US$369.00 · In stock · Download in 9 secondsGB/T 28737-2012: Controller for solar water heating system (tank volume more than 0.6 m3)
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 28737-2012 | English | 369 |
Add to Cart
|
3 days [Need to translate]
|
Controller for solar water heating system (tank volume more than 0.6 m3)
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 28737-2012 (GB/T28737-2012) |
| Description (Translated English) | Controller for solar water heating system (tank volume more than 0.6 m3) |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | F12 |
| Classification of International Standard | 27.160 |
| Word Count Estimation | 16,159 |
| Quoted Standard | GB/T 191; GB/T 2829; GB/T 3797; GB 4208; GB 4706.1; GB/T 5023.3; GB/T 5023.5; GB 7251.1; GB/T 7251.8; GB/T 10217; GB/T 11463; GB/T 12936; GB/T 13384; GB 14048.1; GB 14536.1; GB/T 17212; GB/T 23888; GB 50364; JB/T 8734.2 |
| Regulation (derived from) | National Standards Bulletin No. 28 of 2012 |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard specifies the solar water heating system (tank volume greater than 0. 6m3) control unit (hereinafter referred to as controls) the terms and definitions, product classifications and nomenclature, technical requirements, test methods, inspecti |
GB/T 28737-2012: Controller for solar water heating system (tank volume more than 0.6 m3)
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS27.160
F12
National Standards of People's Republic of China
Solar hot water system (tank volume greater than 0.6m3)
The control device
Controlerforsolarwaterheatingsystem (tankvolumemorethan0.6m3)
Issued on. 2013-06-01 2012-11-05 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Product Classification and Nomenclature 2
5 Technical requirements 3
6 Test methods 7
7 Inspection rules 9
8 Marking 10
9 packaging, transportation and storage 10
Appendix A (informative) copper wires to carry the current table 11
Appendix B (normative) in short-term thermal stress caused by the current case, the calculation method to protect conductor cross-sectional area of \u200b\u200b12
Table 1, taxonomic composition and content 2
Table 2 Temperature sensor technical requirements and installation position table 4
Table 3 different color phase sequence or polar line 5
Table 4 different phase sequence or the polarities of 6
Table 5 protective conductor cross-section 6
Foreword
This standard rule according to GB/T 1.1-2009 given draft.
This standard by the National Standardization Technical Committee of solar energy (SAC/TC402) and focal points.
This standard was drafted. Beijing Bo Creative Energy Technology Co., National Solar Quality Supervision and Inspection Center (Beijing), China Standard
Research Institute of Zhejiang Unlimited New Energy Co., Zhejiang Electronic Technology Co., Ltd than the gorgeous, over Zhejiang New Energy Co., days
Electronics Co., Ltd., Himin Solar Co., Ltd., Zhejiang peak Technology Co., Ltd. Tongji sunshine new energy.
The main drafters of this standard. Jia Tieying, Zhang Yiyu, He Tao, Tang Xuan, Zhang Lifeng, Gao Ying, Xu Guohong, pay deposit that, Fang, Zhu Guohua,
Wu Liren, Yangkuai Qiang, Zhang Xin Yu, Fengai Rong, Deng Yu, Zhu even yellow, Zhang Lei, Wang Conghui.
Solar hot water system (tank volume greater than 0.6m3)
The control device
1 Scope
This standard specifies a solar hot water system (tank volume greater than 0.6m3) The term means (hereinafter referred to as the control device) and control
Definition, classification and naming of products, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage.
This standard applies to tank volume greater than 0.6m3 solar hot water systems.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated edition applies to this article
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 191 Packing Pictorial marking
GB/T 2829 periodic inspection Sampling procedures and tables (suitable for process stability test)
GB/T 3797 electrical control equipment
GB 4208 enclosure protection (IP code)
Safety - Part 1 GB 4706.1 household and similar electrical appliances. General requirements
GB/T 5023.3 rated voltage of 450/750V and below PVC insulated cables - Part 3. Non - sheathed fixed wiring
cable
GB/T 5023.5 rated voltage of 450/750V and below PVC insulated cables Part 5. Flexible cables (cords)
GB 7251.1 low voltage switchgear and control equipment Part 1. Type - tested and partially type-tested assemblies
GB/T 7251.8 Low-voltage switchgear and control equipment, intelligent equipment common technical requirements
GB/T 10217 Electrical control equipment design guidelines
GB/T 11463 reliability tests for electronic measuring instruments
GB/T 12936 term solar thermal
GB/T 13384 mechanical and electrical products packaging General technical conditions
GB 14048.1 voltage switchgear and control equipment - Part 1. General
GB 14536.1 household and similar electrical controls - Part 1. General requirements
GB/T 17212 industrial process measurement and control - Terms and definitions
GB/T 23888 domestic solar hot water system controller
GB 50364 civil solar water heating system technical specifications
JB/T8734.2 rated voltage of 450/750V and below PVC insulated cables and wires and cords - Part 2. fixed wiring
Cable & Wire
3 Terms and Definitions
GB 4706.1, GB/T 12936, GB 14048.1, GB 14536.1, GB/T 17212, GB/T 23888, GB 50364 defined
The following terms and definitions apply to this document.
3.1
Solar water heating system control device solarwaterheatingsystemcontroler
For solar water heating systems, solar hot water system gives control to adjust it according to the specified logical policy electrical normal operation
...