HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (15 Sep 2024)

GB/T 3903.14-2021 PDF in English


GB/T 3903.14-2021 (GB/T3903.14-2021, GBT 3903.14-2021, GBT3903.14-2021)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 3903.14-2021English110 Add to Cart 0-9 seconds. Auto-delivery. Footwear -- Test methods for outsoles -- Needle tear strength Valid
Standards related to: GB/T 3903.14-2021
PDF Preview

GB/T 3903.14-2021: PDF in English (GBT 3903.14-2021)

GB/T 3903.14-2021 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 61.060 CCS Y 78 GB/T 3903.14-2021 / ISO 20874:2018 Replacing GB/T 3903.14-2005 Footwear - Test methods for outsoles - Needle tear strength (ISO 20874:2018, IDT) ISSUED ON: OCTOBER 11, 2021 IMPLEMENTED ON: MAY 01, 2022 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword ... 3  1 Scope ... 5  2 Normative references ... 5  3 Terms and definitions... 5  4 Test equipment and materials ... 6  5 Sampling and conditioning ... 7  6 Test methods ... 8  7 Test results ... 8  8 Test report ... 8  Footwear - Test methods for outsoles - Needle tear strength 1 Scope This document describes methods for determining the needle tear strength of footwear outsoles materials. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the version corresponding to that date is applicable to this document; for undated references, the latest version (including all amendments) is applicable to this document. ISO 7500-1 Metallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Calibration and verification of the force-measuring system ISO 17709 Footwear - Sampling location, preparation and duration of conditioning of samples and test pieces ISO 18454 Footwear - Standard atmospheres for conditioning and testing of footwear and components for footwear 3 Terms and definitions The following terms and definitions are applicable to this document. The addresses of terminology databases maintained by ISO and IEC for standardization are as follows: -- ISO online browsing platform: https://www.iso.org/obp -- IEC electronics development platform: http://www.electropedia.org/ 3.1 needle tear strength Divide the maximum force required to tear the material by the needle, by the thickness of the sample, to gain the needle tear strength. 2 – steel needle (ϕ1 mm); 3 – sample; a – thickness. Figure 1 – Example of clamps 4.4 Thickness gauge The thickness gauge shall have a firm base, and its presser foot shall have a constant weight load, which can be applied with a pressure of 10 kPa ± 3 kPa. The presser foot of the thickness gauge shall be a circular plane whose diameter is 10 mm ± 0.1 mm. The meter scale is 0.01 mm. 5 Sampling and conditioning Take samples in accordance with ISO 17709. Before testing, all samples shall be subjected to conditioning for at least 24 h according to ISO 18454. The sample is a long strip with a length of 50 mm ± 1 mm and a width of 20 mm ± 1 mm. The sample thickness shall preferably be: -- 2.0 mm ± 0.2 mm for polymer and elastic material solid core outsoles; -- 4.0 mm ± 0.2 mm for semi-foamed and foamed outsoles; -- original outsoles thickness for leather outsoles. Note: Take at least 3 points of equidistant distance from the center line parallel to the long side of the sample to measure the thickness of the sample; take the average value. Take at least 3 samples for testing. Use a suitable peeling machine to process the sample to uniform thickness. If feasible, the smooth original "skin" of the sample shall remain intact. The samples can be thus divided into the following 3 types: -- There are 2 original "skins", S2; -- There is 1 original "skin", S1; -- There is no original "skin", S0; The final results shall be based on the same type of samples, the sample type shall be recorded in the report. GB/T 3903.14-2021 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 61.060 CCS Y 78 GB/T 3903.14-2021 / ISO 20874.2018 Replacing GB/T 3903.14-2005 Footwear - Test methods for outsoles - Needle tear strength (ISO 20874.2018, IDT) ISSUED ON. OCTOBER 11, 2021 IMPLEMENTED ON. MAY 01, 2022 Issued by. State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of Contents Foreword... 3  1 Scope... 5  2 Normative references... 5  3 Terms and definitions... 5  4 Test equipment and materials... 6  5 Sampling and conditioning... 7  6 Test methods... 8  7 Test results... 8  8 Test report... 8  Footwear - Test methods for outsoles - Needle tear strength 1 Scope This document describes methods for determining the needle tear strength of footwear outsoles materials. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the version corresponding to that date is applicable to this document; for undated references, the latest version (including all amendments) is applicable to this document. ISO 7500-1 Metallic materials - Calibration and verification of static uniaxial testing machines - Part 1.Tension/compression testing machines - Calibration and verification of the force-measuring system ISO 17709 Footwear - Sampling location, preparation and duration of conditioning of samples and test pieces ISO 18454 Footwear - Standard atmospheres for conditioning and testing of footwear and components for footwear 3 Terms and definitions The following terms and definitions are applicable to this document. The addresses of terminology databases maintained by ISO and IEC for standardization are as follows. 3.1 needle tear strength Divide the maximum force required to tear the material by the needle, by the thickness of the sample, to gain the needle tear strength. 2 – steel needle (ϕ1 mm); 3 – sample; a – thickness. Figure 1 – Example of clamps 4.4 Thickness gauge The thickness gauge shall have a firm base, and its presser foot shall have a constant weight load, which can be applied with a pressure of 10 kPa ± 3 kPa. The presser foot of the thickness gauge shall be a circular plane whose diameter is 10 mm ± 0.1 mm. The meter scale is 0.01 mm. 5 Sampling and conditioning Take samples in accordance with ISO 17709.Before testing, all samples shall be subjected to conditioning for at least 24 h according to ISO 18454. The sample is a long strip with a length of 50 mm ± 1 mm and a width of 20 mm ± 1 mm. The sample thickness shall preferably be. -- 2.0 mm ± 0.2 mm for polymer and elastic material solid core outsoles; -- 4.0 mm ± 0.2 mm for semi-foamed and foamed outsoles; -- original outsoles thickness for leather outsoles. Note. Take at least 3 points of equidistant distance from the center line parallel to the long side of the sample to measure the thickness of the sample; take the average value. Take at least 3 samples for testing. Use a suitable peeling machine to process the sample to uniform thickness. If feasible, the smooth original "skin" of the sample shall remain intact. The samples can be thus divided into the following 3 types. -- There are 2 original "skins", S2; -- There is 1 original "skin", S1; -- There is no original "skin", S0; The final results shall be based on the same type of samples, the sample type shall be recorded in the report. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.