HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

YS/T 1229.3-2018 PDF English

US$165.00 · In stock · Download in 9 seconds
YS/T 1229.3-2018: Methods for chemical analysis of crude nickel hydroxide - Part 3: Determination of copper, cobalt, manganese calcium, magnesium, zinc, iron, aluminum, lead, arsenic and cadmium contents - Inductively coupled plasma atomic emission spectrometry
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
YS/T 1229.3-2018English165 Add to Cart 0-9 seconds. Auto-delivery Methods for chemical analysis of crude nickel hydroxide - Part 3: Determination of copper, cobalt, manganese calcium, magnesium, zinc, iron, aluminum, lead, arsenic and cadmium contents - Inductively coupled plasma atomic emission spectrometry Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: YS/T 1229.3-2018
      

Similar standards

YS/T 1149.5   GB/T 3884.2   GB/T 3884.1   YS/T 1229.2   

YS/T 1229.3-2018: Methods for chemical analysis of crude nickel hydroxide - Part 3: Determination of copper, cobalt, manganese calcium, magnesium, zinc, iron, aluminum, lead, arsenic and cadmium contents - Inductively coupled plasma atomic emission spectrometry



---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YST1229.3-2018
YS NONFERROUS METAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 77.120.40 H 13 Methods for chemical analysis of crude nickel hydroxide - Part 3: Determination of copper, cobalt, manganese, calcium, magnesium, zinc, iron, aluminum, lead, arsenic and cadmium contents - Inductively coupled plasma atomic emission spectrometry ISSUED ON: APRIL 30, 2018 IMPLEMENTED ON: SEPTEMBER 01, 2018 Issued by: Ministry of Industry and Information Technology of PRC

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Method summary ... 4 3 Reagents ... 5 4 Instrument ... 7 5 Specimen ... 8 6 Analytical procedures ... 8 7 Calculation of analysis results ... 10 8 Precision ... 11 9 Test report ... 12

Foreword

YS/T 1229-2018 "Methods for chemical analysis of crude nickel hydroxide" is divided into 4 parts: - Part 1: Determination of nickel content - Dimethylglyoxime gravimetric method; - Part 2: Determination of cobalt content - Flame atomic absorption spectrometric method; - Part 3: Determination of copper, cobalt, manganese calcium, magnesium, zinc, iron, aluminum, lead, arsenic and cadmium contents - Inductively coupled plasma atomic emission spectrometry; - Part 4: Determination of chlorine content - Turbidimetric method. This Part is Part 3. This Part was drafted in accordance with the rules given in GB/T 1.1-2009. This Part was proposed by AND shall be under the jurisdiction of the National Technical Committee for Standardization of Nonferrous Metals (SAC/TC 243). The responsible drafting organization for this Part: Zhejiang Huayou Cobalt Co., Ltd., Jinchuan Group Co., Ltd. Drafting organizations of this Part: Jinchuan Group Co., Ltd., Zhejiang Huayou Cobalt Co., Ltd., Beikuang Testing Technology Co., Ltd., Guangdong Industrial Analysis and Testing Center, Jingmen Greenme New Materials Co., Ltd., Quzhou Huayou Cobalt New Materials Co., Ltd., Jiangxi Copper Co., Ltd. The main drafters of this Part: Ren Lihua, Yu Shengjie, Guo Zelin, Wen Zhanjie, Lv Qingcheng, Xie Baihua, Zhu Zhenqing, Fan Juanhui, Liu Chunfeng, Fang Di, Zhuang Aichun, Wang Jin, Li Ju, Li Lei, Yao Weijie, Peng Feng, Guo Hui. Methods for chemical analysis of crude nickel hydroxide - Part 3: Determination of copper, cobalt, manganese, calcium, magnesium, zinc, iron, aluminum, lead, arsenic and cadmium contents - Inductively coupled plasma atomic emission spectrometry

1 Scope

This Part specifies the determination method of copper, cobalt, manganese, calcium, magnesium, zinc, iron, aluminum, lead, arsenic, and cadmium in crude nickel hydroxide. This Part is applicable to the determination of copper, cobalt, manganese, calcium, magnesium, zinc, iron, aluminum, lead, arsenic, cadmium in crude nickel hydroxide. The determination range is shown in Table 1.

2 Method summary

The test samples are decomposed with hydrochloric acid, nitric acid, hydrofluoric acid, perchloric acid. The emission intensity of each element is measured on an inductively coupled plasma atomic emission spectrometer in a dilute hydrochloric acid medium; the mass fraction of each element is calculated according to the working curve method. 3.12 Calcium standard stock solution: Weigh 2.500 g of calcium carbonate (standard, pre-dried at 105 °C ~ 110 °C to constant weight, placed in a desiccator to cool to room temperature) in a 250 mL beaker; add 20 mL of hydrochloric acid (3.2); cover with a watch glass; heat to dissolve; boil to remove carbon dioxide; transfer to a 1000 mL volumetric flask after cooling; use water to dilute it to the mark; mix well. 1 mL of this solution contains 1 mg calcium. 3.13 Magnesium standard stock solution: Weigh 1.6582 g of magnesium oxide (WMgO ≥ 99.95%, pre-calcined at 800 °C to constant weight, placed in a desiccator to cool to room temperature) in a 250 mL beaker; add a small amount of water to moisten; add 10 mL of hydrochloric acid (3.2); cover with a watch glass; dissolve completely at low temperature; transfer to a 1000 mL volumetric flask after cooling; use water to dilute it to the mark; mix well. 1 mL of this solution contains 1 mg of magnesium. 3.14 Standard stock solution of zinc: Weigh 0.1000 g of metallic zinc (wZn ≥ 99.95%); place it in a 400 mL beaker; add 20 mL of nitric acid (3.4); cover with a watch glass; dissolve completely at low temperature; rinse the watch glass and the wall of the beaker with water; heat and boil to expel nitrogen oxides. Remove and cool it; transfer to a 1000 mL volumetric flask; use water to dilute it to the mark; mix it. 1 mL of this solution contains 0.1 mg of zinc. 3.15 Standard stock solution of iron: Weigh 0.1430 g of ferric oxide (reference); place it in a 400 mL beaker; add 15 mL of hydrochloric acid (3.1); cover with a watch glass; heat at low temperature to dissolve completely; cool and transfer to a 1000 mL volumetric flask; use water to dilute it to the mark; mix it. 1 mL of this solution contains 0.1 mg of iron. 3.16 Aluminum standard stock solution: Weigh 0.1000 g of aluminum (wAl ≥ 99.95%); place in a 400 mL beaker; add 50 mL of hydrochloric acid (3.2); cover with a watch glass; heat at low temperature to dissolve completely; cool and transfer to a 1000 mL volumetric flask; use water to dilute it to the mark; mix it. 1 mL of this solution contains 0.1 mg aluminum. 3.17 Lead standard stock solution: Weigh 0.1000 g of lead (wPb ≥ 99.95%); place in a 400 mL beaker; add 20 mL of nitric acid (3.4); cover with a watch glass; dissolve completely at low temperature; cool and transfer to a 1000 mL volumetric flask; use water to dilute it to the mark; mix it. 1 mL of this solution contains 0.1 mg lead. 3.18 Arsenic standard storage solution: Weigh 0.1320 g of arsenic trioxide (standard, pre-dried at 100 °C ~ 105 °C for 1 h, placed in a dryer and cooled to room temperature) in a 100 mL beaker; add 5 mL of sodium hydroxide solution (3.7); cover with a watch glass; heat at low temperature until completely dissolved; add 5 mL of water and 2 drops of phenolphthalein ethanol solution (3.8); neutralize with hydrochloric acid (3.2) until the red color just disappears; then add 2 mL in excess; transfer to a 1000 mL volumetric flask; use water to dilute it to the mark; mix well. 1 mL of this solution contains 0.1 mg of arsenic. 3.19 Cadmium standard stock solution: Weigh 0.1000 g of metallic cadmium (wCd ≥ 99.95%); place it in a 500 mL beaker; add 20 mL of nitric acid (3.3); cover with a watch glass; dissolve completely at low temperature; cool and transfer to a 1000 mL volumetric flask; use water to dilute it to the mark; mix it. 1 mL of this solution contains 0.1 mg of cadmium. 3.20 Copper, cobalt, manganese mixed standard solution: Pipette 20.00 mL of copper, cobalt, manganese standard stock solutions (3.9 ~ 3.11), respectively, into a 200 mL volumetric flask; add 10 mL of hydrochloric acid (3.2); use water to dilute it to the mark; mix it. 1 mL of this solution contains 100 µg of copper, cobalt, manganese, respectively. 3.21 Mixed standard solution of calcium and magnesium: Pipette 20.00 mL of calcium and magnesium standard stock solutions (3.12 and 3.13) into a 200 mL volumetric flask; add 10 mL of hydrochloric acid (3.2); use water to dilute it to the mark; mix well. 1 mL of this solution contains 100 μg of calcium and magnesium, respectively. 3.22 Mixed standard solution of copper, cobalt, manganese, calcium, magnesium: Pipette 10.00 mL of copper, cobalt, manganese mixed standard solution (3.20) and 10.00 mL of calcium and magnesium mixed standard solution (3.21), into a 100 mL volumetric flask; add 5 mL of hydrochloric acid (3.2); use water to dilute it to the mark; mix well. 1 mL of this solution contains 10 μg of copper, cobalt, manganese, calcium, magnesium, respectively. 3.23 Mixed standard solution of zinc, iron, aluminum: Pipette 20.00 mL of zinc, iron, aluminum standard stock solutions (3.14 ~ 3.16) into a 200 mL volumetric flask; add 10 mL of hydrochloric acid (3.2); dilute to the mark with water; mix it. 1 mL of this solution contains 10 μg of zinc, iron, aluminum, respectively. 3.24 Mixed standard solution of lead and arsenic: Pipette 20.00 mL of lead and arsenic standard stock solutions (3.17 and 3.18) into a 200 mL volumetric flask; add 10 mL of hydrochloric acid (3.2); dilute to the mark with water; mix it. 1 mL of this solution contains 10 μg of lead and arsenic, respectively. 3.25 Cadmium standard solution: Pipette 2.00 mL of cadmium standard stock solution (3.19) into a 200 mL volumetric flask; add 10 mL of hydrochloric acid (3.2); use water to dilute it to the mark; mix it. 1 mL of this solution contains 1 μg of cadmium.

4 Instrument

Inductively coupled plasma atomic emission spectrometer - Under the best working conditions of the instrument, the relative standard deviation of the light intensity of each element does not exceed 2.5% when the standard solution with the lowest concentration (not the "zero" concentration standard solution) is used for 11 measurements. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of YS/T 1229.3-2018 be delivered?

Answer: The full copy PDF of English version of YS/T 1229.3-2018 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of YS/T 1229.3-2018_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 1229.3-2018_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- YS/T 1229.3-2018 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of YS/T 1229.3-2018?

A step-by-step guide to download PDF of YS/T 1229.3-2018_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "YS/T 1229.3-2018".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9