HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (23 Mar 2025)

GB/T 41559-2022 PDF English


Search result: GB/T 41559-2022
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 41559-2022English260 Add to Cart 0-9 seconds. Auto-delivery. Textiles - Determination of isothiazolone compounds Valid


PDF Preview: GB/T 41559-2022


GB/T 41559-2022: PDF in English (GBT 41559-2022)

GB/T 41559-2022 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 59.080.01 CCS W 04 Textiles - Determination of isothiazolone compounds ISSUED ON: JULY 11, 2022 IMPLEMENTED ON: FEBRUARY 01, 2023 Issued by: State Administration for Market Regulation; Standardization Administration of the People's Republic of China. Table of Contents Foreword ... 3  1 Scope ... 4  2 Normative references ... 4  3 Terms and definitions... 4  4 Principle ... 4  5 Reagents and materials ... 4  6 Instruments ... 5  7 Analysis steps ... 5  8 Result calculation and expression ... 7  9 Limit of quantitation ... 8  10 Precision ... 8  11 Test report ... 8  Annex A (normative) Chemical information of isothiazolone reference materials ... 9  Annex B (informative) Instrument analysis conditions ... 10  Annex C (informative) Multiple reaction monitoring chart (MRM) of isothiazolone standard substances ... 13  Annex D (informative) HPLC-DAD chromatograms and UV spectra of isothiazolone standard substances ... 14  Textiles - Determination of isothiazolone compounds 1 Scope This document describes the test method that uses high performance liquid chromatography-tandem mass spectrometer (HPLC-MS/MS) or high performance liquid chromatography-diode array detector (HPLC-DAD) to determine 7 isothiazolone compounds in textiles. This document applies to various textile products. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682, Water for analytical laboratory use - Specification and test methods 3 Terms and definitions There are no terms and definitions that need to be defined in this document. 4 Principle The specimen is extracted with methanol by ultrasonic. The extract is filtered through a membrane. Use high performance liquid chromatography-tandem mass spectrometer (HPLC-MS/MS) or high performance liquid chromatography-diode array detector (HPLC-DAD) to determine. Use external standard method for quantification. 5 Reagents and materials Unless otherwise specified, only analytically pure reagents are used, and the water is grade one water in accordance with GB/T 6682. 5.1 Methanol: Chromatographically pure. 5.2 Formic acid: Chromatographic pure; purity ≥98.0%. 5.3 Formic acid solution: 0.1%. Measure 1mL of formic acid (5.2). Dissolve in water and dilute to 1000mL. Shake well. 5.4 7 kinds of isothiazolone reference products: Purity ≥95%, in line with the provisions of Annex A. 5.5 Single-component standard stock solution: Accurately and separately weigh an appropriate amount of each isothiazolone separately product (5.4). Use methanol (5.1) to respectively prepare the standard stock solution of which the concentration is about 1000mg/L. NOTE: The standard stock solution shall be stored in a refrigerator at 0°C~4°C, protected from light. It is valid for 6 months. 5.6 Series mixed standard working solutions: Prepare as needed. Respectively pipette a certain volume of 7 isothiazolone standard stock solutions (5.5). Use methanol (5.1) to dilute step by step into a series of mixed standard working solutions of different concentrations. For example, When using HPLC-MS/MS, the concentrations are 2.0μg/L, 10.0μg/L, 50.0μg/L, 100.0μg/L, 500.0μg/L. When using HPLC-DAD, the concentrations are 0.2mg/L, 1.0mg/L, 5.0mg/L, 10.0mg/L, and 50.0mg/L. NOTE: The mixed standard working solution shall be stored in a refrigerator at 0°C~4°C, protected from light. It is valid for 1 month. 5.7 Membrane: Organic phase needle type, 0.22m. 6 Instruments 6.1 Analytical balance: Resolution is 0.01g and 0.1mg. 6.2 Reaction bottle: Tubular, with airtight stopper, about 50mL, made of hard glass. 6.3 Ultrasonic generator: The working frequency is 40kHz. The temperature control range is (40±5)℃. 6.4 High performance liquid chromatography-tandem mass spectrometer (HPLC- MS/MS): Equipped with an electrospray ionization source (ESI). 6.5 High performance liquid chromatograph (HPLC-DAD): Equipped with a diode array detector (DAD). 7 Analysis steps 7.1 Specimen preparation and handling Take a representative specimen. Cut into pieces about 5mm x 5mm. Mix well. Use the balance (6.1) to accurately weigh about 1g of the above specimen, accurate to 0.01g. absorption spectrum is consistent with the standard material, and the maximum absorption wavelength deviation is within the range of ±2nm, THEN the target analyte can be judged to be detected. The HPLC chromatograms and UV absorption spectra of 7 isothiazolones obtained under the analytical conditions given in Annex B are shown in Annex D. According to the content of the analyte in the specimen, select the mixed standard working solution (5.6) with similar response values for analysis. Take the peak area of the target compound as the ordinate, the concentration of the target compound as the abscissa, to draw a standard working curve. Perform quantitative calculation according to the external standard method. The response values of the analyte in the mixed standard working solution (5.6) and the test solution (7.1) shall be within the linear response range of the instrument. If the content exceeds the standard curve range, use methanol to dilute it to an appropriate concentration and analyze. 7.3 Blank test In the case of no specimen, follow steps 7.1~7.2. 8 Result calculation and expression Calculate the content of each isothiazolone in the textile according to formula (1). Round the calculation result to one decimal place. The test results are expressed in terms of the content of each isothiazolone. Where, Xi - The content of isothiazolone i in the specimen, in milligrams per kilogram (mg/kg); Ci - The mass concentration of isothiazolone i in the specimen solution read from the standard working curve, in milligrams per liter (mg/L); C0 - The mass concentration of isothiazolone i in the blank solution read from the standard working curve, in milligrams per liter (mg/L); V - The final volume of the specimen solution, in milliliters (mL); m - The mass of the specimen, in grams (g); f - The dilution factor. 9 Limit of quantitation The limit of quantification for the detection of 7 isothiazolones by HPLC-MS/MS is 0.1mg/kg. The limit of quantification for the detection of 7 isothiazolone compounds by HPLC-DAD is 1.0mg/kg. 10 Precision At a 95% confidence level, in the same laboratory, by the same operator using the same equipment, according to the same test method, test the same test object independently of each other in a short period of time. The absolute difference between the two test results obtained shall not be greater than 10% of the arithmetic mean of the two measured values. 11 Test report The test report shall at least give the following: a) Number of this document; b) Sample source and description; c) Instruments and methods used; d) Test results; e) Any details that deviate from this document; f) Test date. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.