical techniques such as Electron scattering spectroscopy, scanning probe microscopy, low energy electron diffraction and electron energy loss spectroscopy. Sample manipulation may affect the performance of surface sensitive analytical techniques. AES, XPS and SIMS are sensitive to surface layers a few nanometers thick, which may be affected by the sample before it is sent to the analysis chamber. Therefore, proper handling and preparation are crucial for reliable analysis. Can lead to changes in surface composition and unreliable data. This document is specifically designed to assist analysts with sample handling, preparation, and mounting methods for surface chemical analysis of biological materials. The applications of synthetic materials in the human body include metals, ceramics, polymers, glass, carbon and composites. Techniques such as AES, XPS and SIMS are used to analyze inorganic materials, but the methods described can also be used for biological materials. Many other surface-sensitive analytical techniques can be used for sample analysis, such as ion scattering spectroscopy, low-energy electron diffraction, and electron energy loss spectroscopy. Examples of material applications include artificial hip and knee joints, bone plates for fracture fixation, dental implants, optical devices (intraocular lenses), heart valves and cardiovascular The study of vascular systems and membrane materials for guided tissue regeneration. Further examples are discussed [1][2]. Sample processing can affect surface sensitive measurements. Surface chemical analysis methods are usually performed on surface layers that are only a few nanometers thick. It may be seriously affected by improper handling[4][7] or surface treatment necessary before placement in the analysis chamber. Proper sample handling and preparation are crucial. This is particularly critical for the analysis of biological materials, as failure to do so can result in altered surface composition and unreliable data. Proper sample preparation and mounting are particularly critical for surface chemical analysis of biological materials, as failure to do so may result in changes in surface composition and undesirable Reliable analysis. Careful handling of samples to avoid or minimize the introduction of contaminants. Maintain the original surface condition so that the analysis is still on the original specimen surface. This document describes the methods that surface analysts may need to use. method to minimize the impact of sample preparation when using any method. In addition, changes in the surface composition of biomaterials before and after implantation may be a problem related to contamination. The general idea is to specifically address solid surfaces, but also soft surfaces such as self-assembled monolayers (SAMs), hydrogels, scaffolds, and certain polymers. Surface chemical analysis sample processing, preparation and Installation Part 3.Biological Materials 1 Scope This document provides guidance on handling, mounting, and surface preparation methods for biological material samples prior to surface chemical analysis. Helps analysts understand the conditions required to process special samples using the following techniques when performing analysis. ---X-ray photoelectron spectroscopy (XPS) or electron spectroscopy for chemical analysis (ESCA); ---Secondary ion mass spectrometry (SIMS); ---Auger Electron Spectroscopy (AES). The proposed method is also applicable to other techniques that are sensitive to surface composition analysis, such as. ---Attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR); ---Total reflection X-ray fluorescence spectroscopy (TXRF); ---Ultraviolet photoelectron spectroscopy (UPS). This document describes the effects of the vacuum conditions used and the contamination issues before and after testing and before and after implantation, as well as the contamination issues during testing. Biomaterials here include hard and soft materials such as metals, ceramics, scaffolds and polymers. This document does not cover living biological material such as cells, tissues and organisms. Other related topics not covered in this document include Sample preparation for electron or light microscopy. 2 Normative references The contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. ISO 18115-1 Surface chemical analysis — Vocabulary — Part 1.General terms and spectroscopic terms Note. GB/T 22461.1-2023 Surface chemical analysis vocabulary Part 1.General terms and spectroscopic terms (ISO 18115-1.2013, IDT) ISO 18115-2 Surface chemical analysis — Vocabulary — Part 2.Scanning probe microscopy — Terminology Note. GB/T 22461.2-2023 Surface chemical analysis vocabulary Part 2.Scanning probe microscopy terminology (ISO 18115-2.2021, IDT) 3 Terms and Definitions For the purposes of this document, the terms and definitions defined in ISO 18115-1 and ISO 18115-2 and the following apply. 3.1 biomaterial Materials that interface with biological systems to evaluate, treat, enhance or replace any tissue, organ or function of the body. 3.2 biological material Organic and/or inorganic matter produced by living organisms (such as bones, skin, shells, wood and cultured cells).
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 42658.3-2025_English be delivered?

Answer: Upon your order, we will start to translate GB/T 42658.3-2025_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 42658.3-2025_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 42658.3-2025_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.