GB/T 13163.3-2014 English PDFUS$434.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 13163.3-2014: Radiation protection instrumentation -- Radon and radon decay product measuring instruments -- Part 3: Specific requirements for radon decay product measuring instruments Status: Valid
Basic dataStandard ID: GB/T 13163.3-2014 (GB/T13163.3-2014)Description (Translated English): Radiation protection instrumentation -- Radon and radon decay product measuring instruments -- Part 3: Specific requirements for radon decay product measuring instruments Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: F84 Classification of International Standard: 13.280 Word Count Estimation: 22,296 Date of Issue: 9/3/2014 Date of Implementation: 2/1/2015 Quoted Standard: IEC 60050-394; IEC 60068-2-27; IEC 61000-6-4; IEC 61140; IEC 61187; ISO/IEC GUIDE 98-3-2008 Adopted Standard: IEC 61577-3-2011, IDT Regulation (derived from): People's Republic of China Announcement of Newly Approved National Standards No. 21 of 2014 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This Standard specifies the measure outdoor, residential and workplace (including underground mines) in the volume of activity of airborne short-lived radon progeny and/or its potential environmental �� concentration instrument specific requirements. This GB/T 13163.3-2014: Radiation protection instrumentation -- Radon and radon decay product measuring instruments -- Part 3: Specific requirements for radon decay product measuring instruments---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Radiation protection instrumentation Radon and radon decay product measuring instruments Part 3. Specific requirements for radon decay product measuring instruments ICS 13.280 F84 National Standards of People's Republic of China Radiation protection instrumentation - Radon and radon measuring instrument Part 3. Particular requirements for radon measuring instruments measuringinstruments-Part 3. Specificrequirementsforradondecayproduct (IEC 61577-3.2011, IDT) Issued on. 2014-09-03 2015-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released Table of ContentsIntroduction Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 designed considering 3 4.1 pairs of measuring design considerations 3 4.2 Operation and Maintenance design considerations 3 5 technical part 5 5.1 The sampling device 5 5.2 radiation detection device 5 5.3 Data processing and recording 5 5.4 Measurement display 5 5.5 Power 6 6 Test conditions 6 6.1 Overview 6 6.2 6 standard test conditions 6.3 Test for 6 6.4 test source 7 7 radiation detection performance requirements and tests 7 7.1 pairs of the reference source in response to the test 7 7.2 Other radon isotopes crosstalk 7 Linear value of 7.3 indicates 8 7.4 Instrument statistical fluctuation 8 7.5 Response Time 9 7.6 signal accumulation 9 8 air circuit performance requirements and test 10 8.1 Overview 10 8.2 10 flow stability The accuracy of flow measurement 10 8.3 8.4 Filter Pressure Drop 10 8.5 indicates a low sampling flow value 11 9 environmental performance requirements and test 11 9.1 pairs in response to environmental γ radiation 11 9.2 aerosol concentration 11 9.3 Ambient temperature 11 9.4 relative humidity and condensation water 12 9.5 atmospheric pressure 12 10 electrical performance requirements and tests 12 10.1 Warm-up time 12 12 10.2 Power Changes 10.3 Battery Test 13 11 mechanical performance requirements and test 13 13 11.1 Requirements 11.2 Test Method 13 12 Operation and Maintenance Manual 13 13 type test reports and certificates 14 Table 1 Reference conditions and standard test conditions (unless otherwise noted manufacturer) 14 Table 2 test radiation detection performance of 15 Table 3 with the impact of the change in the test 15 16 Table 4 air circuit testForewordGB/T 13163 "Radiation protection instrumentation - Radon and radon measuring instrument" is divided into four parts. --- Part 1. General principles; --- Part 2. Particular requirements for radon measuring instruments; --- Part 3. radon measuring instruments special requirements; --- Part 4. generating device containing radon isotopes and their daughters reference atmosphere (radon test system). This section GB/T 13163 Part 3. This section drafted in accordance with GB/T 1.1-2009 given rules. This section uses the translation method is equivalent to using IEC 61577-3.2011 "Radiation protection instrumentation - Radon and radon measuring instruments Part 3. Radon Particular requirements daughter meter. " Consistency correspondence with international standards in this part of the country cited the following documents. --- GB/T 2423.5-1995 Environmental testing for electric and electronic products Part 2. Test methods Test Ea and guidance. Shock (Idt IEC 60068-2-27. 1987); --- GB 17799.4-2012 Electromagnetic compatibility - Generic standards Emission standard for industrial environments (IEC 61000-6-4.2011, IDT); --- GB/T 16511-1996 Electrical and electronic measuring equipment - Documentation (idt IEC 61187.1993). For ease of use, this section of IEC 61577-3.2011 made the following editorial changes. --- "2 Normative references" to increase the GB/T 13163.1-2009; --- "3 Terms and definitions" increase "for ease of use, repeat the following list of IEC 60050-394 some terms and definitions Righteousness "; --- Remove 10.2 and Table 3 does not meet the conditions of the mains frequency content; --- Table 1, footnote number with a, b, c instead of *, **, ***, Table 2 and Table 3, footnote number with a, b instead of *, **. This part of the National Nuclear Instrument Standardization Technical Committee (SAC/TC30) and focal points. This section drafted by. China Institute of Atomic Energy. The main drafters of this section. Xing rain, extraordinary capacity, Yang Jing, Wei Kexin.IntroductionRadon is a radioactive trace gases, the earth's crust are radioactive series of natural radionuclides 238U, 235U and 232Th daughter of 226Ra, 223Ra And 224Ra decay produced. Isotopes of radon (222Rn, 219Rn and 220Rn) by three decay chain decay, and finally terminates in the stable lead with Isotope. Isotopes of radon and thoron 220Rn commonly referred to as 1). Note. Under normal circumstances, due to the very short half-life of 219Rn, compared with the two other series of radon activity, its activity and decay daughters (RnDP2)) activity Can be ignored, its health effects are not important. Therefore, in this part of 219Rn and its decay daughters is not considered. Radon decay of short-lived isotopes and their respective daughters (RnDP) (for example, 222Rn of 218Po, 214Pb, 214Bi, 214Po, 220Rn of 216Po, 212Pb, 212Bi, 212Po, 208Tl) is very important, as they form public and occupational radiation exposure of staff to accept the natural home To section. In some people the workplace (for example, underground mine, mineral water and waterworks) work by a very significant level of radon Exposure. Radon is a gas and its isotopes and their daughter are fine particles of these different amounts of airborne radionuclides are present in the form. High accuracy Measurement of natural radioactivity in the atmosphere of this level for health physics is valuable. Since these radioactive elements in the air and in phase The measuring instrument should have unique behavioral characteristics, it is necessary to test methods for measuring instruments such norms. GB/T 13163 series of standards, including radon and radon testing and calibration of measuring instruments special requirements in order to facilitate application, GB/T 13163 Series of standards are divided into the following different parts. GB/T 13163.1 (normative). This section relates specializes in radon and radon (RnDP) The term measurements with the unit, briefly RnDP for radon measurement and test equipment and calibration of radon test system (STAR). GB/T 13163.2 (normative). This section is dedicated to 222Rn and 220Rn meter test. GB/T 13163.3 (normative). This section is dedicated to the 222Rn and 220Rn daughters (RnDP222 and RnDP220) meter test. GB/T 13163.4 (normative). This section details the structure and application of the STAR test. GB/T 13163.5 (informative). This part is about the characteristics of radon and its daughters and technical guidelines of the measure. 1) This section does not use the term thoron, radon represents nuclides 220Rn and 222Rn. Especially when a particular radionuclide, marked its chemical symbol and mass number. 2) RnDP is an acronym for radon decay products, sometimes represented by radon daughters. Radon decay products or its abbreviation RnDP refers to this section concern radon decay All short-lived progeny. For a particular daughter isotopes in the upper left corner plus the quality of its chemical symbol numbers. Symbol RnDP plus right The subscript numbers (222,220) refers to the corresponding isotopes of radon daughters all. (For example, RnDP222 means of 222Rn daughters 218Po, 214Pb, 214Bi, 214Po, RnDP220 means of 220Rn daughters 216Po, 212Pb, 212Bi, 212Po, 208Tl). Radiation protection instrumentation - Radon and radon measuring instrument Part 3. Particular requirements for radon measuring instruments1 ScopeGB/T 13163 provisions of this part of the measure outdoor, residential and workplace (including underground mines) in the air carrier's short-lived radon daughters Product activity and/or special environmental requirements α potential concentration of the instrument. This section applies to crawl based on sampling, continuous sampling measurement technology and electronic integration of almost all types of electronic equipment. Correct Activity measurement sampling means (such as filters) can be performed on or after sampling during the sampling period is completed. GB/T 13163.1-2009 laid down in the various types of instruments used to measure.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. IEC 60050-394 International Electrotechnical Vocabulary (IEV) - Part 394. Nuclear instrumentation equipment, systems, equipment and detectors (Interna- tionalelectrotechnicalvocabulary (IEV) -Part 394. Nuclearinstrumentation-Instruments, systems, equipmentanddetectors) IEC 60068-2-27 Environmental testing Part 2-27. Tests - Test Ea and guidance. Shock (Environmentaltesting- Part 2-27. Tests-TestEaandguidance. Shock) IEC 61000-6-4 Electromagnetic compatibility (EMC) Part 6-4. Generic standards Emission standard for industrial environments (Electromag- neticcompatibility (EMC) -Part 6-4. Genericstandards-Emissionstandardforindustrialenviron- ments) - General IEC 61140 Protection against electric shock devices and equipment (Protectionagainstelectricshock-Commonas- pectsforinstalationandequipment) IEC 61187 Electrical and electronic measuring equipment - Documentation (Electricalandelectronicmeasuringequipment- Documentation) ISO /IEC Guide 98-3.2008 Uncertainty of measurement - Part 2. Guide to the Expression of Uncertainty in Measurement (GUM.1995)3 Terms and DefinitionsAs defined in IEC 60050-394 and the following terms and definitions apply to this document. For ease of use, repeat the following list IEC 60050-394 some terms and definitions. 3.1 The amount of conventional true value conventionalytruevalueofaquantity Given the value of a specific amount, according to the value for a given purpose uncertainty has sometimes conventionally acceptable. Note. The "conventional true quantity value" is sometimes referred to as a given value, best estimate, conventional value or reference value. [IEC 60050-394.2007, 394-40-10 defined] ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 13163.3-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 13163.3-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 13163.3-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 13163.3-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |