Mechanical structures for electrical and electronic equipment - Thermal management for cabinets in accordance with inch and metric system - Part 6: Air recirculation and bypass of indoor cabinets
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 40815.6-2026 (GB/T40815.6-2026) |
| Description (Translated English) | Mechanical structures for electrical and electronic equipment - Thermal management for cabinets in accordance with inch and metric system - Part 6: Air recirculation and bypass of indoor cabinets |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | K05 |
| Classification of International Standard | 31.240 |
| Word Count Estimation | 26,218 |
| Date of Issue | 2026-02-27 |
| Date of Implementation | 2026-09-01 |
| Issuing agency(ies) | State Administration for Market Regulation, Standardization Administration of China |
GB/T 40815.6-2026: Mechanical structures for electrical and electronic equipment - Thermal management for cabinets in accordance with inch and metric system - Part 6: Air recirculation and bypass of indoor cabinets
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 31.240
CCSK05
National Standards of the People's Republic of China
Mechanical structure of electrical and electronic equipment
Thermal management compliant with imperial and metric series cabinets
Part 6.Air Recirculation and Bypass in Indoor Cabinets
Released on February 27, 2026; to be implemented on September 1, 2026.
State Administration for Market Regulation
The State Administration for Standardization issued a statement.
Table of contents
Preface III
Introduction IV
1.Scope 1
2 Normative References 1
3.Terms and Definitions 2
4.Recycling Level 2
5.Determination of recirculation rate and bypass rate 3
5.1 Cooling airflow in the cabinet 3
5.2 Recycling rate of the interlocking box 4
5.3 Rack Recycling Rate 4
5.4 Cabinet Bypass Rate 5
6.Measurement of recirculation and bypass 5
6.1 Measurement of the recirculation of the test chamber 5
6.2 Rack Recirculation Measurement 5
6.3 Rack Bypass Measurement 5
6.4 Temperature Measurement Methods 6
6.4.1 Inlet air temperature of the casing 6
6.4.2 Inlet air temperature of the junction box assembly 6
6.4.3 Exhaust air temperature of the casing 6
6.4.4 Exhaust air temperature of the injection unit 6
6.4.5 Rack intake air temperature 7
6.4.6 Rack exhaust temperature 7
6.5 Measurement method for empty rack recirculation 7
Appendix A (Normative) Recirculation Measurement Method Using Simulated Heat Load 8
A.1 Purpose 8
A.2 Technical Requirements 8
A.2.1 DTL 8
A.2.2 Rack Technical Requirements 8
A.2.3 Measurement Configuration 9
A.3 Environmental Conditions 9
A.4 Measurement Point 9
A.4.1 DTL Inlet Air Temperature 9
A.4.2 DTL exhaust temperature 9
A.4.3 Cabinet Inlet Air Temperature 9
A.4.4 Rack exhaust temperature 9
A.4.5 Evaluation of the interlocking box recycle rate 9
A.4.6 Evaluation of rack recirculation rate and bypass rate 9
A.5 Case Study 9
A.6 Relationship between recirculation rate and inlet air temperature rise 13
Appendix B (Normative) Derivation of Recirculation and Bypass in Cabinets 15
B.1 General Provisions 15
B.2 Derivation of Recirculation and Bypass 15
Appendix C (Informative) Application of Recirculation and Bypass in Outdoor Cabinets 16
C.1 General Provisions 16
C.2 Application Example 16
Reference 18
Figure 1.Airflow in the server rack 3
Figure 2.Airflow diagram of the server rack.
Figure A.1 DTL outline diagram 10
Figure A.2 Test setup for cabinet and DTL 10
Figure A.3 DTL Inlet Air Temperature Measurement Point 11
Figure A.4 DTL exhaust temperature measurement point 11
Figure A.5 Rack air inlet temperature measurement point 12
Figure A.6 Cabinet exhaust temperature measurement point 12
Figure A.7 Recirculation rate vs. inlet air temperature rise of 14
Figure C.1 Schematic diagram of airflow in outdoor cabinet 16
Figure C.2 Airflow diagram and air temperature in outdoor cabinet 17
Table 1 Recycling Level 3
Table A.1 DTL Technical Requirements 8
Table A.2 DTL Technical Requirements 10
Table A.3 Experimental Results 13
Table A.4 Cabinet Recycling Rate and Bypass Rate 13
Table C.1 Case Study of Outdoor Cabinets 17
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1.Structure and Drafting Rules of Standardization Documents".
Drafting.
This document is part of GB/T 40815 "Mechanical Structures of Electrical and Electronic Equipment - Thermal Management of Cabinets in Accord and Metric Series".
GB/T 40815 has been published in 6 parts.
---Part 2.Methods for Determining Forced Air Cooling;
---Part 4.Cooling performance test of water supply heat exchanger in electronic cabinet;
---Part 5.Evaluation of Cooling Performance of Indoor Cabinets;
---Part 6.Air recirculation and bypass for indoor cabinets.
This document is equivalent to IEC 62610-6.2020 "Mechanical construction of electrical and electronic equipment conforming to IEC 60297 and IEC 60917 series".
Thermal Management of Server Racks Part 6.Air Recirculation and Bypass for Indoor Server Racks.
The following minimal editorial changes have been made to this document.
---To harmonize with existing standards, the standard name has been changed to "Mechanical Structures of Electrical and Electronic Equipment in Conformity to Imperial and Metric Series".
Thermal Management of Cabinets Part 6.Air Recirculation and Bypass for Indoor Cabinets.
Please note that some content in this document may involve patents. The issuing organization of this document assumes no responsibility for identifying patents.
This document was proposed and is under the jurisdiction of the National Technical Committee on Comprehensive Standardization of Electrical and Electronic Equipment Structures (SAC/TC34).
This document was drafted by. China Guodian Nanjing Automation Co., Ltd., Beijing Electrotechnical Technology and Economic Research Institute of Machinery Industry, and Xiamen Yesheng Electric Co., Ltd.
Gas Co., Ltd., Fiberhome Telecommunication Technologies Co., Ltd., Moju Electric Co., Ltd., Beijing Sifang Relay Protection Engineering Technology Co., Ltd., Nanjing South
Ruijie Electric Co., Ltd., Beijing Sifang Relay Protection & Automation Co., Ltd., and the 36th Research Institute of China Electronics Technology Group Corporation
ZTE Corporation, XJ Electric Co., Ltd., Henan XJ Electric Equipment Co., Ltd., Nanyang Electric Group Co., Ltd.
Hubei Jinfu Technology Co., Ltd., Yunda Energy Technology Group Co., Ltd., China Quality Certification Center Co., Ltd., China Electronics Technology Group Corporation
The 14th Research Institute of the Group Company and Bull Group Co., Ltd.
The main drafters of this document are. Yu Chunlin, Li Jianxia, Guo Yan, Ye Qinci, Mu Linsen, Cui Yu, Xiong Jiawei, Han Zaolin, Yu Haibo, and Jin Dayuan.
Ye Chenlei, Gu Mingfei, Duan Kaiwen, Peng Xuekun, Wang Tinghua, Li Shuainan, Chen Yongli, Xu Feilei, Huang Qiansong, Wang Jiangtao, Tang Yuebin, Peng Xiaohui
Wang Gang, Zhang Liangjuan, Chen Zhenyu, and Ma Chaoqun.
Introduction
Imperial and metric series server racks are widely used in data center computer rooms and various communication equipment rooms for installing various information and communication equipment.
Communication equipment. To improve the heat dissipation efficiency of equipment within the cabinet, ensure safe and efficient operation of the equipment, and reduce energy consumption in the computer room, GB/T 40815 "Electrical Equipment" is required.
The document "Thermal Management of Air and Electronic Equipment Mechanical Structures in Imperial and Metric Series Cabinets" elaborates on the requirements for imperial and metric series cabinets.
This paper presents thermal management methods that provide design guidelines for rack thermal management. The main problems it addresses include.
---Specifies the universal installation interface specifications and requirements for the thermoelectric cooling system of indoor electronic cabinets;
---Specifies the design specifications and requirements for optimal airflow in indoor electronic cabinets and their internal enclosures and chassis;
---Specifications for evaluating the cooling performance of indoor electronic cabinets and thermoelectric cooling systems;
---Specifies the performance test specifications and requirements for water supply heat exchangers in indoor electronic cabinets;
---Specifies the test specifications for air recirculation and bypass of indoor electronic cabinets.
GB/T 40815 is proposed to consist of six parts.
---Part 1.Design Guidelines. Interface Dimensions and Specifications for Thermoelectric Cooling Systems (Peltier Effect). This aims to standardize thermoelectric cooling systems.
It has universal installation interface dimensions and requirements.
---Part 2.Methodology for Determining Forced Air Cooling. This section aims to specify the optimal airflow configuration and design for indoor electronic cabinets, enclosures, and chassis.
method.
---Part 3.Design Guidelines. Evaluation Methods for Thermoelectric Cooling Systems (Peltier Effect). Aimed at standardizing the performance of thermoelectric cooling systems.
Evaluation methods and design guidelines are provided.
---Part 4.Cooling Performance Testing of Water Supply Heat Exchangers in Electronic Cabinets. This section aims to specify the performance testing procedures for water supply heat exchangers.
Fan, guiding the experiment.
---Part 5.Evaluation of Cooling Performance of Indoor Cabinets. This section aims to define a methodology for evaluating the air cooling capacity of indoor electronic cabinets.
---Part 6.Air Recirculation and Bypass in Indoor Cabinets. This section aims to specify the testing methods for air recirculation and bypass in indoor electronic cabinets.
specification.
Parts 1 and 3 correspond to international documents that are technical specifications and have not yet been converted into Chinese documents.
This document proposes a method for easily measuring the airflow recirculation rate and bypass rate within a server rack, clarifying the characteristics of cooling airflow in such racks.
The level of effective recyclability is intended to provide a reference for cabinet equipment integrators and developers.
Mechanical structure of electrical and electronic equipment
Thermal management compliant with imperial and metric series cabinets
Part 6.Air Recirculation and Bypass in Indoor Cabinets
1 Scope
This document pertains to thermal management of cabinets compliant with IEC 60297 and IEC 60917 series standards, providing compatibility measurements for recirculation rate and bypass rate.
These measurement methods define the quality of airflow in forced air cooling and are generally applicable to rack-mounted and/or chassis-based equipment.
Indoor server racks.
Note 1.Both recirculation and bypass represent leaky airflow, which is a detrimental phenomenon in terms of cooling efficiency; their measurement is obviously intended to mitigate this situation.
This document contains the following.
a) Definitions of recirculation and bypass flow rates in cabinet cooling;
b) The level of recirculation rate (RC);
c) The definition formula for the recycle rate RCs of forced air-cooled enclosures and/or enclosure-based equipment installed in the rack;
d) The definition formulas for the recirculation rate RCr and bypass rate BPR of the entire cabinet;
e) Requirements for each temperature measurement method needed to calculate the recirculation rates RCs, RCr, and bypass rate BPR.
Note 2.This document includes provisions for measuring bypass ratio, but does not include provisions for bypass ratio level.
The diagrams used are not intended to guide product design; they are only used for illustrative purposes when defining forced airflow.
The recirculation and bypass measurement methods described in this document assume applicability to indoor-installed cabinets. The cooling air inlet is located at the front of the cabinet.
The heated air is exhausted to the rear or top surface, either on the front or bottom. These methods are also suitable for outdoor installations with heat exchangers at the front or back.
Cabinets for cooling devices such as air conditioners or cooling units (see Appendix C).
The recycle rate of a cabinet or rack is defined for each individual cabinet or rack-based device installed in the rack, or for the entire rack.
The bypass rate of a cabinet is defined for the entire cabinet.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.
For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies.
This document.
IEC 60297-3-100 Mechanical structures of electronic equipment, 482.6 mm (19 in) series, part 3-100.dimensions of mechanical structures.
panels,subracks,chassis,racksandcabinets]
Note. GB/T 19520.16-2015 Mechanical Structures of Electronic Equipment 482.6mm (19in) Series Mechanical Structure Dimensions Part 3-100.Panels, Inserts,
Basic dimensions of chassis, racks and cabinets (IEC 60297-3-100.2008, IDT)
IEC 60917-1 Modular sequence of mechanical structures for developing electrical and electronic equipment - Part 1.General specifications
Part 1.Generic standard)
Note. GB/T 19290.1-2003 Mechanical Structure Modular Sequence for Developing Electronic Devices - Part 1.General Specification (IEC 60917-1.1998,
IDT)
...