HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189760 (7 Jun 2025)

English JJG 14-2016 PDF (JJG 14-1997: Older version)

Search result: JJG 14-2016 (JJG 14-1997 Older version)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
JJG 14-2016English419 Add to Cart 3 days [Need to translate] Non-self-indicating Weighing Instruments Valid JJG 14-2016
JJG 14-1997English359 Add to Cart 3 days [Need to translate] Verification regulation of nonself-indicating weighing instrument Obsolete JJG 14-1997
JJG 14-1985EnglishRFQ ASK 3 days [Need to translate] Movable Beam Balance Obsolete JJG 14-1985


BASIC DATA
Standard ID JJG 14-2016 (JJG14-2016)
Description (Translated English) Non-self-indicating Weighing Instruments
Sector / Industry Metrology & Measurement Industry Standard
Classification of Chinese Standard A53
Word Count Estimation 18,186
Date of Issue 3/3/2016
Date of Implementation 2016-09-03
Older Standard (superseded by this standard) JJG 14-1997
Quoted Standard JJG 99; JJF 1181
Regulation (derived from) Announcement No.26 of the General Administration of Quality Supervision, Inspection and Quarantine
Issuing agency(ies) State Administration of Quality Supervision, Inspection and Quarantine


JJG 14-2016 Non-self-indicating Weighing Instruments National Metrological Verification Regulation of the People's Republic of China Non-self-indicating scale 2016-03-03 release 2016-09-03 Implementation State Administration of Quality Supervision, Inspection and Quarantine issued Non-self-indicating scale Verification procedures Replacing JJG 14-1997 Responsible unit. National Weighing Measurement Technology Committee Drafting unit. Qingdao Weighing Test Center Ningbo Institute of Measurement and Testing Jiangsu Institute of Metrology Shandong Institute of Metrology This procedure entrusts the National Weighing Metrology Technical Committee to explain The main drafters of this procedure. Yu Xuguang (Qingdao Weighing Test Center) Yan Jianjun (Ningbo Institute of Measurement and Testing) Zhao feng (Jiangsu province metrology and scientific research institute) Ma Kun (Shandong Institute of Metrology) Participate in the drafters. Yu Jingfen (Qingdao Weighing Test Center) Liang Liang (Qingdao Weighing Test Center) table of Contents Introduction (II) 1 range (1) 2 References (1) 3 terms and units of measurement (1) 3.1 Terms (1) 3.2 Unit of measurement (1) 4 Overview (2) 5 Measurement performance requirements (2) 5.1 Division of accuracy levels (2) 5.2 Test division value (2) 5.3 The maximum allowable error of the scale (2) 5.4 Repeatability (3) 5.5 partial load (3) 5.6 zero (3) 5.7 Sensitivity (3) 6 General technical requirements (3) 6.1 Safety of measurement (3) 6.2 raising mound (3) 6.3 Metrology and marking of metrological instruments (3) 7 Metering device control (4) 7.1 Standard equipment for testing (4) 7.2 Verification Project (4) 7.3 Inspection of general technical requirements (4) 7.4 Measurement performance test (5) 7.5 Processing of test results (8) 7.6 Verification cycle (8) Appendix A Verification Record Format (Recommended) (1) (9) Appendix B Verification Record Format (Recommended) (2) (10) Appendix C Verification Certificate Page Format (Recommended) (11) Appendix D Test results Notification page format (recommended) (12) introduction The JJG 14-1997 "non-self-indicating scale" verification procedures are revised and executed in the preparation format The JJF1002-2010 "national measurement procedures for the preparation of rules" provisions. Compared with JJG 14-1997, in addition to compilation Modification of the main changes are the following. - Added some of the necessary terms related to metrological verification (see 3.1); - a legal unit of measurement that must be used for non-self-indicating scales (see 3.2); --- modified the sensitivity requirements (see 5.7); - Increased protection against deceptive use and protection of parts such as mound, mound, adjustment and other components (see 6.1); - a list of approved items (see 7.2); - modified inspection items in use (see 7.2); - Increased weighing calculation formula (see 7.4.4); - modified load requirements for repeatability tests (see 7.4.5); --- delete the partial load test "weighing the rolling load of the scale" of the relevant content; - the measurement of the lever is removed separately; --- provide the test record format and test certificate, the results of the notice within the page format (see Appendix A, B, C, D). The previous versions of this order are released as follows. --- JJG 14-1997; --- JJG 14-1985. Non - self - indicating scale inspection procedures 1 Scope This procedure is applicable to the first inspection of non-self-indicating scale (hereinafter referred to as scale) of accuracy level and general accuracy level Set, follow-up and check in use. 2 reference file JJG 99 weight JQF1181 Weighing Terms and Definitions For dated references, only the dated edition applies to this rule; references that are not dated , The latest version (including all amendments) applies to this procedure. 3 terms and units of measurement 3.1 terminology The terminology used in this procedure is consistent with the terminology of JJF1181 and is intended for ease of use and ease of use. Under the terms. 3.1.1 load load Due to gravity, the load on the scale of the loader is called the items, and sometimes directly refers to their force. Note. Loads include weights or other items with stable values. 3.1.2 carrier loadreceptor The part of the scale that is used to accept the load. 3.1.3 measurement lever weighinglever Equipped with a mound and/or balance nut, a load indicating component consisting of one or more levers. 3.1.4 increase mound slottedweight With a semicircular notch, so that it can be placed on the weight of the plate on a certain shape of the weight. 3.1.5 wandering poise Install or suspend the weight on the metering lever, which can be used in combination with the engraved line. It is often and measured on the lever The ruler marks together to indicate the weighing value. 3.1.6 arm than armratio Lever arm length ratio. Generally refers to the fulcrum to the focus of the distance divided by the fulcrum to the point of the distance from the business. 3.1.7 lead leadsealing A seal mark with a metal lead or lead alloy used to prevent any unauthorized modification of the scale. The physical markings of the whole or removed parts. Including the manufacturer's factory inspection qualified seal and the certification body of the test qualified Seal. 3.2 Units of measurement The units of measurement used in the scale shall be the legal units of measurement, including kilograms (kg), g (g) and t (t). ......

Similar standards: GB/T 36126   JJG 139   GB/T 1885   JJG 13   JJG 17   JJF 014