GB/T 2467-2008 English PDFUS$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 2467-2008: Pyrites and concentrate -- Determination of lead content -- Flame atomic absorption spectrometric and EDTA volumetric methods Status: Valid GB/T 2467: Historical versions
Basic dataStandard ID: GB/T 2467-2008 (GB/T2467-2008)Description (Translated English): Pyrites and concentrate -- Determination of lead content -- Flame atomic absorption spectrometric and EDTA volumetric methods Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: D51 Classification of International Standard: 73.060.01 Word Count Estimation: 7,773 Date of Issue: 2008-05-14 Date of Implementation: 2008-10-01 Older Standard (superseded by this standard): GB/T 2467.1-1996; GB/T 2467.3-1996 Quoted Standard: GB/T 601; GB/T 6003.1; GB/T 6682; GB/T 9723 Regulation (derived from): National Standard Approval Announcement 2008 No.8 (Total No.121) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard specifies the determination by flame atomic absorption spectrometry and EDTA volumetric method Pyrites and concentrate lead content. This standard flame atomic absorption spectrometry applied to the lead content of 0. 01% to 1% of Pyrites and concentrate products. EDTA volumetric method applies Pyrites and concentrate products greater than 0. 1% lead content determination. GB/T 2467-2008: Pyrites and concentrate -- Determination of lead content -- Flame atomic absorption spectrometric and EDTA volumetric methods---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Pyrites and concentrate. Determination of lead content. Flame atomic absorption spectrometric and EDTA volumetric methods ICS 73.060.01 D51 National Standards of People's Republic of China Replacing GB/T 2467.1-1996, GB/T 2467.3-1996 Pyrites and concentrate - Determination of lead content Flame atomic absorption spectrometric and EDTA volumetric method Posted 2008-05-14 2008-10-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard replaces GB/T 2467.1-1996 "Pyrites and concentrate - Determination of lead content - Part 1. Flame atomic absorption spectrometry Law "and GB/T 2467.3-1996" Pyrites and concentrate - Determination of lead content - Part 3. EDTA volumetric method ", these two standard It merged into a quasi-standard, divided into two methods. The standard proposed by China Petroleum and Chemical Industry Association. This standard is under the jurisdiction of Chemical Industry Standardization Technical Committee chemical mine. This standard was drafted. even in the blue sea and Design Institute. The main drafters of this standard. the king of peace, Zhang Xiaomei. This standard replaces the standards previously issued as follows. --- GB/T 2467.1-1996; --- GB 2467-1981, GB/T 2467.3-1996. Pyrites and concentrate - Determination of lead content Flame atomic absorption spectrometric and EDTA volumetric method1 ScopeThis standard specifies the flame atomic absorption spectrometric and EDTA volumetric method Pyrites and concentrate of lead content. This standard flame atomic absorption spectrometry applied to the lead content of 0.01% to 1% Pyrites and concentrate products, EDTA content Method for the determination of Pyrites and concentrate products lead content greater than 0.1%.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. Preparation of GB/T 601 chemical reagent standard titration solution GB/T 6003.1 woven wire mesh test sieve (GB/T 6003.1-1997, eqv ISO 3310-1.1990) GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-1992, neq ISO 3696. 1987) GB/T 9723 Chemicals flame atomic absorption spectrometry General3 SampleThe sample passes through 150μm test sieve (GB/T 6003.1), at 100 ℃ ~ 105 ℃ drying to constant weight, placed in a desiccator, cooled to Room temperature.4 General ProvisionsThe water of this standard shall comply with GB/T 6682 water in three specifications; reagents listed Unless otherwise specified, refer to analytical reagent.5 Analysis5.1 Flame Atomic Absorption Spectrometry 5.1.1 Method summary Samples with hydrochloric acid - nitric acid is dissolved in dilute hydrochloric acid medium, using air - acetylene flame atomic absorption spectrometer at a wavelength of 283.3nm The absorbance was measured to determine the lead content of working curve method. 5.1.2 Reagents and solutions 5.1.2.1 hydrochloric acid. 5.1.2.2 hydrochloric acid solution. 1 + 1. 5.1.2.3 nitrate. 5.1.2.4 Lead standard solution. 1.00mg/mL. Weigh 1.0000g purity metal lead in 250mL beaker, add 40mL of nitric acid Solution (1 + 1), cover the surface of the pan, heat to dissolve completely cooled and transferred to 1000mL volumetric flask, dilute to the mark, shake. This solution Liquid lead (Pb) amount of 1.00mg/mL. 5.1.2.5 Lead standard solution.200μg/mL. Draw 100.0mL lead standard solution (5.1.2.4) in 500mL flask with water Dilute to the mark. This solution is lead (Pb) the amount of 200μg/mL. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 2467-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 2467-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 2467-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 2467-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 2467-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 2467-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |