GB/T 36571-2018 English PDFUS$439.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 36571-2018: Technical specification for measurement and verification of electric energy and power savings for parallel reactive power compensation project Status: Valid
Basic dataStandard ID: GB/T 36571-2018 (GB/T36571-2018)Description (Translated English): Technical specification for measurement and verification of electric energy and power savings for parallel reactive power compensation project Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: F20 Classification of International Standard: 29.240.01 Word Count Estimation: 22,252 Date of Issue: 2018-09-17 Date of Implementation: 2019-04-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 36571-2018: Technical specification for measurement and verification of electric energy and power savings for parallel reactive power compensation project---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Technical specification for measurement and verification of electric energy and power savings for parallel reactive power compensation project ICS 29.240.01 F20 National Standards of People's Republic of China Parallel reactive power compensation saves power Measurement and verification specifications Published on.2018-09-17 Implementation of.2019-04-01 State market supervision and administration China National Standardization Administration issued ContentForeword III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Main contents of measurement and verification 2 5 Technical requirements for measurement and verification 2 6 Uncertainty analysis and assessment 7 Appendix A (Normative Appendix) Calculation of Parallel Reactive Power Savings 9 Appendix B (informative appendix) Calculation of reactive economy equivalent value 12 Appendix C (informative) Example of measurement uncertainty assessment 14ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents. This standard is proposed and managed by the China Electricity Council. This standard was drafted. China Electric Power Research Institute, State Grid Hunan Electric Power Company, State Grid Hunan Energy Saving Service Co., Ltd., State Grid Gan Subsidiary Power Company Electric Power Research Institute, China Southern Power Grid Integrated Energy Co., Ltd., State Grid Shandong Energy Conservation Service Co., Ltd., State Grid Henan Festival Energy Service Co., Ltd., Beijing Xuji Electric Co., Ltd., State Grid Electric Power Research Institute, State Grid Energy Conservation Service Co., Ltd. (Beijing), State Grid Western Electric Power Company, State Grid Xinjiang Electric Power Company Electric Power Research Institute, National Power Investment Group Shandong Energy Development Co., Ltd. The main drafters of this standard. Jiang Limin, Meng Hao, Zhong Ming, Guo Bingqing, Xu Xianyong, Luo Zhikun, Zhang Jianhua, Peng Longsheng, Ling Meng, Shen Rui Bao, Wang Zhiliang, Liu Hao, Tian Xueliang, Lv Zhilai, Zhang Lianghua, Chen Zheng, Zhou Qi, Wang Yong, Li Zaizhong. Parallel reactive power compensation saves power Measurement and verification specifications1 ScopeThis standard stipulates that a parallel reactive power compensation device is installed in the power supply and distribution system, and the reactive power of the connected system is made when it is in normal and stable operation. Power consumption and power saving and power measurement and verification methods, including the main content of measurement and verification, test plan, technical requirements, no Deterministic analysis and assessment. This standard is applicable to the certification of energy saving and the evaluation of energy saving effects after the parallel reactive power compensation device is put into operation in the power distribution system. It is suitable for the planning, design, construction and transformation of parallel reactive power compensation devices in power supply and distribution systems.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 16664-1996 Energy-saving monitoring method for enterprise power supply and distribution system GB/T 20298-2006 Static reactive power compensation device (SVC) functional characteristics GB/T 28750-2012 General rules for energy measurement and verification GB/T 32823-2016 Technical Guidelines for Energy Savings Measurement and Verification of Power Grid Energy Saving Projects DL/T 448-2016 Technical Regulations for Energy Metering Devices DL/T 5242-2010 35kV~220kV substation reactive power compensation device design technical regulations JJF1059.1-2012 Measurement uncertainty evaluation and representation EVO10100-1..2014 International Energy Efficiency Measurement and Verification Protocol Statistics and Uncertainty (Internationalper- formancemeasurementandverificationprotocol-StatisticsanduncertaintyforIPMVP)3 Terms and definitionsThe terms and definitions defined in GB/T 28750-2012, GB/T 32823-2016 and DL/T 5242-2010 apply to This document. For ease of use, some of the terms and definitions in DL/T 5242-2010 are repeated below. 3.1 Reactive power compensation device reactivecompensationequipment A general term for devices that compensate for capacitive or inductive reactive power. [DL/T 5242-2010, definition 3.0.21] 3.2 Parallel reactive compensation paralelreactivepowercompensation The reactive power compensation device is installed in parallel in the substation, power line, distribution transformer and terminal power equipment to improve the access system. Power factor, reduced power loss and improved power quality. 3.3 Reactive economy equivalent reactivepowereconomicequivalent The decrease in the active power loss of the system caused by the reduction of unit reactive power in the power distribution system. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 36571-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 36571-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 36571-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 36571-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |