GB/T 13163.4-2014 English PDFUS$474.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 13163.4-2014: Radiation protection instrumentation -- Radon and radon decay product measuring instruments -- Part 4: Equipment for the production of reference atmospheres containing radon isotopes and their decay products (STAR) Status: Valid
Basic dataStandard ID: GB/T 13163.4-2014 (GB/T13163.4-2014)Description (Translated English): Radiation protection instrumentation -- Radon and radon decay product measuring instruments -- Part 4: Equipment for the production of reference atmospheres containing radon isotopes and their decay products (STAR) Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: F84 Classification of International Standard: 13.280 Word Count Estimation: 24,239 Date of Issue: 9/3/2014 Date of Implementation: 2/1/2015 Quoted Standard: GB/T 2900.81-2008; GB/T 2900.82-2008; IEC 60050-111-1996; ISO/IEC GUIDE 99-2007; ISO/IEC 17025; ICRP 32; ICRP 38; ICRP 65 Adopted Standard: IEC 61577-4-2009, IDT Regulation (derived from): People's Republic of China Announcement of Newly Approved National Standards No. 21 of 2014 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Standard applies to test radon test system (STAR) radon and radon measuring instruments needed in the reference radon gas. The following terms and conditions established neither solve all methods produce radon reference atmospheres are all issues ass GB/T 13163.4-2014: Radiation protection instrumentation -- Radon and radon decay product measuring instruments -- Part 4: Equipment for the production of reference atmospheres containing radon isotopes and their decay products (STAR)---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Radiation protection instrumentation Radon and radon decay product measuring instruments Part 4. Equipment for the production of reference atmospheres containing radon isotopes and their decay products (STAR) ICS 13.280 F84 National Standards of People's Republic of China Radiation protection instrumentation - Radon and radon measuring instrument Part 4. containing radon isotopes and their daughters Reference atmosphere generating device (radon test system) measuringinstruments-Part 4. Equipmentfortheproductionofreference atmospherescontainingradonisotopesandtheirdecayproducts (STAR) (IEC 61577-4.2009, IDT) Issued on. 2014-09-03 2015-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsPreface Ⅰ Introduction Ⅱ 1 Scope and objectives 1 2 Normative references 1 3 Terms, definitions and units 1 3.1 General terms and definitions 2 3.2 terminology and definitions 3 3.3 Units and conversion factors 5 4 radon test system (STAR) General Description 6 4.1 Overview 6 4.2 STAR operation mode 7 Characteristics 5 STAR 8 5.1 Overview 8 5.2 for radon STAR 8 5.3 STAR 10 for radon and RnDP 6 STAR reference radon claim 11 6.1 Overview 11 6.2 Reference conditions 12 6.3 Effect of the amount of 12 7 STAR used in the measurement methods and instrumentation calibration and traceability 14 7.1 traceability chain 14 7.2 Quality Assurance 15 Gas environmental characteristics Appendix A (informative) can be simulated in the STAR 16 References 18 Figure 1 STAR consists of. general 6 Figure 2 STAR minimum requirement of 7 Figure 3 STAR dynamic operation of 8 Table 1 Reference conditions and standard test conditions 12 Table 2 with the impact of the change in the test 12 Table A.1 atmosphere characteristic range (typ.) 16ForewordGB/T 13163 "Radiation protection instrumentation - Radon and radon measuring instrument" is divided into four parts. --- Part 1. General principles; --- Part 2. Particular requirements for radon measuring instruments; --- Part 3. radon measuring instruments special requirements; --- Part 4. generating device containing radon isotopes and their daughters reference atmosphere (radon test system). This section GB/T Part of 413,163. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses the translation method is equivalent to using IEC 61577-4.2009 "Radiation protection instrumentation - Radon and radon measuring instruments - Part 4. Includes Isotopes of radon and its daughters reference atmosphere generating device (radon test system). " Consistency correspondence with international standards in this part of the country cited the following documents. --- GB/T 2900.61-2008 Electrotechnical terminology physical and chemical (IEC 60050-111.1996, MOD); --- GB/T 18216 (all parts) 1000V AC and 1500V DC low voltage distribution systems Electrical Safety measures Facilities for testing, measuring or monitoring equipment [IEC 61557 (all parts)]; --- GB/T 27025-2008 testing and calibration laboratories General requirements (ISO /IEC 17025.2005, IDT). For ease of use, this section of IEC 61577-4.2009 made the following editorial changes. --- "2 Normative references" to delete the text does not appear in the IEC 61557; --- Table A.1 footnote number with a, b instead of *, **; --- According to the domestic habits, atmospheric pressure units to international standards "hPa" indicates changed to "kPa" expressed. This part of the National Nuclear Instrument Standardization Technical Committee (SAC/TC30) and focal points. This section drafted by. China Institute of Atomic Energy. The main drafters of this section. Xing rain, extraordinary capacity, Yang Jing, Wei Kexin.IntroductionRadon is a radioactive gas, respectively, by the earth's crust natural radionuclides 238U, 235U and 232Th daughter of 226Ra, 223Ra and 224Ra decay produced. Isotopes of radon (222Rn, 219Rn and 220Rn) by three decay chain decay, and finally terminates in the stable lead with Isotope. Note. Under normal circumstances, due to the very short half-life of 219Rn, compared with the two other series of radon activity, its activity and decay daughters (RnDP1)) activity Can be ignored, its health effects are not important. Therefore, in this part of 219Rn and its decay daughters is not considered. Radon decay of short-lived isotopes and their respective daughters (RnDP) (for example. 222Rn of 218Po, 214Pb, 214Bi, 214Po, 220Rn of 216Po, 212Pb, 212Bi, 212Po, 208Tl) is very important, as they form public and occupational radiation exposure of staff to accept the natural home To section. In some workplaces. personnel (such as underground mines, mineral water and waterworks) work by a very significant level of radon Exposure. Radon is a gas and its isotopes and their daughter are fine particles of these different amounts of airborne radionuclides are present in the form. High accuracy Measurement of natural radioactivity in the atmosphere of this level for health physics is valuable. Since these radioactive elements in the air and in phase The measuring instrument should have unique behavioral characteristics, it is necessary to test methods for measuring instruments such norms. For ease of application, GB/T 13163 series of standards are divided into the following different parts. GB/T 13163.1. focus on specialized areas of measuring radon and radon (RnDP) The term with the unit, a brief introduction for radon RnDP test and measurement equipment and calibration of radon test system (STAR). GB/T 13163.2. This section is dedicated to 222Rn and 220Rn meter test. GB/T 13163.3. This section is dedicated to the 222Rn and 220Rn daughters (RnDP222 and RnDP220) meter test. GB/T 13163.4. detailed description of the structure and application of the STAR test. 1) RnDP is the abbreviation of radon decay products, and radon daughters equally be used (see reference [1]). Radiation protection instrumentation - Radon and radon measuring instrument Part 4. containing radon isotopes and their daughters Reference atmosphere generating device (radon test system)1 Scope and objectivesGB/T 13163 contains radon and radon testing and calibration of measuring instruments general characteristics, but also provides the proof instrument qualified to perform Type test. GB/T 13163.2-2005 and GB/T 13163.3-2014 describes these types of tests. This section only relates to measure Instruments and related methods 220Rn and 222Rn and its short-lived daughter isotope amount of gas. This section applies to test radon test system (STAR) radon and radon measuring instruments needed in reference radon gas. The following terms only It does not resolve the establishment produces radon and its daughters reference gas environment with all issues related to the equipment, can not describe all the methods used, but Experiencing these problems can guide people to choose the best method can be employed in all relevant knowledge.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2900.81-2008 Electrotechnical terminology Nuclear Instruments Physical phenomena and basic concepts (IEC 60050-393.2003, IDT) GB/T 2900.82-2008 Electrotechnical terminology nuclear instrumentation equipment, systems, equipment and detectors (IEC 60050-394.2007, IDT) IEC 60050-111.1996 International Electrotechnical Vocabulary Chapter 111. Physics and Chemistry (Internationalelectrotechnicalvo- cabulary (IEV) -Part 111. Physicsandchemistry) ISO /IEC Guide 99.2007 International Metrology Vocabulary of Basic and General Concepts and Associated Terms (VIM) (Internationalvo- cabularyofmetrology-Basicandgeneralconceptsandassociatedterms (VIM)) ISO /IEC 17025 General requirements for testing and calibration laboratories (Generalrequirementsforthecompetenceof testingandcalibrationlaboratories) ICRP32 staff suction limit radon progeny (Limitsforinhalationofradondaughtersbyworkers) ICRP38 Radionuclide transformation. energy and emission intensity (Radionuclidestransformations, energyandinten- sityofemissions) ICRP65 at home and at work protection of 222Rn (Protectionagainstradon-222athomeandatwork) 3 Terms, definitions and units The following terms, definitions and units apply to this document. The entire standard, the term radon and radon isotopes in this section represent all involved. Especially when a certain isotope, its chemical symbol in the upper left Angular acceleration mass number represents (such as 220Rn, 222Rn). Due to historical reasons, 220Rn is also called thoron. The term radon daughters (radondecayproduct, Acronym RnDP) refers to the total short-lived radon daughters in this section relates to the decay of. specific The daughter isotopes in the upper left corner by adding the chemical symbol of the quality of its numbers. In the lower right corner of the spiked symbol RnDP 222,220 refers to the corresponding figures All radon daughter isotopes (RnDP222 means 218Po, 214Pb, 214Bi, 214Po, RnDP220 refers 216Po, 212Pb, 212Bi, 212Po, 208Tl). All nuclear data used in this section are taken from ICRP38, the publication is mainly applied to radiation protection measuring instruments. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 13163.4-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 13163.4-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 13163.4-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 13163.4-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |