GB 31534-2015: The norm of energy consumption per unit product of p-xylene
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 31534-2015169 Add to Cart 3 days The norm of energy consumption per unit product of p-xylene Valid

Similar standards

GB 31335   GB 31823   GB 31830   GB 31533   GB 12021.2   

Basic data

Standard ID: GB 31534-2015 (GB31534-2015)
Description (Translated English): The norm of energy consumption per unit product of p-xylene
Sector / Industry: National Standard
Classification of Chinese Standard: F01
Classification of International Standard: 27.010
Word Count Estimation: 8,883
Date of Issue: 2015-05-15
Date of Implementation: 2016-06-01
Quoted Standard: GB/T 2589; GB/T 12497; GB/T 12723; GB/T 13462; GB/T 13466; GB 17167; GB 18613; GB 19153; GB 19761; GB 19762; GB 20052; GB/T 23331; SH/T 1486.1-2008
Regulation (derived from): National Standard Announcement 2015 No. 15
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Standard specifies the naphtha, hydrocracker gasoline as the main raw material to produce paraxylene unit product energy consumption (the energy) the technical requirements of quotas, statistical coverage and calculation methods and energy management measures. This Standard applies to the calculation of production of para-xylene as the main products of the enterprise unit product energy consumption, assessment, as well as new or renovation and expansion project of energy control.

GB 31534-2015: The norm of energy consumption per unit product of p-xylene

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
The norm of energy consumption per unit product of p-xylene ICS 27.010 F01 National Standards of People's Republic of China Xylene energy consumption per unit product Published 2015-05-15 2016-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China issued

Foreword

This standard 4.1 and 4.2 are mandatory, others are recommended. This standard was drafted in accordance with rules GB/T 1.1-2009 given. This standard Conservation and Environmental Protection, the Ministry of Industry and Information Technology Energy Saving and Comprehensive Utilization Department put forward by the National Development and Reform Commission resources. This standard by the National Energy Foundation and Management Standardization Technical Committee (SAC/TC20), China Petroleum and Chemical Industry Federation Centralized. Drafted by. China National Chemical Information Center, CNOOC Huizhou refinery refining subsidiary, Fujian Refining and Petrochemical Co., Ltd., Sheng Yi Dahua Petrochemical Co., Ltd., China National Petroleum Corporation Urumqi Petrochemical Company, China Sinopec Yangzi Petrochemical Co. the company. The main drafters. Blue Xiaoguang, Yufu Hai, Xu Qingping, Mei Zhipeng, Zhang Longjiang, Hou Zhang expensive, Wu Tengshou, Yang Shengdong, Fu Qiang, YAT Zhao Li, Wang Wu, Li Yongliang. Xylene energy consumption per unit product

1 Scope

This standard specifies naphtha, hydrocracked gasoline as the main raw material, the production of energy consumption per unit of product p-xylene (the energy consumption) limits The amount of the technical requirements, the scope of statistics and computational methods, energy conservation and management measures. This standard applies to calculate the production of para-xylene as the main product unit energy consumption of the enterprise, assessment, as well as new or renovation and expansion items Energy control purposes.

2 Normative references

The following documents for the application of this document is essential. For dated references, only applies to the version dated paper Pieces. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2589 comprehensive energy consumption computing General GB/T 12497 three-phase asynchronous motor economy GB/T 12723 energy consumption per unit product preparation General GB/T 13462 power transformer economic operation GB/T 13466 AC driven fan (pump, air compressor) General economic operation system GB 17167 energy use per unit of energy management and computing appliances with General GB 18613 sized three-phase asynchronous motor energy efficiency limit value and energy efficiency rating GB 19153 displacement air compressor energy efficiency and energy efficiency level limit value GB 19761 fan efficiency limit value and energy efficiency rating GB 19762 water pump energy efficiency limit value and energy evaluation GB 20052-phase distribution transformer efficiency limit value and energy efficiency rating GB/T 23331 Energy Management System Requirements SH/T 1486.1-2008 oil paraxylene

3 Terms and Definitions

GB/T 12723 defines the following terms and definitions apply to this document. 3.1 Paraxylene comprehensive energy consumption thecomprehensiveenergyconsumptionofproductp-xylene During the reporting period, the total amount of all kinds of energy para-xylene production process actually consumed. 3.2 Paraxylene comprehensive energy consumption per unit of product thecomprehensiveenergyconsumptionperuintproductofp-xylene Comprehensive energy consumption per unit of production of para-xylene product representation. 4. Technical Requirements 4.1 pairs of the unit energy consumption limit xylene Means conventional paraxylene unit energy should not exceed the limit value 700kgoe/t. 4.2 pairs of xylene unit product energy access value New or expansion paraxylene product energy value means access units should not exceed 530kgoe/t. 4.3 pairs of xylene advanced energy consumption per unit of product value Means energy consumption per unit of production xylene advanced value should not exceed 500kgoe/t. Statistical methods and calculation range 5 5.1 statistical range 5.1.1 Xylene comprehensive energy consumption including energy production system, auxiliary production system energy consumption and energy production systems subsidiary. a) producing energy consumption It comprises a pre-hydrogenation unit, a reformer unit, extraction unit, a fractionation unit xylene, toluene disproportionation and transalkylation unit, the adsorptive separation The main energy consumption of the production process and isomerization unit cell and the like. b) an auxiliary energy production system It includes a process for the production of system services, facilities and equipment, mainly for the power supply, machine repair, water, gas, heating, cooling, Miriam Repair, lighting energy, raw materials warehouse and factory space and security, environmental protection, energy consumption and other facilities. c) Affiliated energy production systems Departments and units of the production system specially configured production control system (factory) and the plant area for the production of services, primarily for scheduling Energy facility room, office, operating room, control room, lounge, locker rooms, baths, central control analysis, product testing, maintenance workers and other segments Source consumption. 5.1.2 paraxylene recovery using waste heat generated in the process, chemical reaction heat and I can not be included in the energy. If the waste heat, residual And the like capable of chemical reaction heat utilization by other means, it should be deducted from the actual utilization of energy in this system. 5.1.3 Energy consumption statistics, accounting should include the various production processes and systems should neither repeat, nor omission. 5.2 Calculation Method 5.2.1 calculate overall energy consumption should be consistent with the provisions of GB/T 2589's. 5.2.2 Thermal energy values are translated into a unified standard unit of measurement kg oil (kgoe). Calorific value of energy to various enterprises in the reporting period Calorific value of the measured subject, there is no actual conditions, refer to Appendix A or Appendix B in the reference oil standards off various energy conversion coefficient. The total overall energy consumption of various energy-xylene 5.2.3 (E) is equal to the consumption of the production process, the total outward subtracting various energy output Amount, the standard value in kilograms oil (kgoe), calculated according to formula (1). E = Σ i = 1 (Ei × Ki) -Σ j = 1 (Ej × Kj) (1) Where. --- E-xylene product of the value of the overall energy consumption in kilograms of standard oil (kgoe); EI --- i-th physical quantity of energy consumed in the production of para-xylene; EJ --- Energy j th physical quantity paraxylene production process output; Ki --- i-th coefficient of the input energy off of standard oil; KJ --- j th output energy Standard Oil off coefficient; M --- Number of kinds of energy input; --- n-number of types of energy outputs. Xylene comprehensive energy consumption per unit of product 5.2.4 (e), the reporting period is equal to the overall energy consumption divided by the product of p-xylene paraxylene reporting period Yield value in kg standard oil per ton (kgoe/t), calculated according to formula (2). e = (2) Where. E --- paraxylene value of comprehensive energy consumption per unit of product, in kilograms of standard oil per ton (kgoe/t); P --- p-xylene qualified products (to be consistent with SH/T 1486.1-2008 requirements) physical production, tonnes (t).

6 and energy management measures

6.1 basis of energy conservation management 6.1.1 should be established in accordance with GB/T 23331 energy management system, standardize energy management, continuous improvement of energy efficiency. 6.1.2 shall be equipped with energy measuring instruments according to the requirements of GB 17167, establish and improve the energy measurement management system to ensure basic energy data The accuracy and completeness. 6.2 energy-saving technology management 6.2.1 Economic Operation Production equipment used in general should reach the state of the economy, economic operation and management of the motor should be consistent with GB/T 12497 Regulations; economic operation and management of fans, pumps and air compressors shall comply with GB/T 13466; the economy of power transformers Operation and management should be consistent with GB/T 13462 of. A variety of network transmission medium, should comply with the relevant standards and technical requirements, and to strengthen the peacekeeping Care management, to prevent run, run, drip, leak phenomenon. 6.2.2 Energy Saving Technology Measures to encourage the use of energy-saving technologies, such as. a) heat integration and heat integration techniques; b) low-temperature heat exchanger pinch internet; c) furnace flue gas heat recovery, use of technology; d) transfer efficiency separation, heat exchange of mass and heat transfer technology; e) the efficient use of new catalysts, adsorbents replacement agents and clay, to reduce energy consumption process; f) a low temperature heat recovery, low pressure steam, low temperature hot water power generation technology. 6.2.3 energy-consuming equipment management In order to improve the level of energy, energy-consuming equipment to take the following companies deal with technical management measures. Enterprise should improve the energy efficiency of the motor system of the general-purpose equipment, with the elimination of high energy efficient equipment update energy-consuming equipment. Can effect the motor up GB 18613 to the energy level of the evaluation value; clean water centrifugal pump can reach the level of energy-saving effect evaluation value 19762 GB ; fan energy Effect evaluation value reaches the level of energy 19 761 GB ; air compressor can effect the volumetric energy evaluation value reaches 19153-GB Level. Enterprise should improve the energy efficiency of the power distribution device, it can reach the level of the distribution transformer effect evaluation value GB 20052 saving. Enterprises should improve the energy efficiency of the lighting system, the choice of the value of energy efficiency to meet the relevant energy efficiency standards for energy-saving evaluation value of lighting products. 6.3 Monitoring and evaluation Enterprises should strengthen management of energy metering, energy metering regulate behavior, according to the provisions of the supervision and inspection of measuring instruments, at the same time, strengthen energy consumption test Nuclear, strengthen the awareness of energy conservation, energy companies regularly audit and energy efficiency benchmarking.

Appendix A

(Informative) Reference Standard Oil off various energy factor table Standard Oil off various energy reference coefficients in Table A.1. Table A.1 off various energy factor table reference oil standards Number average calorific variety of standard oil off kg coefficient Remarks An electrical (equivalent value) 3600kJ/(kW · h) [860kcal/(kW · h)] 0.086kgoe/(kW · h) 2 Standard Oil a 41868MJ/t (10000Mcal/t) 1000kgoe/t 3 coal 29308MJ/t (7005Mcal/t) 700kgoe/t 4 fuel gas 39775MJ/t (9506Mcal/t) 950kgoe/t 5 fuel oil 41816MJ/t (10000Mcal/t) 1000kgoe/t 6 LPG 50179MJ/t (11993Mcal/t) 1200kgoe/t 7 LNG 51415MJ/t (12288Mcal/t) 1230kgoe/t 8 gasoline 43124MJ/t (10307Mcal/t) 1030kgoe/t 9 Kerosene 43124MJ/t (10307Mcal/t) 1030kgoe/t 10 diesel 42705MJ/t (10206Mcal/t) 1020kgoe/t 11 Industrial coke 33494MJ/t (8005Mcal/t) 800kgoe/t 12 10.0MPa stage steam 3852MJ/t (921Mcal/t) 92kgoe/t 7.0MPa≤pb 13 5.0MPa stage steam 3768MJ/t (900Mcal/t) 90kgoe/t 4.5MPa≤p < 7.0MPa 14 3.5MPa stage steam 3684MJ/t (880Mcal/t) 88kgoe/t 3.0MPa≤p < 4.5MPa 15 2.5MPa stage steam 3559MJ/t (851Mcal/t) 85kgoe/t 2.0MPa≤p < 3.0MPa 16 1.5MPa stage steam 3349MJ/t (800Mcal/t) 80kgoe/t 1.2MPa≤p < 2.0MPa 17 1.0MPa stage steam 3182MJ/t (763Mcal/t) 76kgoe/t 0.8MPa≤p < 1.2MPa 18 0.7MPa stage steam 3014MJ/t (720Mcal/t) 72kgoe/t 0.6MPa≤p < 0.8MPa 19 0.3MPa stage steam 2763MJ/t (660Mcal/t) 66kgoe/t 0.3MPa≤p < 0.6MPa 20 < 0.3MPa stage steam 2303MJ/t (550Mcal/t) 55kgoe/t 21 10 ℃ ~ 16 ℃ cold 0.42MJ (100Mcal) 0.010kgoe/MJ sensible heat cold 22 5 ℃ cold 0.67MJ (160Mcal) 0.016kgoe/MJ cooling phase the amount of 23 0 ℃ cold 0.75MJ (180Mcal) 0.018kgoe/MJ cooling phase the amount of 24 -5 ℃ cold 0.80MJ (190Mcal) 0.019kgoe/MJ cooling phase the amount of 25 -10 ℃ cold 0.88MJ (210Mcal) 0.021kgoe/MJ cooling phase the amount of 26 -15 ℃ cold 1.00MJ (240Mcal) 0.024kgoe/MJ cooling phase the amount of a fuel which should be translated into standard calorific oil; b steam pressure means gauge pressure.

Appendix B

(Informative) Working fluid off various energy factor table reference standard oil Off various energy refrigerant oil standard reference coefficients are shown in Table B.1. Table B.1 off various energy working medium standard reference oil coefficient table Variety No. of energy consumption per unit energy working fluid off coefficient kg standard reference oil 1 fresh water 6.28MJ/m3 (1500kcal/m3) 0.15kgoe/t GB/T 50441-2007 2 demineralized water 10.47MJ/t (2500kcal/t) 0.25kgoe/t GB/T 50441-2007 3 demineralized water 96.30MJ/t (23015kcal/t) 2.30kgoe/t GB/T 50441-2007 4 deoxygenated water 385.19MJ/t (92060kcal/t) 9.20kgoe/t GB/T 50441-2007 5 and condensing condensate 152.81MJ/t (36521kcal/t) 3.65kgoe/t GB/T 50441-2007 6 the heating device condensate 320.29MJ/t (76549kcal/t) 7.65kgoe/t GB/T 50441-2007 7 circulating water 4.19MJ/t (1001kcal/t) 0.10kgoe/t GB/T 50441-2007 8 compressed air (purge) 1.59MJ/m3 (380kcal/m3) 0.038kgoe/m3 GB/T 50441-2007 9 compressed air (non-purified) 1.17MJ/m3 (280kcal/m3) 0.028kgoe/m3 GB/T 50441-2007 10 nitrogen 6.28MJ/m3 (1500kcal/m3) 0.15kgoe/m3 GB/T 50441-2007
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 31534-2015_English be delivered?

Answer: Upon your order, we will start to translate GB 31534-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 31534-2015_English with my colleagues?

Answer: Yes. The purchased PDF of GB 31534-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service