GB/T 39673.3-2020 English PDFUS$299.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 39673.3-2020: Home and building electronic systems (HBES) and building automation and control systems (BACS) - Part 3: Electrical safety requirements Status: Valid
Basic dataStandard ID: GB/T 39673.3-2020 (GB/T39673.3-2020)Description (Translated English): Home and building electronic systems (HBES) and building automation and control systems (BACS) - Part 3: Electrical safety requirements Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: K60 Classification of International Standard: 29.120.01 Word Count Estimation: 16,122 Date of Issue: 2020-12-14 Date of Implementation: 2021-07-01 Quoted Standard: GB/T 156-2017; GB/T 16895(���в���); GB/T 16895.6; GB/T 16935.1; GB/T 17045; GB/T 17627; GB/T 39673.1-2020; IEC 60990; IEC 62151-2000; IEC 62949; EN 41003 Adopted Standard: IEC 63044-3-2017, MOD Regulation (derived from): National Standard Announcement No. 28 of 2020 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration Summary: This standard specifies electrical safety requirements for residential and building electronic systems (HBES) and building automation and control systems (BACS). This standard applies to the electrical safety requirements related to HBES/BACS networks in addition to the product safety standards for HBES/BACS equipment. This standard is also applicable to equipment without specific HBES/BACS product safety standards in the HBES/BACS network. In addition, this standard defines the interface of the equipment intended to be connected to an HBES/BACS network. This standard does not apply to interfaces connected to other networks. In addition, this standard also specifies the safety requirements for the interfaces of equipment expected to be connected to the HBES/BACS network. This standard does not apply to interfaces of other networks. Headquarters GB/T 39673.3-2020: Home and building electronic systems (HBES) and building automation and control systems (BACS) - Part 3: Electrical safety requirements---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. (Home and Building Electronic System (HBES) and Building Automation and Control System (BACS) Part 3: Electrical Safety Requirements) ICS 29:120:01 K60 National Standards of People's Republic of China Home and Building Electronic System (HBES) and Building Automation and Control System (BACS) Part 3: Electrical safety requirements (IEC 63044-3:2017, MOD) 2020-12-14 release 2021-07-01 implementation State Administration for Market Regulation Issued by the National Standardization Management Committee Table of contentsPreface Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions, abbreviations 2 4 HBES/BACS network interface classification 4 5 Safety requirements and compliance conditions 5 6 Requirements 5 Appendix A (Informative Appendix) List of Electrical Safety Product Standards 10 Reference 12 Table 1 Requirements for devices connected to a dedicated HBES/BACS network 6 Table A:1 List of electrical safety product standards 10ForewordGB/T 39673 "Home and Building Electronic System (HBES) and Building Automation and Control System (BACS)" intends to publish the following parts: ---Part 1: General requirements; ---Part 2: Environmental conditions; ---Part 3: Electrical safety requirements; ---Part 4: Functional safety; ---Part 5: EMC requirements; ---Part 51: EMC requirements, conditions and test arrangements; ---Part 52: EMC requirements for HBES and BACS used in residential, commercial and light industrial environments; ---Part 53: EMC requirements for HBES and BACS used in industrial environments; ---Part 6: Planning and installation of HBES: This part is Part 3 of GB/T 39673: This section was drafted in accordance with the rules given in GB/T 1:1-2009: This part uses the redrafting law to amend and adopt IEC 63044-3:2017 "Housing and Building Electronic System (HBES) and Building Automation And Control System (BACS) Part 3: Electrical Safety Requirements: The technical differences between this part and IEC 63044-3:2017 and the reasons are as follows: ---Regarding normative reference documents, this section has made adjustments with technical differences to adapt to my country's technical conditions and adjustments: The situation is collectively reflected in Chapter 2 "Normative Reference Documents", and the specific adjustments are as follows: ● Replace IEC 60038:2009 with GB/T 156-2017 modified to adopt international standards; ● Replace IEC 60364 (all parts) with GB/T 16895 (all parts) equivalent to adopting international standards; ● Replace IEC 60364-5-52 with GB/T 16895:6 equivalent to the international standard; ● Replace IEC 60664-1 with GB/T 16935:1 equivalent to the international standard; ● Replace IEC 61180 (all parts) with GB/T 17627 (all parts) equivalent to international standards; ● Replace IEC 63044-1 with GB/T 39673:1 modified to adopt international standards: This section has made the following editorial changes: ---According to the relevant regulations of GB/T 1:1-2009, in Chapter 1 "Scope", "This part of GB/T 39673 provides Electrical safety requirements for home and building electronic systems (HBES) and building automation and control systems (BACS)"; ---Added in Appendix A the product standards for residual current operated protective devices (RCD) and arc fault protective devices (AFDD) List: This part was proposed by China Electrical Equipment Industry Association: This part is under the jurisdiction of the National Electrical Accessories Standardization Technical Committee (SAC/TC67): Drafting organizations of this section: Weikai Testing Technology Co:, Ltd:, Jiangsu Tongling Technology Co:, Ltd:, Feidiao Electric Group Co:, Ltd:, Hangzhou Hong Yan Electric Co:, Ltd:, Guangdong Midea HVAC Equipment Co:, Ltd:, Bull Group Co:, Ltd:, Simon Electric (China) Co:, Ltd:, Zhejiang Youmoo Technology Co:, Ltd:, Guangdong Xinruan Technology Co:, Ltd:, China National Electrical Equipment Research Institute Co:, Ltd:, Zhuhai Gree Electric Co:, Ltd:, Dongguan Ruijing Electrical Technology Co:, Ltd:, Xiamen Keli Electronics Co:, Ltd:, Xiamen Meike Security Technology Co:, Ltd:, Xiamen Kexin Electronics Co:, Ltd:, Xiamen Wanming Electronics Co:, Ltd:, Shaanxi Yatney Electronics Co:, Ltd:, Xiamen Kunjin Electronic Technology Co:, Ltd:, Zhejiang De Lixi International Electrical Co:, Ltd:, Huizhou Xidun Industrial Development Co:, Ltd:, Jiangxi Gumei New Testing Technology Co:, Ltd: The main drafters of this section: Sun Ting, Chen Bin, Xu Yizhong, Fei Bin, Yan Jie, Liu Bingren, Qiao Cheng, Yang Lingling, Ni Qingqing, Cai Jun, Fan Lingyun, Lin Jinli, Yi Zhonghui, Wu Yuansheng, Li Junxu, Huang Jingming, Quan Yongde, Huang Shufu, He Anmin, Li Liang, Chen Yonglong, Zhao Xiaohua, Lin Zhi, Xiao Ying:IntroductionGB/T 39673 involves the development and testing of home and building electronic systems (HBES) and building automation and control systems (BACS): This section involves the electrical safety requirements of HBES/BACS: This part is based on the idea that equipment that is considered electrical safety according to appropriate product safety standards, when connected to the network It also needs to be safe: In addition to the specified product standards, this part also specifies the HBES/BACS equipment connected to the network The electrical safety requirements necessary to maintain safety under normal and single fault conditions of the HBES/BACS network, and at the same time under normal and single fault conditions One or more HBES/BACS devices connected to the HBES/BACS network under certain conditions: This includes preventing overcharge on the network To prevent the danger caused by connecting different types of circuits, limit the influence of contact current on the network, and prevent the communication line from overheating: HBES/BACS network is any interconnection between HBES/BACS products: HBES/BACS network can be The ICT network with interfaces divided by IEC 62949 can also be a dedicated network divided by grid power, ELV, FELV, SELV or PELV circuits The internet: For HBES/BACS products connected to ICT networks, the requirements in IEC 62949 apply: For HBES/BACS products connected to a dedicated HBES/BACS network, the circuit between the device and the network is specified The electrical isolation requirements between (see Table 1): These regulations on electrical isolation follow the basic safety publication GB/T 16935:1 and The principles given in GB/T 17045 meet the installation requirements of GB/T 16895: The following compromises were used: ---According to the principle of GB/T 16935:1, the rated pulse voltage used for isolation should be the pulse voltage on the network and connected to the network The higher value of the rated pulse voltage of the equipment circuit; ---The overvoltage category considered by GB/T 16935:1 refers to the overvoltage directly drawn from the power supply; ---Overvoltage from other sources (such as capacitive coupling) is not specified in GB/T 16935:1: GB/T 16935:1 Recommendation The technical committee shall specify the overvoltage category or rated impulse voltage as appropriate: For the purpose of this section, the following pulse voltages have been specified: ---For the network (FELV, SELV or PELV circuit) electrically isolated from the main, the pulse overvoltage from the isolated network side is fixed The installation network limit is 2:5kV: The limit on the detachable network is 1:5kV; ---For ICT networks, there are special requirements (see 6:3:2:1): Home and Building Electronic System (HBES) and Building Automation and Control System (BACS) Part 3: Electrical safety requirements1 ScopeThis part of GB/T 39673 specifies the electrical power of residential and building electronic systems (HBES) and building automation and control systems (BACS): Gas safety requirements: This section applies to electrical safety related to HBES/BACS networks, in addition to product safety standards for HBES/BACS equipment Claim: This section also applies to equipment that does not have a specific HBES/BACS product safety standard in the HBES/BACS network: In addition, this section defines the device interface expected to be connected to an HBES/BACS network: This section does not apply to connecting to other The interface of the network: In addition, this section also determines the security requirements for the device interface expected to be connected to the HBES/BACS network: This section does not apply to His network interface: Note: An example of other networks is the dedicated ICT network covered by IEC 62949: This section applies to: ---Operation station and other man-machine interface equipment; ---Management function equipment; ---Control equipment, automation stations and application-specific controllers; ---Field equipment and its interface; --- Wiring and interconnection of equipment: The above is used in a dedicated HBES/BACS network: This section covers the following requirements and compliance criteria: ---Protect equipment from harm; ---Prevent network overvoltage; ---Contact current protection; ---Prevent the harm caused by different types of circuits; ---Protect communication lines from overheating due to excessive current:2 Normative referencesThe following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article Pieces: For undated references, the latest version (including all amendments) applies to this document: GB/T 156-2017 standard voltage (IEC 60038:2009, MOD) GB/T 16895 (all parts) low-voltage electrical installations [IEC 60364 (all parts)] GB/T 16895:6 Low-voltage electrical installations Part 5-52: Selection and installation of electrical equipment wiring system (GB/T 16895:6- 2014, IEC 60364-5-52:2009, IDT) GB/T 16935:1 Insulation coordination of equipment in low-voltage systems Part 1: Principles, requirements and tests (GB/T 16935:1- 2008, IEC 60664-1:2007, IDT) ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 39673.3-2020_English be delivered?Answer: Upon your order, we will start to translate GB/T 39673.3-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 39673.3-2020_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 39673.3-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |