| GB/T 39087-2020 English PDFUS$409.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 39087-2020: Health informatics - Health informatics profiling framework Status: Valid 
 Basic dataStandard ID: GB/T 39087-2020 (GB/T39087-2020)Description (Translated English): Health informatics - Health informatics profiling framework Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: L67 Classification of International Standard: 35.240.80 Word Count Estimation: 22,276 Date of Issue: 2020-09-29 Date of Implementation: 2021-04-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 39087-2020: Health informatics - Health informatics profiling framework---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Health informatics - Health informatics profiling framework ICS 35.240.80 L67 National Standards of People's Republic of China Feature description framework of health informatics (ISO /T R17119.2005,MOD) 2020-09-29 released Implementation on 2021-04-01 State Administration for Market Regulation Issued by the National Standardization Management Committee Table of contentsPreface Ⅲ Introduction Ⅳ 1 Scope 1 2 Terms and definitions 1 3 HIPF general rules 2 4 HIPF method 3 5 Reference and comparison between HIPF and other frameworks 7 Appendix A (informative appendix) HIPF background description 8 Appendix B (informative appendix) HIPF example meta-model 10 Appendix C (informative appendix) HIPF unit example 13 Appendix D (informative appendix) Comparison of HIPF with other frameworks and models 15 Reference 16ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard uses the redrafting method to modify and adopt ISO /T R17119.2005 "Health Informatics Health Informatics Characterization Framework". Compared with ISO /T R17119.2005, this standard has made the following structural adjustments. --- Deleted Appendix E of ISO /T R17119.2005. The technical differences between this standard and ISO /T R17119.2005 and the reasons are as follows. ---The scope of this standard was modified in accordance with the rules of GB/T 1.1-2009, and 1.1 in ISO /T R17119.2005 was deleted And 1.4, adjust 1.2 and 1.3 in ISO /T R17119.2005 to Appendix A; ---Deleted 7 terms in ISO /T R17119.2005.2.2compatibility, 2.3concept, 2.5data, 2.7gran- ularity, 2.13information, 2.14interface, 2.16top-down, to adapt to my country's technical conditions; --- Deleted paragraph 4 and subsequent paragraphs in 3.1 of ISO /T R17119.2005 to adapt to my country's technical conditions; ---Adjust paragraphs 2 and 3 in 3.2 of ISO /T R17119.2005 to note (see 3.2) to adapt to my country's technical conditions; --- Deleted paragraphs 1 to 4 in 3.3 of ISO /T R17119.2005 to adapt to my country's technical conditions; --- Modify multiple suspended paragraphs in Chapter 4 of ISO /T R17119.2005 into clauses, and delete ISO /T R17119.2005 The second and third paragraphs of 4.1 in order to adapt to my country's technical conditions; --- Deleted the first and third paragraphs in Chapter 5 of ISO /T R17119.2005 to adapt to the technical conditions of our country. This standard also made the following editorial changes. ---Deleted the explanatory paragraph about the international standard formulation process in Appendix A of ISO /T R17119.2005; ---Corrected the format error of Table D.1 in ISO /T R17119.2005; ---Unify the "physical layer" and "physical design layer" into the "physical design layer" in the full text. This standard was proposed and managed by the China National Institute of Standardization. Drafting organizations of this standard. China National Institute of Standardization, Shanghai University of Traditional Chinese Medicine, Hefei Yunlian Hongda Information Technology Co., Ltd., Anhui Sen Ai Chi Hospital Management Co., Ltd., Beijing University of Technology, Shanghai Hygiene and Health Development Research Center (Shanghai Medical Science and Technology Information Research Institute), Shenzhen Tongbiao Technology Co., Ltd., Shenzhen Municipal Health Commission, Bozhou Xunfei Information Technology Co., Ltd., Zhuhai Dingjibiao Quasi-Technology Co., Ltd., Jianhe Kyushu (Beijing) Technology Co., Ltd., Shanghai Archives of Traditional Chinese Medicine, Shanghai Pudong New Area Guangming Traditional Chinese Medicine Hospital, Shanxi Toushi Xindejia Biotechnology Co., Ltd., Chaozhou Hede Biotechnology Co., Ltd., Shandong Shengquan Pension Service Group Co., Ltd., Zhejiang Hao Luowei Medical Technology Co., Ltd., Chengdu Gaoxin Bingzhengtang Chinese Medicine Clinic Co., Ltd. The main drafters of this standard. Ren Guanhua, Li Jing, Jiang Zhimou, Fang Liye, Ren Zhihua, Fu Rao, Li Jinxuan, Wu Peikai, Qiao Baoliang, Li Dan, Liu Shengnan, Jia Yang, Qi Jialong, Xu Li, Tang Xiudan, Zuo Denghua, Qiu Yanmo, Ying Zhibiao, Miao Feng, Liang Bo.IntroductionThe Health Informatics Profiling Framework (HIPF) aims to describe health information in an orderly manner. Information science standard artifacts. As a general description method, HIPF can promote the coordination of interdisciplinary and cross-jurisdictional health informatics standards. Harmony, communication and comparability. HIPF is based on other important information frameworks. This standard is not used to limit or promote the consistency between informatics standards and its formulation work, but to describe existing and ongoing The established health informatics standards provide a useful description tool. Feature description framework of health informatics1 ScopeThis standard specifies the concept, method and application of the health informatics characterization framework, and gives a reference and comparison with other frameworks. This standard applies to the development and application of health informatics standards.2 Terms and definitionsThe following terms and definitions apply to this document. 2.1 Artifact Models, documents or work products. 2.2 Context Conditions and situations used to understand the meaning and meaning of a subject. 2.3 Framework A structure used to support or encapsulate other things, usually used to divide complex things into multiple simple components. 2.4 Health informatics characterization framework healthinformaticsprofilingframework HIPF A method and tool for describing various artifacts in the field of health informatics standards. 2.5 HIPF unit HIPFcel A unit defined in the context of the HIPF classification matrix and formed by the intersection of the HIPF perspective and the HIPF specificity. 2.6 HIPF classification matrix HIPF classification matrix Including the dimensions of health informatics standard artifacts---a structure of specificity levels and perspectives. 2.7 HIPF perspective HIPF perspective A classification dimension that distinguishes health informatics standard artifacts according to their viewpoints, expected goals, or concerns. Note. This classification dimension includes 6 perspectives. content, method, location, participant, time and reason, see 4.2.2.3 for details. 2.8 HIPF specificity A classification dimension that distinguishes health informatics standard artifacts according to their level of abstraction in implementing regulations. Note. This classification dimension includes 3 specific layers, namely conceptual layer, logical layer and physical design layer, see 4.2.2.2 for details. 2.9 Feature profile Brief description, outline or summary. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 39087-2020_English be delivered?Answer: Upon your order, we will start to translate GB/T 39087-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 39087-2020_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 39087-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |