Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 14864-2013 English PDF

US$879.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 14864-2013: Solid-polyethene insulated flexible radio-frequency cables
Status: Valid

GB/T 14864: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 14864-2013879 Add to Cart 6 days Solid-polyethene insulated flexible radio-frequency cables Valid
GB/T 14864-1993RFQ ASK 6 days Radio frequency cables with solid polyethylene dielectric Obsolete

Basic data

Standard ID: GB/T 14864-2013 (GB/T14864-2013)
Description (Translated English): Solid-polyethene insulated flexible radio-frequency cables
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: L26
Classification of International Standard: 33.120.10
Word Count Estimation: 40,423
Older Standard (superseded by this standard): GB/T 14864-1993
Quoted Standard: GB/T 2951.11-2008; GB/T 3953-2009; GB/T 4909.2-2009; GB/T 8170; GB/T 8815-2008; GB/T 15065-2009; GB/T 17650.2-1998; GB/T 17651.2-1998; GB/T 17737.1-2000; GB/T 17737.1-2013; GB/T 18380.12-2008; JB/T 3135-2011; YD/T 760-1995; IEC 61196-1-103-2005; IEC 61196
Regulation (derived from): National Standards Bulletin No. 25 of 2013
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the RF cable soft solid polyethylene insulation product classification, requirements, test methods, quality assessment and logo, packaging, transportation and storage. This standard applies to radio communications and electronic de

GB/T 14864-2013: Solid-polyethene insulated flexible radio-frequency cables

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Solid-polyethene insulated flexible radio-frequency cables ICS 33.120.10 L26 National Standards of People's Republic of China Replacing GB/T 14864-1993 Soft solid polyethylene insulated RF cable Issued on. 2013-12-17 2014-05-15 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Product Category 2 3.1 Part 2 3.2 Series and Title 2 3.3 Schematic 3 3.4 Product marking 4 3.5 project uses data 4 4 4 technical requirements and test methods 4.1 cable construction and materials 4 4.2 Electrical properties 10 16 4.3 Environmental and mechanical properties Combustion Characteristics 17 4.4 4.5 mark 18 4.6 length 18 18 5 Inspection Rules 5.1 General 18 5.2 Inspection classification 18 5.3 factory inspection 18 20 5.4 Type inspection 6 packaging, labeling, transportation and storage 20 6.1 Packaging 20 6.2 mark 20 Transport and storage 20 6.3 Appendix A (informative) project uses data 22 Appendix B (normative) LSZH polyolefin sheath material 34 key performance indicators Annex C (normative) Off voltage test halo 35 Annex D (informative) Identification of the type test sample extended grouping 36

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GB/T 14864-1993 "Solid PE insulated radio frequency cable." This standard compared with GB/T 14864-1993, the main technical changes are as follows. --- Standard name changed to "soft solid polyethylene insulated RF cable"; --- Increasing the type designation and code meaning description (see 3.1); --- According to the practical application of the product, increasing the polyethylene sheath and LSZH polyolefin sheathed product specifications (see Table 3 ~ table 5); --- Increased combustion performance requirements and test methods for flame retardant cable (see 4.4); --- Eccentricity increased media requirements (see Section 4.1.3); --- The engineering data dimensional stability as the content requirements (see 4.3.6); --- The project uses data adjusted by the content of the standard text to Appendix A; --- "Length measurement error should not exceed ± 10%" to "length measurement error of ± 0.5%" (see 46, 1993. Version 4.4.); --- Increase in Appendix B "halogen flame retardant polyolefin sheath material key performance indicators"; --- Increase in Appendix C "voltage test destroy Halo." Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China. This standard is under the jurisdiction of the National electronic equipment with a high-frequency cables and connectors Standardization Technical Committee (SAC/TC190). This standard was drafted. Tianjin six hundred and nine cable Co., Ltd., China Electronics Technology Group Corporation No. 23 Research Institute. The main drafters of this standard. Zhangguo Ju, Pan Bing, Yang Guang, Wangrui Zhen, Wu Zhengping, Xu Xiaochuan, Shu Qin Gang, Shi Wei arrows. This standard replaces the standards previously issued as follows. --- GB/T 14864-1993. Soft solid polyethylene insulated RF cable

1 Scope

This standard specifies the soft solid polyethylene insulated RF cable product classifications, requirements, test methods, quality assessment and signs, packaging, Transport and storage. This standard applies to radio communications and electronic devices employing similar techniques used in soft solid polyethylene insulated RF cable.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2951.11-2008 cable and the cable Common test methods for insulating sheathing materials - Part 11. Common test methods --- Measurement of thickness and overall dimensions --- mechanical tests (IEC 60811-1.2001, IDT) GB/T 3953-2009 electrician round copper wire GB/T 4909.2-2009 Test methods for bare wires - Part 2. Measure GB/T 4910-2009 tinned round copper wire GB/T 8170 repair value expressed about the rules and limit values \u200b\u200band judgment GB/T 8815-2008 with a soft PVC wire and cable GB/T 15065-2009 black polyethylene plastic wire and cable Gases evolved during combustion of GB/T 17650.2-1998 materials from cables - Test methods - Part 2. Measurement pH and conductivity to determine the gas acidity (idt IEC 60754-2.1991, AmendmentNo.1.1997) GB/T 17651.2-1998 of cables burning under defined conditions Measurement of smoke density - Part 2. Test procedure and requirements (Idt IEC 61034-2.1997) GB/T 17737.1-2000 frequency cables - Part 1. Generic specification - General, definitions, requirements and test methods (idt IEC 61196- 1.1995) GB/T 17737.1-2013 Coaxial communication cables - Part 1. Generic specification - General, definitions and requirements (IEC 61196-1.2005, IDT) GB/T 18380.12-2008 burning test and optical fiber cables under fire conditions - Part 12. single insulated wire and cable fire Test 1kW pre-mixed flame spread vertical flame test methods (IEC 60332-1-2.2004, IDT) JB/T 3135-2011 silver-plated soft round copper wire YD/T 760-1995 Local telecommunication cables with polyolefin insulation materials IEC 61196-1-102.2005 Coaxial communication cables - Part 1-102. Electrical test methods - Insulation resistance test cable media (Coaxialcommunicationcables-Part 1-102. Electricaltestmethods-Testforinsulationresistanceof cabledielectric) IEC 61196-1-103.2005 Coaxial communication cables - Part 1-103. Electrical test methods for electric cables - Capacitance test (Coaxial communicationcables-Part 1-103. Electricaltestmethods-Testforcapacitanceofcable) IEC 61196-1-105.2005 Coaxial communication cables - Part 1-105. Electrical test methods for cable dielectric withstanding voltage test (Coaxialcommunicationcables-Part 1-105. Electricaltestmethods-Testforwithstandvoltageof cabledielectric)
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 14864-2013_English be delivered?

Answer: Upon your order, we will start to translate GB/T 14864-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 14864-2013_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 14864-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 14864-2013?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 14864-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.