JB/T 9249-1999: PDF in English (JBT 9249-1999)

JB/T 9249-1999 JB MACHINERY INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 17.120 N 12 Replacing ZB N12 008-89 Vortex shedding flow transducer ISSUED ON. AUGUST 6, 1999 IMPLEMENTED ON. JANUARY 1, 2000 Issued by. State Bureau of Machine Building Industry Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Definitions ... 5  4 Product category ... 6  5 Technical requirements ... 9  6 Test methods ... 12  7 Inspection rules ... 18  8 Mark, packaging and storage ... 19  Foreword This Standard is the revision of ZB N12 008-89 “Vortex shedding flow transducer”. There is no main technical differences between this Standard and ZB N12 008- 89. Only editorial changes are made on the basis of the previous standard. From the implementation date of this Standard, ZB N12 008-89 is replaced by this Standard. This Standard was proposed by and shall be centralized by National Industrial Process Measurement and Control Standardization Technical Committee. The drafting organization of this Standard. Shanghai Institute of Process Automation Instrumentation. Vortex shedding flow transducer 1 Scope This Standard specifies the definition, product category, technical requirements, test methods and inspection rules of vortex shedding flow transducer. This Standard is applicable to liquid and gas vortex shedding flow transducers with pulse signal output (hereinafter referred to as the transducer). It is also applicable to the transducer of vortex shedding flow transmitter with standardized signal output as well as the transducer of vortex shedding flowmeter with flow display. 2 Normative references The following standards contain the provisions which, through reference in this Standard, constitute the provisions of this Standard. At the publication of this Standard, the editions indicated are valid. All standards shall be revised. The parties who use this Standard shall explore the possibility of using the latest version of the following standards. GB 191-1990 Packaging - Pictorial marking for handling of goods GB/T 2555-1981 Pipe flange connectors for ordinary use - Mounting dimensions GB/T 2556-1981 Pipe flanges for ordinary use - Sealing surfaces - Forms and dimensions GB 3836.1-1983 Electrical apparatus for explosive atmosphere - General requirements GB 3836.2-1983 Electrical apparatus for explosive atmosphere - Flameproof electrical apparatus “d” GB 3836.3-1983 Electrical apparatus for explosive atmosphere - Increased safety electrical apparatus “e” GB 3836.4-1983 Electrical apparatus for explosive atmospheres - Intrinsically safe circuits and electrical apparatus “i” GB/T 9248-1988 Methods of evaluating the performance of flowmeters for incompressible fluids GB/T 15464-1995 General-purpose specification for the packaging instrumentation products JB/T 9329-1999 Basic environmental conditions and testing methods for instruments transportation and storage in the transportation 3 Definitions This Standard uses the following definitions. 3.1 Vortex shedding flow transducer Flow transducer that adopts placing an un-streamlined vortex body in fluid. The fluid alternatively separates and releases two strings of vortex on both sides of the vortex body, which are regularly and crisscross lined. Within a certain range, vortex’s separation frequency is proportional to the flow. And the vortex frequency can be detected by various types of detectors. It comprises of housing, vortex body, detecting element and amplifier. 3.2 Amplifier The device that amplifies and reforms the signal output by detecting element. 3.3 Meter factor The number of pulses output from per unit volume of fluid through the sensor. 3.4 Mean meter factor The arithmetic mean value of the maximum value and the minimum value among meter factors of each measurement point, within the predetermined flow range, represented by K . 3.5 Resistance factor Factor relating to pressure loss when the fluid goes through the transducer, represented by Cd. 3.6 Linearity The degree of consistency between calibration curve and stipulated line, i.e., the ratio BETWEEN the half value of the maximum value and the minimum value AND the average meter factor, represented by percentage. Gas. air under 20°C and 101325Pa. 4.2.5 Range The transducer’s range shall be selected from the following numeral systems. 6, 7, 8, 10, 11, 12, 15, 20, 25, 30. 4.2.6 Measured mediums The measured mediums shall comply with the requirements in Table 2. Table 2 Measured medium Gas-liquid universal Liquid Gas Mark number 1 2 3 4.2.7 Temperature range The transducer’s range of working temperature shall be selected among the following numeral systems of upper temperature limit and lower temperature limit. Upper temperature limit. 50, 80, 120, 200, 250, 300, 400°C; Lower temperature limit. 0, -10, -20, -40, -80, -120, -200°C. Thermal vortex shedding flow transducer’s absolute value of the difference between the upper limit and the lower limit temperature shall be greater than 50°C. 4.2.8 Power supply The transducer’s power supply shall use AC power supply of which the frequency is 50 HZ; the root-mean-square voltage is 220 V. It may also use DC power supply. DC power supply voltage shall be selected from the following numeral systems. 12, 24, (36) V. Note. Values in brackets are not recommended to use. 4.2.9 Output signal The transducer’s output signal is pulse signal, in which. Voltage pulse. low level 2V; high level 6V. Current pulse. low level is 4mA±0.25mA; high level is 20mA±1mA. resistance coefficient shall not be greater than 2.4. 5.6 Compressive strength The transducer shall be able to withstand the compressive strength test of 1.5 times nominal pressure and 5 min. There shall be no damage nor leakage. 5.7 Power supply voltage variation When power supply voltage varies between -15% ~ +10% of nominal value, the deviation BETWEEN meter factors of the transducer’s all measurements points AND the original calibrated average meter factor of this transducer shall be within the permissible basic error limit range, and comply with the requirements of 5.2, 5.3 and 5.4. 5.8 Power supply frequency variation When power supply frequency varies between -5% ~ +5% of rated value, the deviation BETWEEN meter factors of the transducer’s all measurements points AND the original calibrated average meter factor of this transducer shall be within the permissible basic error limit range, and comply with the requirements of 5.2, 5.3 and 5.4. (This article is only applicable to AC power supply transducer.) 5.9 Output signal When the transducer’s loading resistance varies within the range specified by the manufacturer, the level value of pulse signal shall comply with the requirements of 4.2.9. 5.10 Insulation resistance The insulation resistance among the transducer’s power supply terminal, output terminal and housing shall not be less than 20MΩ. 5.11 Insulation strength 5.11.1 DC power supply transducer Between the transducer’s power supply terminal and housing, between output terminal and housing, it shall withstand the insulation strength test of which the frequency is 50Hz, the voltage is 500V and the time is 1min. There shall be no breakdown or arcing. 5.11.2 AC power supply transducer Between the transducer’s power supply terminal and housing, between output terminal and housing, it shall withstand the insulation strength test of which the frequency is 50Hz, the voltage is respectively 1500V and 500V, and the time is 1min. There shall be no breakdown or arcing. 5.12 Effect of external magnetic field Under the effect of external magnetic field of which the frequency is 50Hz, and the magnetic field intensity is 400A/m, the deviation BETWEEN meter factors of the transducer’s all measurements points AND the original calibrated average meter factor of this transducer shall be within the permissible basic error limit range, and comply with the requirements of 5.2, 5.3 and 5.4. 5.13 Appearance The outer surface of the transducer shall be well treated. There shall be no peeling, flaking or other defects on the outer surface coating; no damage on the sealing surface; no loosening fasteners. All visible writings and symbols shall be clear. 5.14 Anti-transport environmental performance The transducer shall comply with the requirements in JB/T 9329 under the conditions of transport packaging. After the test, the deviation BETWEEN meter factors of the transducer’s all measurements points AND the original calibrated average meter factor of this transducer shall be within the permissible basic error limit range, and comply with the requirements of 5.2, 5.3, 5.4 and 5.6. The high temperature uses +55°C, the low temperature uses -40°C, falling shall be free fall and its height shall be 100mm. 5.15 Explosion-proof performance Explosion-proof performance of the explosion-proof transducer shall comply ... ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.