NY/T 1975-2010 PDF in English
NY/T 1975-2010 (NY/T1975-2010, NYT 1975-2010, NYT1975-2010)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
NY/T 1975-2010 | English | 190 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
Water-soluble fertilizers. Determination of amino-acids content
| Valid |
Standards related to (historical): NY/T 1975-2010
PDF Preview
NY/T 1975-2010: PDF in English (NYT 1975-2010) NY/T 1975-2010
NY
AGRICULTURE INDUSTRY STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
ICS 65.080
G 20
Water-soluble fertilizers - Determination of amino-
acids contents
ISSUED ON: DECEMBER 23, 2010
IMPLEMENTED ON: FEBRUARY 01, 2011
Issued by: The Ministry of Agriculture of PRC
Table of Contents
Foreword ... 3
1 Scope ... 4
2 Normative references ... 4
3 Determination of free amino acid content - Amino acid automatic analyzer
method (arbitration method) ... 4
4 Determination of free amino acid content - Pre-column derivatization-liquid
chromatography method ... 7
Water-soluble fertilizers - Determination of amino-
acids contents
1 Scope
This standard specifies the automatic amino acid analyzer method and pre-
column derivatization-liquid chromatography method for the determination of
free amino acids in water-soluble fertilizers.
This standard applies to the determination of free amino acid content in liquid
or solid water-soluble fertilizers.
2 Normative references
The following documents are essential to the application of this document. For
the dated documents, only the versions with the dates indicated are applicable
to this document; for the undated documents, only the latest version (including
all the amendments) are applicable to this standard.
GB/T 8170 Rules of rounding off for numerical values & expression and
judgement of limiting values
HG/T 2843 Chemical fertilizer products - Standard volumetric, standard,
reagent and indicator solutions for chemical analysis
NY/T 887 Density testing of liquid fertilizer
3 Determination of free amino acid content - Amino
acid automatic analyzer method (arbitration method)
3.1 Principle
After precipitating the protein from the specimen by the use of sulfosalicylic acid,
the EDTA complexes metal elements are used to release amino acids. The
amino acids are separated by a separation column, to develop color with
ninhydrin, to determine the contents of totally 17 amino acids: aspartic acid,
threonine, serine, glutamic acid, Proline, glycine, alanine, cystine, valine,
methionine, isoleucine, leucine, tyrosine, phenylalanine, lysine, histidine,
arginine. The sum of these amino acids is the content of free amino acids.
3.2 Reagents and materials
The preparation of reagents, water and solutions used in this standard shall
comply with the provisions of HG/T 2843 unless otherwise specified for the
specifications and preparation methods.
3.2.1 Sodium citrate (Na3C6H5O7 • 2H2O).
3.2.2 Hydrochloric acid.
3.2.3 Hydrochloric acid solution: c(HCl) = 0.06 mol/L.
3.2.4 Sodium hydroxide solution: ρ (NaOH) = 500 g/L.
3.2.5 Sulfosalicylic acid solution: ρ (C6H6O6S • 2H2O) = 50 g/L.
3.2.6 Disodium edetate solution: ρ (EDTA-Na) = 10 g/L.
3.2.7 Sodium citrate buffer: pH 2.2. Weigh 19.6 g of sodium citrate (3.2.1).
Dissolve it. Pipette it to a 1000 mL volumetric flask. Add 16.5 mL of hydrochloric
acid (3.2.2). Add water to the mark. Mix it uniformly. If necessary, it may use
hydrochloric acid (3.2.2) and sodium hydroxide solution (3.2.4) to adjust the pH
to 2.2.
3.2.8 Mixed amino acid standard solution, chromatographically pure. It contains
total 17 amino acids: aspartic acid, threonine, serine, glutamic acid, Proline,
glycine, alanine, cystine, valine, methionine, isoleucine, leucine, tyrosine,
phenylalanine, lysine, histidine, arginine.
3.3 Instruments
3.3.1 Commonly used laboratory instruments.
3.3.2 Automatic amino acid analyzer.
3.3.3 Centrifuge (above 10000 r/min) or 0.45 µm microporous membrane, filter
and syringe.
3.3.4 Steam drying device: Test tube concentrator or other concentration device.
3.4 Analytical procedures
3.4.1 Preparation of specimens
After the solid sample has been reduced several times, take out about 100 g.
Grind it quickly to make all pass through a 0.50 mm aperture sieve (if the sample
is wet, it may pass a 1.00 mm sieve). Mix it evenly. Put it in a clean, dry container.
After multiple shaking of the liquid sample, quickly take about 200 mL and place
After precipitating the protein of specimen by sulfosalicylic acid, use the EDTA
to make the metal element release the amino acid. The amino acid is chemically
derivatized and separated by liquid chromatography to determine the contents
of totally 17 amino acids: aspartic acid, threonine, serine, glutamic acid, Proline,
glycine, alanine, cystine, valine, methionine, isoleucine, leucine, tyrosine,
phenylalanine, lysine, histidine, arginine. The sum of these amino acids is the
content of free amino acids in the fertilizer.
4.2 Reagents and materials
The preparation of reagents, water and solutions used in this standard shall
comply with the provisions of HG/T 2843 unless otherwise the specifications
and preparation methods are indicated.
4.2.1 Sulfosalicylic acid solution: ρ (C7H6O6S • 2H2O) = 50 g/L.
4.2.2 Disodium edetate solution: ρ (EDTA - Na) = 10 g/L
4.2.3 Mixed amino acid standard solution, chromatographically pure. It contains
total 17 amino acids: aspartic acid, threonine, serine, glutamic acid, Proline,
glycine, alanine, cystine, valine, methionine, isoleucine, leucine, tyrosine,
phenylalanine, lysine, histidine, arginine.
4.2.4 Reagents required by the selected derivatization method.
4.3 Instruments
4.3.1 Commonly used laboratory instruments.
4.3.2 Centrifuge (above 10000 r/ min) or 0.45 µm microporous membrane and
filter, syringe.
4.3.3 Liquid chromatograph, equipped with UV detector.
4.3.4 The equipment required for the selected derivative method.
4.4 Analytical procedures
4.4.1 Preparation of specimen
After the solid sample has been reduced several times, take about 100 g and
quickly grind it to pass through a 0.50 mm aperture sieve (if the sample is wet,
it can pass through a 1.00 mm sieve). Mix it evenly. Place it in a clean, dry
container. After shaking the liquid sample many times, quickly take about 100
mL and place it in a clean, dry container.
4.4.2 Preparation of sample solution
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|