GB/T 4615-2013 PDF in English
GB/T 4615-2013 (GB/T4615-2013, GBT 4615-2013, GBT4615-2013)
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Name of Chinese Standard | Status |
GB/T 4615-2013 | English | 70 |
Add to Cart
|
0-9 seconds. Auto-delivery.
|
Poly (vinyl chloride) -- Determination of residual vinyl chloride monomer -- Gas-chromatographic method
| Valid |
GB/T 4615-2008 | English | 319 |
Add to Cart
|
3 days
|
Poly (vinyl chloride) -- Determination of residual vinyl chloride monomer content -- Gas chromatographic method
| Obsolete |
GB/T 4615-1984 | English | 319 |
Add to Cart
|
3 days
|
Determination method of residual vinyl chloride monomer contents in polyvinyl chloride
| Obsolete |
Standards related to (historical): GB/T 4615-2013
PDF Preview
GB/T 4615-2013: PDF in English (GBT 4615-2013) GB/T 4615-2013
ICS 83.080.20
G 32
GB
National Standard
of the People's Republic of China
Replacing GB/T 4615-2008
Poly (vinyl chloride) - Determination of residual vinyl
chloride monomer - Gas-chromatographic method
(ISO 6401.2008, Plastics - Poly (vinyl chloride) - Determination of residual vinyl
chloride monomer - Gas-chromatographic method, MOD)
聚氯乙烯
ISSUED ON. NOVEMBER 12, 2013
IMPLEMENTED ON. MAY 1, 2014
Issued by. General Administration of Quality Supervision, Inspection and
Quarantine of People's Republic of China;
China National Standardization Management Committee
Table of Contents
Preface ... 3
1 Scope ... 5
2 Normative references ... 5
3 Terms and definitions ... 5
4 Principles ... 6
5 Instruments ... 6
6 Reagents and materials ... 6
7 Sample preparation and storage ... 7
8 Steps ... 7
9 Result expression ... 9
10 Precision ... 9
11 Test report ... 9
Appendix A ... 11
Appendix B ... 12
Appendix C ... 14
Appendix D ... 15
Preface
This Standard is written in accordance with rules given in GB/T 1.1-2009.
This Standard replaces GB/T 4615-2008 "Poly (vinyl chloride). Determination of
residual vinyl chloride monomer content. Gas-chromatographic method".
Compared with GB/T 4615-2008, the major technical changes are as follows.
- MODIFY the Chinese name of the standard;
- ADJUST the scope of the standard (Chapter 1 of 2008 edition, Chapter 1
of this document);
- ADD chapter "Normative references";
- ADD chapter "Terms and Definitions";
- ADD "Warnings";
- ADJUST the structure of the standard and REMOVE method B;
- MODIFY the "sample weight and volume of solvent", "operational steps"
and "chloride standard solution preparation" and other technical content
( Chapter 5 of this document);
- ADD chapter "Precision";
- REVISE Appendix A (Appendix A of this document);
- REVISE Appendix B (Appendix B of this document);
- ADD Appendix C;
- ADD Appendix D.
This Standard uses redrafting method to modify and adopt ISO 6401.2008
"Plastics -- Poly(vinyl chloride) -- Determination of residual vinyl chloride
monomer -- Gas-chromatographic method”.
Compared with ISO 6401.2008, this Standard has adjusted the structure
considerably. Appendix C provides the changes and comparison list of chapter
number between this Standard and ISO 6401.2008.
There exists technical differences between this Standard and ISO 6401.2008.
Appendix D gives the list of differences and the corresponding technical reasons.
For ease of use, this Standard also makes the following editorial changes.
- USE "μg/g" to replace "mg/kg" as the unit of sample content of residual
vinyl chloride monomer;
- ADD Appendix C, PROVIDE the changes and comparison list of chapter
number between this Standard and ISO 6401.2008;
- ADD Appendix D, GIVE the list of differences and the corresponding
technical reasons.
This Standard is proposed by China Petroleum and Chemical Industry
Federation.
This Standard shall be administered by the National Standardization Technical
Committee - Plastic PVC Resin Product Branch (SAC/TC 15/SC 7).
Drafting organizations of this Standard. Xinjiang Zhongtai Chemical Co., Ltd.
and Jinxi Chemical Research Institute.
Main drafters of this Standard. Tan Chen, Liang Bin, Shi Yangqiu, and Wang
Xiaohong.
The previous standards replaced by this Standard are.
- GB/T 4615-1984, GB/T 4615-2008.
Poly (vinyl chloride) –
Determination of residual vinyl chloride monomer -
Gas-chromatographic method
Warning. The personnel who use this Standard shall have practical
experience of regular lab. This Standard does not indicate all possible
safety problems. Users are responsible for taking appropriate safety and
health practices and to ensure compliance with the relevant conditions of
the national regulations.
1 Scope
This Standard specifies the method that uses headspace gas-liquid
chromatography to determine the monomer content of residual vinyl chloride in
polyvinyl chloride (PVC).
This Standard applies to the determination of PVC resin and vinyl chloride
monomer content in its compound, the detection range is 0.1 μg/g - 3.0 μg/g.
2 Normative references
For application of this document, the following documents are essential. For
dated references, only the dated editions are applicable to this document. For
undated references, the latest editions (including any amendments) apply to this
document.
GB/T 2035 Plastic terms and their definitions (GB/T 2035-2008, ISO 472.1999,
IDT)
3 Terms and definitions
Terms and definitions defined in GB/T 2035 apply to this document.
4 Principles
DISSOLVE/SWELL PVC sample into N, N'-dimethylacetamide solvent, USE
headspace gas-liquid chromatography to determine vinyl chloride content in the
sample.
5 Instruments
General laboratory instruments and the following equipment.
5.1 Gas chromatography (GC).
5.2 Hydrogen flame ionization detector (FID).
5.3 GC column, the column shall be able to completely separate vinyl chloride
from impurities in the sample. The signal obtained from 0.01 mg/L of vinyl
chloride solution shall be at least three times of the baseline noise. Examples of
suitable chromatography column refer to Table A.1 of Appendix A. Other
equivalent chromatography column may also be chosen.
5.4 Data processing system, it is used for collecting data and processing gas
chromatography signal.
5.5 Thermostat, it can control at (70±1) ºC.
5.6 Glass bottles, the volume is 30 mL, with silicone septa and metal screw
sealing cap.
5.7 Glass bottles, common volume is (22.5±0.5) mL, with silicone septa and
metal screw sealing cap.
5.8 Glass pipettes, the volumes are 25 mL and 10 mL.
5.9 Micro syringes, the volumes are 500μL 100μL, or other suitable volume.
5.10 Glass gas-tight syringe, the volume is 10 mL, or other suitable volume.
5.11 Balance, accurate to 0.1 mg.
5.12 Balance, accurate to 0.01 g.
6 Reagents and materials
Reagents used are of analytical grade.
6.1 Vinyl chloride, purity is greater than 99.5%. Gas cylinders of vinyl chloride
shall be with syringe adapter.
b) The integral identification of the sample;
c) The single measured values and their arithmetic mean;
d) The difference with this Standard;
e) Testing personnel and date, etc.
equilibrium after more than
30 min of thermostat, with
accurate result, and
improving detection
efficiency
Appendix A
MODIFY the contents in
Appendix A of ISO
6401.2008
PROVID an appropriate gas-
chromatography column and
corresponding
chromatographic conditions.
It is suitable for China’s
conditions
Appendix B
Headspace injection’s
parameters in 8.2 and 8.3 of
ISO 6401.2008 8.2 are
integrated into Appendix B
According to the standard’s
needs
...... Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.
|