YS/T 710.6-2009: Method for chemical analysis of cobalt oxide. Part 6: Determination of calcium, cadmium, copper, iron, magnesium, manganese, nickel, lead, zinc content. Inductively coupled plasma-atomic emission spectromertry
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
YS/T 710.6-2009English110 Add to Cart 0-9 seconds. Auto-delivery Method for chemical analysis of cobalt oxide. Part 6: Determination of calcium, cadmium, copper, iron, magnesium, manganese, nickel, lead, zinc content. Inductively coupled plasma-atomic emission spectromertry Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: YS/T 710.6-2009
      

Similar standards

GB/T 3884.2   GB/T 3884.1   YS/T 710.2   

YS/T 710.6-2009: Method for chemical analysis of cobalt oxide. Part 6: Determination of calcium, cadmium, copper, iron, magnesium, manganese, nickel, lead, zinc content. Inductively coupled plasma-atomic emission spectromertry



---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YST710.6-2009
YS NONFERROUS METAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 77.120.70 H 13 Method for chemical analysis of cobalt oxide - Part 6: Determination of calcium, cadmium, copper, iron, magnesium, manganese, nickel, lead, zinc content - Inductively coupled plasma-atomic emission spectrometry ISSUED ON: DECEMBER 04, 2009 IMPLEMENTED ON: JUNE 01, 2010 Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Method summary ... 4 3 Reagents ... 4 4 Instruments ... 5 5 Analysis steps ... 5 6 Calculation of analysis result ... 6 7 Precision ... 6 8 Quality assurance and control ... 7

Foreword

YS/T 710, Method for chemical analysis of cobalt oxide, is divided into 6 parts: -- Part 1: Determination of cobalt content - Potentiometric method; -- Part 2: Determination of sodium content - Flame atomic absorption spectrometry method; -- Part 3: Determination of sulphur content - High frequency combustion- infrared absorption method; -- Part 4: Determination of arsenic content - Atomic fluorescence spectrometry; -- Part 5: Determination of silicon content - Molybdenum blue spectrophotometry; -- Part 6: Determination of calcium, cadmium, copper, iron, magnesium, manganese, nickel, lead, zinc content - Inductively coupled plasma- atomic emission spectrometry. This Part is Part 6 of YS/T 710. This Part shall be under the jurisdiction of National Technical Committee 243 on Nonferrous Metals of Standardization Administration of China. The responsible drafting organizations of this Part: Zhuzhou Smelter Group Company Limited. The drafting organizations of this Part: Ganzhou Cobalt Tungsten Co., Ltd. The participating drafting organizations of this Part: Zhuzhou Smelter Group Company Limited, Beijing General Research Institute of Mining & Metallurgy. The drafters of this Part: Wang Li, Liu Donglian, Wan Jianhong, Liu Yan, Yu Li, Liu Chunfeng. Method for chemical analysis of cobalt oxide - Part 6: Determination of calcium, cadmium, copper, iron, magnesium, manganese, nickel, lead, zinc content - Inductively coupled plasma-atomic emission spectrometry

1 Scope

This Part of YS/T 710 specifies the determination method of calcium, cadmium, copper, iron, magnesium, manganese, nickel, lead, zinc content in cobalt oxide. This Part applies to the determination of calcium, cadmium, copper, iron, magnesium, manganese, nickel, lead, zinc content in cobalt oxide. See Table 1 for the determination range Table 1 -- Determination range of each element

2 Method summary

Dissolve the sample in aqua regia; in a nitric acid medium, according to the optimized working conditions of the instrument and the optimized analysis spectrum, use a standard solution, which is similar to the sample composition, that matches with the cobalt matrix; use the ICP-AES instrument to determine the Ca, Cd, Cu, Fe, Mg, Mn, Ni, Pb, Zn content in the cobalt oxide.

3 Reagents

3.1 Hydrochloric acid (ρ1.19 g/mL), GR. 3.2 Nitric acid, (ρ1.42 g/mL), GR. 3.3 Aqua regia: 3 parts of hydrochloric acid (3.1) + 1 part of nitric acid (3.2). conditions, add 3 mL ~ 5 mL of perchloric acid (3.4) appropriately to smoke until it is nearly dry. 5.3.2 Blow in a small amount of water; cover the watch glass and boil; cool to room temperature; add 5 mL of nitric acid (3.2); transfer to a 100 mL volumetric flask; use water to dilute to the mark; shake well; use as a test solution for later use. 5.3.3 Measure each point mixed standard solution and test solution under the optimized working conditions of the instrument; the instrument automatically draws a working curve. 5.3.4 Test the to-be-tested solution and the blank.

6 Calculation of analysis result

6.1 The instrument, according to the standardization or calibrated standardization work curve and the set element, automatically processes the data, calculates and outputs the content of each measured element. 6.2 Keep two significant digits for the analysis result.

7 Precision

7.1 Repeatability For the measured values of the two independent test results that are obtained under repetitive conditions, within the average range that is given below, the absolute difference between the two test results does not exceed the repeatability limit (r); the case of exceeding the repeatability limit (r) is not more than 5%; the repeatability limit (r) is obtained by linear interpolation according to the data in Table 4. Table 4 -- Repeatability limit 7.2 Reproducibility For the measured values of the two independent test results that are obtained under reproductive conditions, within the average range that is given below, the absolute difference between the two test results does not exceed the reproducibility limit (R); the case of exceeding the reproducibility limit (R) is not Note: The repeatability limit (r) is 2.8Sr; Sr is the repeatability standard deviation. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of YS/T 710.6-2009 be delivered?

Answer: The full copy PDF of English version of YS/T 710.6-2009 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of YS/T 710.6-2009_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 710.6-2009_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- YS/T 710.6-2009 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of YS/T 710.6-2009?

A step-by-step guide to download PDF of YS/T 710.6-2009_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "YS/T 710.6-2009".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9