NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 97.120
K 32
Mechanical Magnetic Proximity Switches
for Household and Similar Use
ISSUED ON. JUNE 7, 2018
IMPLEMENTED ON. JANUARY 1, 2019
Issued by. State Administration for Market Regulation of the People’s
Republic of China;
Standardization Administration Committee of the People’s
Republic of China.
Table of Contents
Foreword ... 3 
1 Scope ... 4 
2 Normative References ... 4 
3 Terms and Definitions ... 5 
4 Model Naming and Classification ... 5 
5 Technical Requirements ... 6 
6 Test Methods ... 8 
7 Inspection Rules ... 11 
8 Marking, Packaging, Transportation and Storage ... 13 
Appendix A (normative appendix) ... 15 
Mechanical Magnetic Proximity Switches
for Household and Similar Use
1 Scope
This Standard specifies the terms, definitions, model naming, classification, technical
requirements, test methods, inspection rules, marking, packaging, transportation and
storage of mechanical magnetic proximity switches (hereinafter referred to as proximity
switches) for household and similar use.
This Standard is applicable to proximity switches that bear magnetic sensors and
implement switching-on/off under the driving force of magnetic field (rated voltage AC
< 380 V, or rated voltage DC < 300 V, rated current < 16 A).
2 Normative References
The following documents are indispensable to the application of this Standard. In terms
of references with a specified date, only versions with a specified date are applicable
to this Standard. The latest version (including all the modifications) of references
without a specified date is also applicable to this Standard.
GB/T 191 Packaging - Pictorial Marking for Handling of Goods
GB/T 2423.1 Environmental Testing for Electric and Electronic Products - Part 2.
Test Methods - Test A. Cold
GB/T 2423.2 Environmental Testing for Electric and Electronic Products - Part 2.
Test Methods - Test B. Dry Heat
GB/T 2423.5 Environmental Testing for Electric and Electronic Products - Part 2.
Test Methods - Test Ea and Guidance. Shock
GB/T 2423.10 Environmental Testing for Electric and Electronic Products - Part 2.
Test Methods - Test Fc and Guidance. Vibration (Sinusoidal)
GB/T 2828.1-2012 Sampling Procedures for Inspection by Attribute - Part 1.
Sampling Schemes Indexed by Acceptance Quality Limit (AQL) for Lot-by-lot
Inspection
GB 4706.1 Safety of Household and Similar Electrical Appliances - Part 1. General
Requirements
GB/T 14048.10 Low-voltage Switchgear and Control-gear - Part 5-2. Control
Circuit Devices and Switching Element - Proximity Switches
5.4.3 Contact resistance
At room temperature, resistance value shall be < 50 MΩ (contact resistance does not
include lead resistance).
5.5 Environmental Adaptability
5.5.1 Heat and humidity resistance
After heat and humidity resistance test (relative humidity. 95%), product shall comply
with requirements in 5.3 and 5.4.1.
5.5.2 Low temperature resistance
After low temperature resistance test (at -25 °C), product shall comply with
requirements in 5.3 and 5.4.1.
5.5.3 High temperature resistance
After high temperature resistance test (under highest ambient temperature), product
shall comply with requirements in 5.3 and 5.4.1.
5.5.4 High and low temperature impact
After high and low temperature impact test (at -25 °C and 120 °C), product shall comply
with requirements in 5.3 and 5.4.1.
5.6 Heat, Flame and Tracking Resistance
Proximity switch shall be able to endure.
a) Heat resistance. non-metallic materials that support electrical parts in proximity
switch shall be able to endure ball pressure test (at 125 °C). Other parts (for
example, external shell) shall be able to endure ball pressure test (at 40 °C
higher than the highest ambient temperature);
b) Flame resistance. proximity switch shall be able to endure glow-wire test (at
650 °C, 2 s);
c) Tracking resistance. no breakage or combustion shall be triggered in four
grades of test. 175 V, 250 V, 400 V, 600 V (determined in accordance with
illustration or instruction for use).
5.7 Free Fall
After free fall test, product shall comply with requirements in 5.3 and 5.4.3.
5.8 Vibration Resistance
resistance;
d) Division value of dielectric voltage withstand testing meter ≥ Level 1.5;
e) Division value of length measurement ≥ 0.02 mm;
f) Division value of timer. 0.1 s.
6.2 External Structure and Dimension
Examine in accordance with drawings; the method of visual inspection shall be
adopted in external structure; shape and dimension shall be measured directly with
corresponding measurer.
6.3 Action Distance
In accordance with the requirements of technical specification negotiated by the
demand side and the supply side, link up this product with DC resistance meter at room
temperature. Proximity switch and magnet trigger relative displacement; record action
distance when the resistance meter displays a numerical value.
6.4 Electrical Performance
6.4.1 Insulation resistance
Link up outgoing line with test electrode, link up the external shell with another side of
test electrode; impose 500 V DC voltage for 30 s, then, record the insulation resistance.
6.4.2 Electrical strength
Link up outgoing line with test electrode, link up the external shell with another side of
test electrode; conduct the test in accordance with stipulations in GB/T 14536.1.
6.4.3 Contact resistance
Link up outgoing line with resistance meter, maintain the switching-on state, record
the resistance value.
6.5 Environmental Adaptability
6.5.1 Heat and humidity resistance
In terms of general purposes, maintain 100 h in a thermostat (temperature. 55 °C ~
65 °C, relative humidity. 90% ~ 100 %); place 2 h at room temperature. Conduct the
test; assess if it satisfies the requirement in 5.4.1. As to heat and humidity resistance
test of proximity switch used under the occasion of steam pressure, test shall be
conducted in accordance with Appendix A.
6.5.2 Low temperature resistance
c) Rated voltage and current;
d) Batch number.
8.1.2 There shall be a distinct mark on the package, which includes.
a) Name or trademark, address of manufacturer;
b) Production date or batch number;
c) Model and product name;
d) Rated voltage and current;
e) Executive standard number, etc.;
f) Weight, volume and quantity;
g) Packaging storage and transportation mark stipulated in GB/T 191.
8.2 Packaging
Product packaging shall comply with requirements in GB/T 22685.
8.3 Transportation
Proximity switch with intact packaging can be transported with regular means of
transportation. sea, land and air; direct attack of rain or snow shall be avoided.
Proximity switch shall also be protected from humidity.
8.4 Storage
Packaged proximity switch shall be stored in a warehouse (ambient temperature. -
10 °C ~ + 60 °C, relative humidity ≤ 95%); there shall be no acid or alkaline gas, or
other harmful gas.
......
 