Powered by Google-Search & Google-Books Chinese Standards Shop Database: 169759 (Jan 19, 2020)
 HOME   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

SH/T 1499.4-2016

Chinese Standard: 'SH/T 1499.4-2016'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
SH/T 1499.4-2016English95 Add to Cart 0--15 minutes. Auto immediate delivery. Pure adipic acid - Determination of content of ash Valid SH/T 1499.4-2016
SH/T 1499.4-2016Chinese16 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]

  Google-Books (Full-PDF will be auto-delivered in 0~10 mins):   SH/T 1499.4-2016  SH/T 1499.7-2012  SH/T 1499.1-2012  SH/T 1499.10-2012  SH/T 1499.5-1997
In 0~10 minutes time, full copy of this English-PDF will be auto-immediately delivered to your email. See samples for translation quality.  
SH/T 1499.4-2016
SH
PETROCHEMICAL INDUSTRY STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
ICS 71.080.40
G 17
Filing No.. 55638-2016
Replacing SH/T 1499.4-1997
Pure adipic acid -
Determination of content of ash
精己二酸 第 4部分. 灰分的测定
ISSUED ON. JULY 11, 2016
IMPLEMENTED ON. JANUARY 1, 2017
Issued by. Ministry of Industry and Information Technology of the People’
Republic of China
Table of Contents
Foreword ... 3
1 Scope ... 5
2 Normative references ... 5
3 Method summary ... 5
4 Reagents and materials ... 5
5 Instruments and equipment ... 6
6 Sampling ... 6
7 Analysis steps ... 6
8 Expression of analysis results ... 7
9 Precision ... 7
10 Report ... 8
Foreword
SH/T 1499 “Pure adipic acid” is divided into the following parts.
- Part 1. Specification;
- Part 2. Determination of content - Titrimetric method;
- Part 3. Determination of chroma of ammonia solution - Spectrophotometric method;
- Part 4. Determination of content of ash;
- Part 5. Determination of content of iron - 2, 2’-Bipyridyl spectrophotometric method;
- Part 6. Determination of content of iron - Simple method;
- Part 7. Determination of content of nitric acid - Spectrophotometric method;
- Part 8. Determination of content of oxidizable compounds -Titrimetric method;
- Part 9. Measurement of melt colour (in Pt-Co scale);
- Part 10. Determination of content of moisture - Thermogravimetric method.
This Part is Part 4 of SH/T 1499.
This Part is drafted according to the rules given in ISO/IEC 1.1-2009.
This Part replaces SH/T 1499.4-1997 “Pure adipic acid - Determination of content of
ash”.
Compared with SH/T 1499.4-1997, the main changes of this Part are as follows.
- MODIFY the standard name;
- ADD detection limits for the method (see Clause 1 of this Part);
- CHANGE the balance’s scale division value from “0.1 mg” to “0.01 mg”; ADD the
requirements for the balance (see 5.1 of this Part, 5.1 of 1997 edition);
- CHANGE the amount of the weighed sample from “100 g” to “100 g or 200 g” (see
7.2 of this Part, Clause 7 of 1997 edition);
- CHANGE the fractional digit of the result from “1 mg/kg” to “0.1 mg/kg” (see 8.2 of
this Part, Clause 9 of 1997 edition);
- REDEFINE the reproducibility of the method and add the reproducibility (see 9.1
Pure adipic acid - Determination of content of ash
WARNING. This Standard is not intended to describe all safety issues related to
its use. It is the responsibility of the user to take appropriate safety and health
measures to ensure compliance with the relevant national regulations.
1 Scope
This Part specifies the gravimetric method for the determination of ash content in pure
adipic acid.
This Part applies to the determination of adipic acid with the ash content of not less
than 1 mg/kg.
2 Normative references
The following referenced documents are indispensable for the application of this
document. For dated references, only the dated edition cited applies. For undated
references, the latest edition of the referenced document (including all amendments)
applies.
GB/T 6678 General principles for sampling chemical products
GB/T 6679 General rules for sampling of solid chemical products
GB/T 6682 Water for laboratory use - Specifications
3 Method summary
IGNITE the sample in a platinum crucible or porcelain crucible, BURN the combustion
residue into ash at a (600 ± 50) °C muffle furnace, and then COOL and WEIGH.
4 Reagents and materials
Unless otherwise stated, all reagents are of analytical grade and the water used shall
comply with the grade three water specifications specified in GB/T 6682.
4.1 Hydrochloric acid solution (1 + 4).
7.2 Sample measurement
USE a balance (5.2) to weigh the sample, ACCURATE to 0.01 mg. WEIGH (100 ± 0.5)
g of sample when the ash content is more than 2 mg/kg. When the ash content is not
more than 2 mg/kg, WEIGH (200 ± 0.5) g of sample. PLACE the sample into the
constant-weight crucible; PLACE the crucible on the mud triangle; HEAT the sample
with alcohol torch from the bottom and around until the sample is all melted, and then
LIT the sample, REMOVE the heater, LET the sample natural burns until extinguishes.
NOTE. If 200 g sample is weighed, it will be processed twice.
PLACE the crucible in a (600 ± 50) °C muffle furnace; REMOVE after burning for 30
min; PLACE in a dryer to cool for 30 min; REMOVE; USE a balance (5.......