HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (12 Jan 2025)

GB/T 37619-2019 PDF English


Search result: GB/T 37619-2019_English: PDF (GB/T37619-2019)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 37619-2019English150 Add to Cart 0-9 seconds. Auto-delivery. Corrosion of metals and alloys -- Potentiostatic test and evaluation method for determination of susceptibility to grooving corrosion of high frequency electric resistance welded steel pipes Valid
BUY with any currencies (Euro, JPY, GBP, KRW etc.): GB/T 37619-2019     Related standards: GB/T 37619-2019

PDF Preview: GB/T 37619-2019


GB/T 37619-2019: PDF in English (GBT 37619-2019)

GB/T 37619-2019 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 77.060 H 25 Corrosion of Metals and Alloys - Potentiostatic Test and Evaluation Method for Determination of Susceptibility to Grooving Corrosion of High Frequency Electric Resistance Welded Steel Pipes ISSUED ON: JUNE 04, 2019 IMPLEMENTED ON: MAY 01, 2020 Issued by: State Administration for Market Regulation; Standardization Administration of PRC. Table of Contents Foreword ... 3 Introduction ... 4 1 Scope ... 5 2 Normative References ... 5 3 Terms and Definitions ... 5 4 Principle ... 6 5 Devices and Materials ... 6 6 Preparation of Specimen and Solution ... 7 7 Procedures ... 8 8 Evaluation of Test Results ... 10 9 Test Report ... 10 Appendix A (Informative) Potential of Optional Reference Electrode at 25°C corresponding to Standard Hydrogen Electrode (SHE) ... 11 Corrosion of Metals and Alloys - Potentiostatic Test and Evaluation Method for Determination of Susceptibility to Grooving Corrosion of High Frequency Electric Resistance Welded Steel Pipes 1 Scope This Standard specifies a method for evaluating the grooving corrosion of high- frequency electric resistance welded steel pipes by using the constant potential anodic polarization method in a 3.5% NaCl solution. This Standard is applicable to the test of grooving corrosion for carbon steel high- frequency electric resistance welded pipes. 2 Normative References The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document. GB/T 16545 Corrosion of Metals and Alloys - Removal of Corrosion Products from Corrosion Test Specimens GB/T 18590-2001 Corrosion of Metals and Alloys - Evaluation of Pitting Corrosion JB/T 10579-2006 Standard Practice for Applying Statistics of Corrosion Data 3 Terms and Definitions For the purposes of this document, the following terms and definitions apply. 3.1 Grooving corrosion The corrosion state that occurs at the weld junction and forms a deep-valley or horseshoe-shaped narrow groove. 3.2 Grooving corrosion sensitivity coefficient The ratio of the maximum corrosion depth (the sum of the average corrosion depth of the specimen and the maximum grooving corrosion depth) and the average corrosion depth of the specimen at the junction. 4 Principle Since the difference in composition, structure and residual stress BETWEEN the high- frequency electric resistance steel pipes weld-seam AND the base metal, the welded steel pipes may form the corrosion groove at the weld junction during the serving process. Such difference can be highlighted by applying appropriate anode potential to the welded steel pipe weld-seam for polarization, and further rapidly characterize the resistance of grooving corrosion of the high-frequency electric resistance welded steel pipe weld-seam. 5 Devices and Materials 5.1 Potentiostat The potentiostat shall meet the following requirements: --- Voltage range: -2V ~ +2V; --- Current range: -1A ~ +1A; --- Voltage resolution shall be no less than 1mV; --- Current resolution shall be no less than 0.01mA. 5.2 Tested electrolytic cell The tested electrolytic cell shall contain a working electrode (specimen), one is used a s the reference electrode for measuring the electrode potential; and one or two auxiliary electrodes. The tested electrolytic cell shall have a gas inlet and a gas outlet. The auxiliary electrode shall be placed reasonably so that the current on the sample can evenly distributed. In order to minimize the solution resistance between the reference electrode and the working electrode; the front end of the capillary shall be placed approximately 2 times the capillary diameter away from the working electrode, but no close than the position of 2 times the capillary diameter. The tested electrolytic cell shall be made of a material that is inert under the test temperature environment. The solution volume on the sample surface is greater than 500mL/cm2. The composition and installation of the tested electrolytic cell can refer to Figure 1. Key: Figure 3 – Metallographic Photo of Corroded Groove Section of a High- Frequency Electric Resistance Welded Steel Pipe Products 8 Evaluation of Test Results At least measure 3 parallel specimens; use the measured maximum Value-a to evaluate the groove corrosion. The parallel samples and data statistical analysis shall conform to the provisions of JB/T 10579-2006. The groove corrosion sensitivity increases as the increase of groove corrosion sensitivity coefficient, α. The larger the Value-α means that the groove corrosion is more likely to occur. 9 Test Report The test report shall at least contain the following contents: --- This Standard number; --- Test laboratory; --- Relevant information of sample; --- Test environmental conditions; --- Instrument types for test; --- Value-α. 1 – original surface; 2 – measurement baseline; 3 – heat affected zone; 4 – junction; 5 – groove. ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.