Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 19212.16-2017 English PDF

US$359.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 19212.16-2017: Safety of transformers, reactors, power supply units and combinations thereof -- Part 16: Particular requirements and tests for isolating transformers for the supply of medical locations
Status: Valid

GB/T 19212.16: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 19212.16-2017359 Add to Cart 4 days Safety of transformers, reactors, power supply units and combinations thereof -- Part 16: Particular requirements and tests for isolating transformers for the supply of medical locations Valid
GB 19212.16-2005519 Add to Cart 3 days [GB/T 19212.16-2005] Safety of power transformers, power supply units and similar devices -- Part 16: Particular requirements for isolating transformers for the supply of medical locations Obsolete

Similar standards

GB/T 19212.5   GB/T 10228   GB/T 8286   GB/T 19212.14   GB/T 19212.24   GB/T 19212.11   

Basic data

Standard ID: GB/T 19212.16-2017 (GB/T19212.16-2017)
Description (Translated English): Safety of transformers, reactors, power supply units and combinations thereof -- Part 16: Particular requirements and tests for isolating transformers for the supply of medical locations
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K41
Classification of International Standard: 29.180
Word Count Estimation: 18,151
Date of Issue: 2017-12-29
Date of Implementation: 2018-07-01
Older Standard (superseded by this standard): GB/T 19212.16-2005
Regulation (derived from): National Standards Bulletin 2017 No. 32
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 19212.16-2017: Safety of transformers, reactors, power supply units and combinations thereof -- Part 16: Particular requirements and tests for isolating transformers for the supply of medical locations



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Safety of transformers, reactors, power supply units and combinations thereof - Part 16. Particular requirements and tests for isolating transformers for the supply of medical locations ICS 29.180 K41 National Standards of People's Republic of China Replacing GB/T 19212.16-2005 Transformers, Reactors, Power Supplies and Their Combinations Part 16. Isolation transformers for the supply of medical premises Special requirements and tests Safetyoftransformers, reactors, powersupplyunitsandcombinationsthereof- Part 16.Particularrequirementsandtestsforisolatingtransformersfor (IEC 61558-2-15.2011, Safety of transformers, reactors, powersupplyunitsand combinationsthereof-Part 2-15.Particularrequirementsandtestsforisolating transformersforthesupplyofmedicallocations, MOD) 2017-12-29 published.2018-07-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 General Requirements 2 5 General description of the test 2 6 rating 2 7 Categories 2 8 logo and other information 3 9 shock protection 3 10 Change of input voltage setting value 3 11 load output voltage and output current 3 12 no-load output voltage 3 Short circuit voltage 4 14 fever 4 Short circuit and overload protection 4 16 Mechanical strength 5 17 Dust, solid foreign objects and protection against damp entry 5 Insulation resistance, dielectric strength and leakage current 5 Structure 19 20 components 8 Internal wiring 8 22 Power connections and other external flexible cables or cords 8 External lead terminal 8 24 protective grounding device 8 25 screws and connections 8 Creepage distances, clearances and distances through insulation 8 27 heat, flame and tracking resistance 8 28 rust 8 Appendix 9 Appendix H Electronic Circuits 10 Appendix L Routine test (production test) 11 Reference 12 Figure 101 Circuit for measuring the ground leakage current to the output winding 6 Figure 102 Circuit Required to Measure Leakage Current through Ground Protective Conductor 6

Foreword

GB/T 19212 "Transformers, Reactors, Power Supplies and Their Combination Safety" 1) consists of the following parts. --- Part 1. General requirements and tests; --- Part 2. Particular requirements and tests for the power supply for general purposes separation transformers and built-in separation transformers; --- Part 3. Particular requirements and tests for controlling the power supply of transformers and control transformers built in; --- Part 4. Gas and oil burners ignition transformers special requirements and tests; --- Part 5. Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers; --- Part 6. Particular requirements and tests for razor transformers, shaver power supply units and razor power supply units; --- Part 7. Particular requirements and tests for power supply units for safety-isolated transformers and built-in safety isolating transformers; --- Part 8. Particular requirements and tests for transformers and power supplies for toys; --- Part 9. Bell and electric bell transformers and power supply special requirements and tests; --- Part 10. Particular requirements and tests for transformers and power supply units for class III portable tungsten lamps; --- Part 13. Constant voltage transformer special requirements; --- Part 14. Particular requirements and tests for autotransformers and power supply units incorporating autotransformers; --- Part 15. Particular requirements and tests for the power supply of voltage regulators and built-in voltage regulators; --- Part 16. Particular requirements and tests for isolation transformers for power supply in medical premises; --- Part 17. Particular requirements and tests for transformers for switching power supply units and switching power supply units; --- Part 20. Interference attenuation transformer special requirements; --- Part 21. Particular requirements and tests for small reactors; --- Part 24. Particular requirements for transformers used in construction sites; --- Part 27. Particular requirements and tests for energy-saving and other purposes for transformers and power supply units. This section GB/T 19212 Part 16. This section is based on the GB/T 19212.1-2016 developed on the basis of this section Need to be used with GB/T 19212.1-2016. This section is GB/T 19212.1-2016 the corresponding chapter, Article supplement and repair Change in order to GB/T 19212.1-2016 content into the contents of this section. This section is for GB/T 19212.1-2016 added The added content starts from 101. This section drafted in accordance with GB/T 1.1-2009 given rules. This Part replaces GB/T 19212.16-2005 "Safety of power transformers, power supply units and similar products Part 16. Medical field Particular requirements for isolation transformers for power supply ". Compared with GB/T 19212.16-2005, the main technical changes are as follows. --- Standard name changed to "transformers, reactors, power supply and its combination of safety Part 16. Medical premises power supply with isolation Transformer special requirements and tests "; --- Modify the scope of the provisions (see Chapter 1); --- Modify the normative references (see Chapter 2); --- Modify the terms "isolation transformer for medical premises power supply" and "functional shielding" is defined, the term "no-load input power Flow "(see Chapter 3); --- Increase the requirements of signs and other information (see Chapter 8); 1) Some of the standards in this series are under the heading "Safety of Power Transformers, Power Supplies, Reactors and Similar Products" and some are under the heading "Supply Voltage Under the heading "Safety of transformers, reactors, power supply units and similar products up to and including 1100V" under the heading "Transformers, Reactors, Power Source device and its combination of security "heading, the title of the series of standards released in the future may be modified. --- Modify the short-circuit voltage and inrush provisions (see Chapter 13); --- Added additional heating test requirements (see 14.101); --- Increase the short circuit and overload protection requirements (see Chapter 15); --- Modify the insulation resistance, dielectric strength and leakage current requirements (see Chapter 18); --- Modify the provisions of the structure (see Chapter 19); --- Removed Appendix C and Appendix D (see.2005 version of Appendix C and Appendix D); --- Added Appendix H, modified Appendix L (see Appendix H and Appendix L). This section uses the redrafted law to amend the use of IEC 61558-2-15.2011 "transformers, reactors, power devices and their combination of security All sections 2-15 - Particular requirements and tests for isolating transformers for the supply of medical premises ". This section there are technical differences compared with IEC 61558-2-15.2011, all of these differences are due to this part of the supporting standards GB/T 19212.1-2016 and IEC 61558-1.2009 in Chapter 2 arising from the technical differences arising. This section also made editorial changes, the IEC 61558-2-15.2011 6.1 ~ 6.4 to 6.101 ~ 6.104. This part is proposed by China Electrical Equipment Industry Association. This part of the national small-scale power transformers, reactors, power devices and similar products Standardization Technical Committee (SAC/TC418) Focused. This part of the drafting unit. Shenyang Transformer Research Institute Co., Ltd., National Broadcasting and Television Product Quality Supervision and Inspection Center, Shanghai Quality Supervision and Inspection Institute of Technology, Ministry of Industry and Information Technology Institute of the Fifth Institute for Quality and Safety Testing Center Bao. The main drafters of this section. Lin Ran, Zhang Yafang, Yu Yimin, Sun Jianlong, Zhang Hong. This part replaces the standards previously issued as. --- GB/T 19212.16-2005. Transformers, Reactors, Power Supplies and Their Combinations Part 16. Isolation transformers for the supply of medical premises Special requirements and tests

1 Scope

This clause GB/T 19212.1-2016 is replaced by the following. This part of GB/T 19212 specifies the safety requirements for isolation transformers for medical premises. Note 1. Safety requirements include electrical, temperature and mechanical aspects. Unless otherwise specified, the following "transformers" include isolation transformers for the supply of medical premises. This section applies to standing, single-phase or three-phase, air-cooled (self-cooled or air-cooled) Group II medical IT systems for medical power supply Independent dry isolation transformer. It is permanently connected to the fixed wire of the IT system on the secondary side. Winding can be encapsulated or not Closed. Note 2. IT power system requirements see GB/T 16895.1. Note 3. The installation procedures for Group II medical IT system medical facilities are contained in GB/T 16895.24. Note 4. This section relates to the transformer used for medical places power supply. All other transformers or equipment connected downstream of the transformer are not included in this section In points. Rated power supply voltage does not exceed AC 1000V, rated power frequency and internal operating frequency does not exceed 500Hz. For single-phase and three-phase transformer rated output of not less than 0.5kVA, and not more than 10kVA. This section also applies to transformers that do not limit the rated output if the purchaser and the manufacturer otherwise agree. Note 5. This section does not include transformers to be supplied to the distribution network. For single-phase or three-phase transformers (phase voltage), no-load output voltage and rated output voltage does not exceed 250VAC. This section does not apply to the power supply device. This section does not apply to the external circuit to be connected with the input and output terminals of the transformer and its components. When installing procedures or electricity This specification requires the use of the transformers included in this section when double insulation or reinforced insulation between circuits is required. Note 6. Note the following. --- Additional requirements (other applicable standards, national codes, etc.) may be required for transformers intended for use on vehicles, ships or aircraft; --- Should consider taking protective measures to avoid the external components such as molds, pests, termites, solar radiation and icing in the shell and shell; --- Should consider the transformer transport, storage and work of different conditions; --- For transformers scheduled to be used in special environments, additional requirements may be used in accordance with other applicable standards and national regulations.

2 Normative references

Except for the following quotations, the chapter GB/T 19212.1-2016 applies. The chapter adds the following references. GB/T 19212.1-2016 Safety of transformers, reactors, power supply units and combinations - Part 1. General requirements and tests (IEC 61558-1.2009, MOD)

3 Terms and definitions

In addition to the following terms and definitions, GB/T 19212.1-2016 of this chapter apply.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 19212.16-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 19212.16-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 19212.16-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 19212.16-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 19212.16-2017?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 19212.16-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.