Home   Cart   Quotation   Policy   About-Us
www.ChineseStandard.net
SEARCH

GB 31276-2014 English PDF

US$189.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 31276-2014: Minimum allowable values of energy efficiency and evaluating values of energy conservation of tungsten halogen lamps
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB 31276-2014189 Add to Cart 3 days Minimum allowable values of energy efficiency and evaluating values of energy conservation of tungsten halogen lamps Valid

Similar standards

GB 31335   GB 30978   GB 31823   GB 12021.2   GB 17167   GB 19762   

Basic data

Standard ID: GB 31276-2014 (GB31276-2014)
Description (Translated English): Minimum allowable values of energy efficiency and evaluating values of energy conservation of tungsten halogen lamps
Sector / Industry: National Standard
Classification of Chinese Standard: F01
Classification of International Standard: 27.010
Word Count Estimation: 8,812
Date of Issue: 10/10/2014
Date of Implementation: 9/1/2015
Quoted Standard: GB/T 14094; GB 14196.2; GB 14196.3; GB/T 26178
Regulation (derived from): People's Republic of China Announcement of Newly Approved National Standards 2014 No. 24
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Standard specifies the energy efficiency of household and similar general lighting with halogen lamps of limited value, energy conservation evaluation values ??and test methods. This Standard is applicable to the rated voltage is less than or equal t

GB 31276-2014: Minimum allowable values of energy efficiency and evaluating values of energy conservation of tungsten halogen lamps


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Minimum allowable values of energy efficiency and evaluating values of energy conservation of tungsten halogen lamps ICS 27.010 F01 National Standards of People's Republic of China Tungsten halogen lamps for general lighting energy efficiency limit And energy conservation evaluation values Issued on. 2014-10-10 2015-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

4.3 This standard is mandatory, the rest are recommended. This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard by the National Development and Reform Commission resource conservation and environmental protection, energy conservation and comprehensive utilization of Industry and Information Technology Ministry. This standard by the National Standardization Technical Committee for Energy and Management (SAC/TC20) centralized. This standard drafting units. China National Institute of Standardization, Osram (China) Lighting Co., Ltd., Zhejiang Shenghui Lighting Co., Ltd., Philips (China) Investment Co., Ltd., Kwong Ming Source Lighting Appliance Co., NVC Lighting Technology Co., Ltd., Foshan Electrical and Lighting Co. Shares the company. The main drafters of this standard. Zhao Yuejin, Zhangjun Bin, Lu Guangming, Yu Gaojie, Chengtai Song, Xiong Fei, Wei Bin. Tungsten halogen lamps for general lighting energy efficiency limit And energy conservation evaluation values

1 Scope

This standard specifies the limit values, evaluating values of energy conservation and energy efficiency test methods for domestic and similar general lighting with halogen lamps. This standard applies to the rated voltage is less than or equal to 24V, a power range of 5W ~ 100W; rated voltage of 220V ~ 250V, power Rates from non-directional 15W ~ 500W tungsten halogen lamps for general illumination. This standard does not apply to directional halogen lamps.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 14094 halogen lamps (non - vehicle) - Performance requirements GB 14196.2 lamps - Safety requirements - Part 2. domestic and similar general lighting with halogen lamps GB 14196.3 lamps - Safety requirements - Part 3. Tungsten halogen lamps (non-motorized vehicles) GB/T 26178 flux measurement method

3 Terms and Definitions

GB/T 14094 and defined by the following terms and definitions apply to this document. 3.1 The initial tungsten halogen light efficiency initialluminousefficacyfortungstenhalogenlamp Under standard test conditions, halogen measured initial luminous flux and the measured power ratio. 3.2 Halogen lamps energy efficiency limit minimumalowablevaluesofenergyefficiencyfortungstenhalogenlamp Under standard test conditions, the value of the minimum standard halogen lamps initial light effect achieved. 3.3 Halogen lamps energy conservation evaluation values evaluatingvaluesofenergyconservationfortungstenhalogenlamp Under standard test conditions, minimum standards for the initial value of energy-saving halogen lamps light effect achieved. 3.4 Halogen lamps Directional/non-directional halogen lamps directionalhalogenlamp/non-directionalhalogenlamp Lamps in solid angle of π steradian (sr) within (equivalent to 120 ° cone angle of the conical solid angle) more than 80% of the light output, known as directed Halogen lamps; on the contrary, is called non-directional halogen lamps. 4. Technical Requirements 4.1 Basic requirements This standard applies halogen lamps, their safety should be consistent with GB 14196.2 and GB 14196.3 requirements; performance should be consistent with GB/T 14094 Requirements. 4.2 defines the calculated value of energy efficiency halogen lamps and energy-saving evaluation value Halogen lamps and energy-saving energy efficiency limit value shall be evaluated formula (1) is calculated. η = (2b a2/P) - 4a2b/P a4/P2 2b2 (1) Where. η --- Initial luminous efficacy, in lumens per watt (lm/W); P --- rated power in watts (W); a, b --- constant (constant energy efficiency limit value and energy conservation evaluation values in Table 1). The calculated energy efficiency of limited value and energy after an evaluation of the value of decimal places after the decimal place value rounding. Table 1 defines the calculation of energy efficiency and energy conservation evaluation values constant value Initial luminous efficacy values coefficient Rated voltage ≤24V 220V ~ 250V Energy efficiency of limited value evaluating values of energy efficiency limit value of energy conservation evaluation values a 0.70 0.51 1 0.75 b 0.041 0.028 0.05 0.035 4.3 halogen lamps energy efficiency limit The initial tungsten halogen light effect in line with the formula (1) and Table 1 gives the constants calculated the energy efficiency of limited value, or Table 2, Table 3 shows the energy efficiency Limit. At the same time the life of halogen lamps shall meet the requirements of 4.5. 4.4 tungsten-halogen energy-saving evaluation value The initial tungsten halogen light effect in line with the formula (1) and Table 1 gives the constants of the calculated energy conservation evaluation values, or Table 2, Table 3 shows energy Evaluation value. At the same time the life of halogen lamps shall meet the requirements of 4.5. Table 2 halogen lamps energy efficiency of limited value and the initial luminous efficiency energy saving evaluation value (rated voltage ≤24V) in lumens per watt rated power efficiency Limit Energy Saving Evaluation value rated power efficiency Limit Energy Saving Evaluation value rated power efficiency Limit Energy Saving Evaluation value 5 5.9 10.0 14 10.0 16.2 23 12.0 19.1 6 6.6 11.0 15 10.3 16.6 24 12.2 19.4 7 7.1 11.9 16 10.5 17.0 25 12.4 19.6 8 7.7 12.7 17 10.8 17.3 26 12.5 19.8 9 8.1 13.4 18 11.0 17.7 27 12.7 20.0 10 8.6 14.1 19 11.3 18.0 28 12.8 20.2 11 9.0 14.7 20 11.5 18.3 29 13.0 20.4 12 9.3 15.2 21 11.7 18.6 30 13.1 20.6 13 9.7 15.7 22 11.9 18.9 31 13.2 20.8 TABLE 2 (cont.) Lumens per watt rated power efficiency Limit Energy Saving Evaluation value rated power efficiency Limit Energy Saving Evaluation value rated power efficiency Limit Energy Saving Evaluation value 32 13.4 21.0 55 15.4 23.7 78 16.5 25.3 33 13.5 21.1 56 15.4 23.8 79 16.6 25.4 34 13.6 21.3 57 15.5 23.9 80 16.6 25.4 35 13.7 21.5 58 15.5 24.0 81 16.6 25.5 36 13.8 21.6 59 15.6 24.1 82 16.7 25.5 37 13.9 21.7 60 15.7 24.2 83 16.7 25.6 38 14.0 21.9 61 15.7 24.2 84 16.8 25.6 39 14.1 22.0 62 15.8 24.3 85 16.8 25.7 40 14.2 22.2 63 15.8 24.4 86 16.8 25.7 41 14.3 22.3 64 15.9 24.5 87 16.9 25.8 42 14.4 22.4 65 15.9 24.5 88 16.9 25.8 43 14.5 22.5 66 16.0 24.6 89 16.9 25.9 44 14.6 22.6 67 16.0 24.7 90 17.0 25.9 45 14.6 22.8 68 16.1 24.7 91 17.0 26.0 46 14.7 22.9 69 16.1 24.8 92 17.0 26.0 47 14.8 23.0 70 16.2 24.9 93 17.1 26.1 48 14.9 23.1 71 16.2 24.9 94 17.1 26.1 49 15.0 23.2 72 16.3 25.0 95 17.1 26.2 50 15.0 23.3 73 16.3 25.0 96 17.2 26.2 51 15.1 23.4 74 16.4 25.1 97 17.2 26.2 52 15.2 23.5 75 16.4 25.2 98 17.2 26.3 53 15.2 23.6 76 16.4 25.2 99 17.3 26.3 54 15.3 23.7 77 16.5 25.3 100 17.3 26.4 Table 3 halogen lamps energy efficiency of limited value and the initial luminous efficiency energy saving evaluation value (rated voltage of 220V ~ 250V) Units of lumens per watt rated power efficiency Limit Energy Saving Evaluation value rated power efficiency Limit Energy Saving Evaluation value rated power efficiency Limit Energy Saving Evaluation value 15 6.7 10.6 20 7.6 12.0 25 8.4 13.1 16 6.9 10.9 21 7.8 12.2 26 8.5 13.3 17 7.1 11.2 22 8.0 12.5 27 8.7 13.4 18 7.3 11.5 23 8.1 12.7 28 8.8 13.6 19 7.5 11.7 24 8.3 12.9 29 8.9 13.8 Table 3 (Continued) units of lumens per watt rated power efficiency Limit Energy Saving Evaluation value rated power efficiency Limit Energy Saving Evaluation value rated power efficiency Limit Energy Saving Evaluation value 30 126 9.0 14.0 67 11.7 17.6 13.5 20.0 31 9.1 14.1 68 to 69 11.7 17.7 130 13.5 20.1 127 ~ 32 9.2 14.3 70 to 71 11.8 17.8 13.6 20.2 131 ~ 134 33 9.4 14.4 72 to 73 11.9 17.9 135 13.6 20.3 34 14.6 9.5 74 12.0 18.0 138 13.7 20.3 136 ~ 35 9.6 14.7 75 to 76 12.0 18.1 140 13.7 20.4 139 ~ 36 9.6 14.8 77 to 78 12.1 18.2 142 13.8 20.4 141 ~ 37 9.7 79 15.0 80 12.2 18.3 146 13.8 20.5 143 ~ 38 15.1 9.8 81 12.2 18.4 151 13.9 20.6 147 ~ 39 152 9.9 15.2 82 12.3 18.4 13.9 20.7 40 10.0 15.3 84 12.3 18.5 83 ~ 153 ~ 155 14.0 20.7 41 10.1 15.4 86 12.4 18.6 85 ~ 156 ~ 158 14.0 20.8 42 10.2 15.5 87 12.4 18.7 160 14.1 20.8 159 ~ 43 10.2 15.6 89 12.5 18.7 88 ~ 161 ~ 165 14.1 20.9 44 10.3 15.8 90 12.5 18.8 170 14.2 21.0 166 ~ 45 10.4 15.9 91 12.6 18.8 172 14.2 21.1 171 ~ 46 to 47 92 to 93 10.5 16.0 12.6 18.9 176 14.3 21.1 173 ~ 48 10.6 16.1 94 96 12.7 19.0 179 14.3 21.2 177 ~ 49 10.7 16.2 97 12.7 19.1 182 14.4 21.2 180 ~ 50 10.7 16.3 99 12.8 19.1 98 ~ 183 ~ 187 14.4 21.3 51 10.8 16.4 100 12.8 19.2 194 14.5 21.4 188 ~ 52 10.9 16.5 101 12.9 19.2 195 14.5 21.5 53 10.9 16.6 104 12.9 19.3 102 ~ 196 ~ 200 14.6 21.5 54 ~ 55 ~ 107 13.0 11.0 16.7 105 19.4 204 14.6 21.6 201 ~ 56 11.1 16.8 108 13.0 19.5 207 14.7 21.6 205 ~ 57 11.2 109 16.9 110 13.1 19.5 214 14.7 21.7 208 ~ 58 11.2 17.0 112 13.1 19.6 111 ~ 215 ~ 222 14.8 21.8 59 to 60 11.3 17.1 113 13.2 19.6 223 14.8 21.9 61 11.4 17.2 116 13.2 19.7 114 ~ 224 ~ 229 14.9 21.9 62 11.4 17.3 119 13.3 19.8 117 ~ 230 ~ 234 14.9 22.0 63 11.5 17.3 120 13.3 19.9 238 15.0 22.0 235 ~ 64 11.5 17.4 123 13.4 19.9 121 ~ 239 ~ 245 15.0 22.1 65 ~ 66 ~ 125 13.4 11.6 17.5 124 20.0 15.1 246 22.1 Table 3 (Continued) units of lumens per watt rated power efficiency Limit Energy Saving Evaluation value rated power efficiency Limit Energy Saving Evaluation value rated power efficiency Limit Energy Saving Evaluation value 247 255 15.1 315 22.2 320 15.6 22.8 411 16.0 23.5 256 to 257 15.1 321 22.3 330 15.6 22.9 428 16.1 23.5 412 ~ 258 ~ 331 ~ 333 265 15.2 22.3 15.7 22.9 435 16.1 23.6 429 ~ 266 ~ 334 ~ 270 15.2 22.4 347 15.7 23.0 448 16.2 23.6 436 ~ 271 to 275 15.3 22.4 348 15.7 23.1 462 16.2 23.7 449 ~ 276 ~ 349 ~ 283 15.3 22.5 361 15.8 23.1 469 16.3 23.7 463 ~ 284 ~ 362 ~ 285 15.4 22.5 368 15.8 23.2 490 16.3 23.8 470 ~ 286 ~ 296 ~ 377 15.4 22.6 369 15.9 23.2 491 16.4 23.8 297 ~ 378 ~ 298 15.4 22.7 388 15.9 23.3 500 16.4 23.9 492 ~ 299 ~ 389 ~ 393 308 15.5 22.7 16.0 23.3 - - - 309 ~ 394 ~ 410 314 15.5 22.8 16.0 23.4 - - - 4.5 life Life halogen lamps comply with the requirements of Table 4. Table 4 halogen lamps life requirements in hours Rated voltage ≤24V 220V ~ 250V Rated life ≥2000 ≥1000

5 Test methods

Initial luminous efficacy and life should be in accordance with Test Method GB/T 14094 stipulated in the test, in which the initial luminous flux according to GB/T 26178 test.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB 31276-2014_English be delivered?

Answer: Upon your order, we will start to translate GB 31276-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB 31276-2014_English with my colleagues?

Answer: Yes. The purchased PDF of GB 31276-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Refund Policy     Privacy Policy     Terms of Service