Path:
Home >
GB/T >
Page659 > GB/T 22232-2008
Price & Delivery
US$214.00 · In stock · Download in 9 secondsGB/T 22232-2008: Test method for the thermal stability of chemicals by differential scanning calorimetry
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See
step-by-step procedureStatus: Valid
| Std ID | Version | USD | Buy | Deliver [PDF] in | Title (Description) |
| GB/T 22232-2008 | English | 214 |
Add to Cart
|
3 days [Need to translate]
|
Test method for the thermal stability of chemicals by differential scanning calorimetry
|
Click to Preview a similar PDF
Basic data
| Standard ID | GB/T 22232-2008 (GB/T22232-2008) |
| Description (Translated English) | Test method for the thermal stability of chemicals by differential scanning calorimetry |
| Sector / Industry | National Standard (Recommended) |
| Classification of Chinese Standard | A80 |
| Classification of International Standard | 13.300 |
| Word Count Estimation | 11,195 |
| Date of Issue | 2008-06-19 |
| Date of Implementation | 2009-02-01 |
| Quoted Standard | GB/T 22233; ASTM E473; ASTM E691; ASTM E967; ASTM E968 |
| Adopted Standard | ASTM E537-2002, IDT |
| Regulation (derived from) | Announcement of Newly Approved National Standards No. 10 of 2008 (total 123) |
| Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
| Summary | This standard applies to a determination of a minimum number of sample material change in enthalpy, estimates enthalpy change in temperature, and by differential scanning calorimetry or pressure differential scanning calorimetry to determine their enthalpy. This test method can be solid, liquid or slurry samples were measured. This test method may be at an absolute pressure range of 100Pa ~ 7MPa, temperature range of 300K ~ 800K inert or reactive gas. This standard uses the International System of Units. This test method is not equivalent to the ISO standard. This standard involving hazardous materials, operations and equipment. This standard does not purport to address all safety issues associated with. Establish appropriate safety and health practices and regulatory limitations prior to use to determine the applicability of this standard is the user's responsibility. Specific preventive measures see chapter VIII. |
GB/T 22232-2008: Test method for the thermal stability of chemicals by differential scanning calorimetry
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test method for the thermal stability of chemicals by differential scanning calorimetry
ICS 13.300
A80
National Standards of People's Republic of China
Determination of the thermal stability of chemical substances
Differential scanning calorimetry
Posted 2008-06-19
2009-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard is equivalent to using ASTME537-2002 "Standard Test Method for Thermal Stability chemicals differential scanning calorimetry Determination"
(In English).
This standard is managed by the National Standardization Technical Committee chemicals dangerous (SAC/TC251) and focal points.
Participated in the drafting of this standard. the Chemical Institute of Standardization, Jiangxi Entry-Exit Inspection and Quarantine of Guangdong.
Drafters of this standard. Liaoyan Yan, Wang Xiaobing, Huang Lili, Mei Jian, Boyan Gang, Zhou Wei, Chen Gufeng, Xi Zhang Jun, Chen Qiang.
This standard is the first release.
ASTM Foreword
ASTME-27 Committee is currently engaged in the development of potentially dangerous chemicals measured approach to this potential is usually estimated by
Use CHETAH7.0 program to calculate the maximum energy of chemicals or mixtures of chemicals derived reaction.
Note. The complete assessment of the potential hazards of chemical substances must be tested methods or CHETAH this project did not consider some practical considerations into account.
The committee adopted the "potential danger" refers to materials under different environmental conditions the degree of sensitivity or ignition energy release.
The primary purpose of this test method is to detect chemicals enthalpy (enthalpy) changes in the estimated ignition temperature and enthalpy (heat). Differential scanning calorimetry
Advantages of using a small amount of sample, a few milligrams of sample can be detected.
Determination of the thermal stability of chemical substances
Differential scanning calorimetry
1 Scope
This standard applies to the determination of a sample with a minimum amount of material change in enthalpy, enthalpy change estimate occurs at a temperature, and by differential scanning
The amount of heat or pressure differential scanning calorimetry method to determine their enthalpy (heat).
This test method can be solid, liquid or slurry samples were measured.
This test method may be inert at an absolute pressure range of 100Pa ~ 7MPa, the temperature range of 300K ~ 800K (27 ℃ ~ 527 ℃) or
Reactive gas is carried out.
This standard uses SI units.
There is no equivalent to the ISO standard this detection method.
This standard relates to other hazardous materials, operations and equipment. This standard does not claim to solve all the associated security issues. The establishment of appropriate
Safety and health practices and determine the applicability of regulatory limitations prior to use of this standard is the user's responsibility. Specific safety precautions
See Chapter 8.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
Standard Terminology Relating to GB/T 22233 potentially dangerous chemicals
ASTME473 terms related to thermal analysis
Room ASTME691 test method to determine the accuracy of laboratory research guide
ASTME967 differential scanning calorimetry and differential thermal analysis Temperature Calibration Guide
ASTME968 differential scanning calorimetry hot stream alignment guide
Test methods ASTME1860 thermal analyzer calibration elapsed time
NOTE. ASTM standard Yearbook, Vol 14.02.
3 Terms and Definitions
ASTME473, GB/T 22233 and established the following terms and definitions apply to this standard.
3.1
Differential recording format (see Figures 1 and 2 and the scanning calorimeter kind of heat flux for the vertical axis, temperature or time abscissa
The ASTME473 term).
3.2
Part of a single process generates heat curve. Common and established baseline deviation, maximum deviation and reconstruction baseline to describe, heavy
Built baseline are not necessarily the same as before and peak (see Figure 1).
Note. The temperature scanning may be the case, as shown in FIG. 2 immediately after an endothermic or exothermic connections. These competing reactions
Type, it is difficult and sometimes impossible to locate the real peak and starting temperature.
...