HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

QC/T 1134-2020 PDF English

US$215.00 · In stock · Download in 9 seconds
QC/T 1134-2020: Engine intake air water separation test procedure
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
QC/T 1134-2020English215 Add to Cart 0-9 seconds. Auto-delivery Engine intake air water separation test procedure Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: QC/T 1134-2020
      

Similar standards

QC/T 1163   QC/T 1164   QC/T 1133   QC/T 1186   

QC/T 1134-2020: Engine intake air water separation test procedure

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/QCT1134-2020
QC AUTOMOBILE INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 43.060.20 T 13 Engine intake air water separation test procedure ISSUED ON: AUGUST 31, 2020 IMPLEMENTED ON: JANUARY 01, 2021 Issued by: Ministry of Industry and Information Technology of PRC Annex: Number, name and date of implementation of 8 automobile industry standards No. Standard number Standard name Replaced standard number Date of implementation 166 QC/T 1131-2020 Methods of detecting polycyclic aromatic hydrocarbons in automotive materials 2021-01-01 167 QC/T 1132-2020 Measurement methods of the noise of electric power train system for electric vehicles 2021-01-01 168 QC/T 1134-2020 Engine intake air water separation test procedure 2021-01-01 169 QC/T 1133-2020 Safety filter element of air filter for commercial automobile 2021-01-01 170 QC/T 770-2020 Dry air filter assembly for automobile QC/T 770-2006 2021-01-01 171 QC/T 1135-2020 Water filter for automobile engine 2021-01-01 172 QC/T 793-2020 Air filters for motorcycles and scooters QC/T 793-2007 2021-01-01 173 QC/T 794-2020 Internal-combustion engine industry filter paper QC/T 794-2007 2021-01-01

Table of Contents

Foreword ... 5 Introduction ... 6 1 Scope ... 7 2 Normative references ... 7 3 Terms and definitions ... 7 4 Test equipment ... 7 5 Measurement accuracy ... 9 6 Test conditions ... 10 7 Test procedure ... 10 8 Technical conditions ... 13 Appendix A (Informative) Measurement method of particle size of water droplet ... 14 References ... 17 Engine intake air water separation test procedure

1 Scope

This document specifies the test method of air water separation performance, of the air/water separation device in the engine air intake system, including the technical conditions of air water separation efficiency, test equipment, test requirements, test conditions, test procedures, calculation of water separation efficiency. This document is applicable to the device in the air intake system, which has the water separation function, the pre-filter (coarse filter) of the air filter, the air filtration device with the water separation requirement, the intake air filtration system of heavy-duty engine, the automobile air intake system. Internal combustion engine's air intake system and industrial air intake system may refer to this document.

2 Normative references

The contents of the following documents constitute the indispensable clauses of this document through normative references in the text. Among them, for dated reference documents, only the version corresponding to that date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document. GB/T 28949-2012 Inlet air cleaning equipment for internal combustion engines and compressors - Performance testing QC/T 32-2017 Test methods of air cleaners for automobiles

3 Terms and definitions

There are no terms and definitions, that need to be defined in this document.

4 Test equipment

4.1 Test bench The typical layout of the test bench is as shown in Figure 1. Use the test devices, which are specified in Figure B.7, Figure B.12, Figure B.16 of GB/T 28949-2012, a) The accuracy of water flow measurement is ±5% of the actual value. b) The accuracy of nozzle pressure measurement is ±1 kPa. c) The accuracy of water temperature measurement is ±1.0 °C. d) When measuring the mass of the water added, separated, collected, the accuracy of the measurement shall be within ±1% of the weighing value or 1 g, whichever is greater.

6 Test conditions

6.1 In order to reduce the maintenance of the nozzle AND avoid the impact of performance changes, it shall, according to the nozzle manufacturer’s specifications, select the test water OR use the water, which has a conductivity of less than 20 µs/cm; the water temperature shall be kept within ±2 °C of the air intake temperature of the tested system. 6.2 This document does not involve water evaporation for the time being. The influence of water evaporation can be reduced, by controlling the water temperature. In order to keep the consistency of the test results AND reduce the influences, which are caused by the evaporation of water entering the tested system, it shall control the temperature and humidity of the test air. Meanwhile, the temperature of the air entering the air filter and separator shall be 23 °C ± 5 °C, the relative humidity shall be 55% ± 15%, the spray water temperature shall be 20 °C ± 10 °C. It shall be confirmed that, before the start of the test OR before the water injection spray, the conditions of the environment, air intake and water meet the specified requirements.

7 Test procedure

7.1 The purpose of the test is mainly to install inertial separation and its combination devices, in the air intake piping system, AND to evaluate the air filter's air intake housing components. Normally, clean components and clean filter elements shall be used for testing. 7.2 Install the air filter and intake system, according to the schematic diagram in Figure 1. 7.3 According to the test air flow, follow the requirements of Table 2, to select the water filling rate of nozzle. water filling rate to fill water, until the specified amount of 4000 g of water is filled. a) It shall record the time, BETWEEN commissioning AND the start of the test of water separation efficiency, which shall not exceed 10 min. b) If the water spraying stops for more than 10 minutes, it shall carry out the commissioning again, in accordance with the provisions of 7.9. 7.12 After filling at least 4000 g of water into the air/water separator, stop filling water. 7.12.1 After the test system continues to run for 30 s ± 2 s, close the air flow. 7.12.2 When the air flow is zero, wait for at least 5 minutes, until the drain of the test system completely stops dripping (whichever meets the requirement first). 7.12.3 Determine the amount of water filled AND the amount of water, which is separated by the tested system. 7.13 Weigh the mass of the filter element of air filter, before and after the test. Use the weighed cloth, to collect the remaining water in the housing, from which it may roughly estimate the water separation efficiency. 7.14 The water separation efficiency is calculated according to formula (1): Water separation efficiency = (The amount of water collected by the separation device + The amount of water separated by the separation device) / Water filling amount by the water filling device x 100% …………………………… (1) Where: Water filling amount - The total water amount minus the mass of water, which is collected outside the air inlet. 7.15 Repeat the steps from 7.10 to 7.13, for at least 3 times, until the repeatability of the air flow and water filling conditions meet the requirements each time. Follow the steps in 7.9, to repeatedly adjust the position of the container, to ensure the consistency of the efficiency test. The entire test, which is carried out according to the steps 7.10 ~ 7.13, shall be completed within 10 minutes; otherwise, it shall adjust the test time AND make it consistent, which is carried out according to 7.9, before the start of test according to the steps of 7.10. 7.16 The recorded test data shall include the following: a) Air flow; b) Water filling rate; c) Nozzle model and manufacturer; d) The number of nozzles used; e) Water and air pressure; f) Water temperature; g) Orifice size; h) Water droplet's size (it shall meet the manufacturer’s specifications or laboratory test requirements); i) Room temperature and relative humidity; j) Increased value of filter element's pressure drop; k) The time between adjustment and efficiency test; l) The time FROM when the air flow is stopped TO when all the water is collected and weighing; m) The number of test runs; n) The water separation efficiency of each test, which shall include the standard deviation and average value of all the data of the 3 tests. If necessary, the test data shall also include the initial mass and final mass of the main filter element; o) The distance and angle between the nozzle and the air inlet.

8 Technical conditions

For the engine air intake water separation device, the water separation efficiency, which is measured according to this test method, shall not be less than 80%. ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of QC/T 1134-2020 be delivered?

Answer: The full copy PDF of English version of QC/T 1134-2020 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of QC/T 1134-2020_English with my colleagues?

Answer: Yes. The purchased PDF of QC/T 1134-2020_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- QC/T 1134-2020 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of QC/T 1134-2020?

A step-by-step guide to download PDF of QC/T 1134-2020_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "QC/T 1134-2020".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9