US$159.00 ยท In stock
Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB 26875.2-2011: [GB/T 26875.2-2011] Remote-monitoring system of urban fire protection -- Part 2: Functional requirements for communication server software
Status: Valid
| Standard ID | USD | BUY PDF | Lead-Days | Standard Title (Description) | Status |
| GB 26875.2-2011 | 159 |
Add to Cart
|
2 days
|
[GB/T 26875.2-2011] Remote-monitoring system of urban fire protection -- Part 2: Functional requirements for communication server software
| Valid |
Basic data
Standard ID: GB 26875.2-2011 (GB26875.2-2011)
Description (Translated English): [GB/T 26875.2-2011] Remote-monitoring system of urban fire protection -- Part 2: Functional requirements for communication server software
Sector / Industry: National Standard
Classification of Chinese Standard: C81
Classification of International Standard: 13.220.20
Word Count Estimation: 6,653
Date of Issue: 2011-07-29
Date of Implementation: 2012-05-01
Quoted Standard: GB/T 17544-1998; GB/T 26875.3-2011
Regulation (derived from): Announcement of Newly Approved National Standards No. 12 of 2011
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This Chinese standard relates to city fire remote monitoring system communication server software functionality requirements and test methods. This standard applies to the city fire remote monitoring system control center communications server software installation.
GB 26875.2-2011: [GB/T 26875.2-2011] Remote-monitoring system of urban fire protection -- Part 2: Functional requirements for communication server software
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Remote-monitoring system of urban fire protection.Part 2. Functional requirements for communication server software
ICS 13.220.20
C81
National Standards of People's Republic of China
City fire remote monitoring system
Part 2. Communications server software functionality requires
Part 2. Functionalrequirementsforcommunicationserversoftware
Issued on. 2011-07-29
2012-05-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
Part 3 of this chapter is mandatory, the rest are recommended.
GB 26875 "city fire remote monitoring system" is divided into six parts.
--- Part 1. User information transfer means;
--- Part 2. Communications server software functionality requires;
--- Part 3. alarm transmission network communication protocol;
--- Part 4. Basic data items;
--- Part 5. admissibility software functional requirements;
--- Part 6. information management software functional requirements.
This section GB Part of 226,875.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This part of the National Fire Fire Communications Standardization Technical Committee Technical Committee (SAC/TC113/SC14) centralized.
This section is responsible for drafting unit. Shenyang Fire Research Institute Ministry of Public Security.
Participated in the drafting of this section. Wansheng (China) Technology Co., Ltd., Gulf Fire Network Limited, Shenyang Mabel Control Co.,
Tongfang Co., Ltd., Guangdong 100 Xun Information Technology Co., Ltd., Shanghai VTech Communications, Jiangxi Shengan development of urban security information
Ltd., Beijing Science and Technology Development Co., Ltd. Qingdao WebEx.
The main drafters of this section. Liu Meihua, Qi Bao, Li Haitao, Guo Li governance, Yang Ying, Nie Wei, Tang Hao, Wang Yu-line, Gu Genlian, Yim,
Zou Maria, Liang Weifeng, Chen Xingyu, Deng Tao commentary, Jun.
City fire remote monitoring system
Part 2. Communications server software functionality requires
1 Scope
GB 26875 of the provisions of this part of the city fire remote monitoring system in communication server software functionality requirements and test methods.
This section applies to communications server software city fire remote monitoring system control center installation uses.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 17544-1998 Information technology - Software packages - Quality requirements and testing
GB/T 26875.3-2011 city fire remote monitoring system - Part 3. alarm transmission network communication protocol
3 Functional requirements
3.1 Communications server software to run or log on through, should automatically enter the normal working condition.
Communication protocols and user information transmission apparatus 3.2 Communication server software should be in accordance with GB/T 26875.3 specified data communication End
To the following functions.
a) receiving GB user information transmission means/T 26875.3-2011 information listed in 8.3.1, and forwarded to the receiving agent;
b) a user information transmission means addressing the GB/T 26875.3-2011 information listed in 8.3.2 is sent to the appropriate
A user information transmission means.
3.3 Communication server software should be able to monitor and user information transmission apparatus, receiving agents and other terminal equipment connected to a communication connection status,
When connected to a communication failure, should be able to archive and automatically notify the agent accepted.
Communications Server 3.4 software should be able to fire alarm backup link received user information transmission means, and forwarded to accept
Seats.
Communications Server 3.5 software should have the configuration and exit operation rights.
3.6 communications server software should be able to automatically record, query startup and exit time.
Communications Server 3.7 software interface shall meet the following requirements.
a) the use of Chinese display, the display should be expressed in clear, concise and easy to understand;
b) should be displayed with the call agent's link status;
c) should display the date and clock information.
Communications Server 3.8 user documentation software should meet the GB/T 17544-1998 of 3.2 requirements.
Test Method 4
4.1 General
4.1.1 provide communications server software package and user documentation from the test side.
4.1.2 test, in accordance with the relevant requirements of the user documentation for hardware configuration and software installation, connection-related system equipment, complete software, each
Entry is set so that the relevant system equipment in proper working condition.
4.1.3 meet the following requirements of the software under test is qualified, otherwise unqualified.
a) the tested software is not an exception occurs during the test;
The computer running the software under test b) during the test does not restart, do not dawdle (dead) machine;
c) Test results shall meet the requirements of Chapter 3.
4.2 Method
4.2.1 Communications Server software is running, observe and record the communication server software automatically enter the working state of the case.
4.2.2 Send GB/T 26875.3-2011 information listed in 8.3.1 to the communication server from the user information transmission means, by receiving seat
Chairs observe and record the communication server software to receive and forward the above information; information transmission means to the user specified forwarding
GB/T 26875.3-2011 information listed in 8.3.2, observation and recording apparatus receives the user information transmission and execution information.
4.2.3 users are disconnected from the information transmission apparatus and a receiving agent, a physical connection to other terminals, observe and record the communication service
Recognition software to communicate with the connection is disconnected, normally connected to a communication failure after the notification of acceptance agents and archiving the case.
4.2.4 Disconnect the master link user information transmission means links, send a fire alarm from the user information transmission means to the communication server
Information received by the agent to observe and record the communication server software to receive and transmit information in that section.
Communication parameters 4.2.5 server software configuration operations, observe and record the communication server software is having an operation right configuration parameters
Limit; in the communications server software running state, conduct exit operation, observe and record the communication server software, whether operated exit
For permission.
4.2.6 observe and record the communication server software automatically records, query and exit a start time.
4.2.7 respectively start and exit certain operations receiving seats on the communications server software interface according to the instructions with user documentation
Off operations, archive records viewing operation, observe and record shows the communication server software interface.
......
Tips & Frequently Asked Questions:
Question 1: How long will the true-PDF of GB 26875.2-2011_English be delivered?
Answer: Upon your order, we will start to translate GB 26875.2-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time.
Question 2: Can I share the purchased PDF of GB 26875.2-2011_English with my colleagues?
Answer: Yes. The purchased PDF of GB 26875.2-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.
Question 3: Does the price include tax/VAT?
Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs):
List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?
Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.