HOME   Cart(12)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 23978-2020 PDF English

US$105.00 · In stock · Download in 9 seconds
GB/T 23978-2020: Determination of chloride in water-soluble dyes
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

GB/T 23978: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
GB/T 23978-2020English105 Add to Cart 0-9 seconds. Auto-delivery Determination of chloride in water-soluble dyes Valid
GB/T 23978-2009English319 Add to Cart 3 days Liquid dyes -- Determination of chloride ion -- Ion chromatography Obsolete

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: GB/T 23978-2020
      

Similar standards

GB/T 24167   GB/T 24166   GB/T 24164   GB/T 23973   

GB/T 23978-2020: Determination of chloride in water-soluble dyes

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT23978-2020
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 71.100.01; 87.060.10 G 55 Replacing GB/T 23978-2009 Determination of chloride in water-soluble dyes ISSUED ON: NOVEMBER 19, 2020 IMPLEMENTED ON: OCTOBER 01, 2021 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China.

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Determination methods ... 4 4 Test report ... 9 Appendix A (Informative) Ion chromatogram for the determination of chloride in water-soluble dyes ... 10 Determination of chloride in water-soluble dyes

1 Scope

This Standard specifies the determination method of chloride in water-soluble dyes. This Standard applies to various water-soluble dyes.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document. GB/T 601, Chemical reagent - Preparations of reference titration solutions GB/T 603, Chemical reagent - Preparations of reagent solutions for use in test methods GB/T 6682-2008, Water for analytical laboratory use - Specification and test methods (ISO 3696:1987, MOD) GB/T 8170-2008, Rules of rounding off for numerical values & expression and judgement of limiting values

3 Determination methods

3.1 Ion chromatography 3.1.1 Determination principle For the pre-treated water-soluble dye sample solution, use the ion chromatography, with retention time for qualitative determination and peak area external standard method for quantitative determination, to determine its chloride content (as NaCl). 3.1.2 General provisions Unless otherwise specified, use only reagents that are identified as analytical reagents, and grade-3 water that is specified in GB/T 6682-2008. The Burn the sodium chloride at 500 °C to a constant amount; then, weigh about 1.000 g (accurate to 0.000 1 g) in a 1 000 mL volumetric flask; add water to dissolve and dilute to a constant volume; prepare a sodium chloride solution whose concentration is 1 000 μg/mL. Then, prepare linear standard solutions of seven concentrations of 0.01 μg/mL, 0.05 μg/mL, 0.1 μg/mL, 0.5 μg/mL, 1.0 μg/mL, 5.0 μg/mL, and 10.0 μg/mL for use. 3.1.8 Determination After the instrument is running stably, use a syringe to respectively draw the standard solution and sample solution to fill the quantitative loop for injection. After the chloride ion peak has flowed out (see Figure A.1 in Appendix A), use the chromatographic workstation to process the results. Determine the peak area of sodium chloride in the standard solution; draw a standard curve; then, calculate the chloride content in the sample according to the standard curve. 3.1.9 Result calculation The standard curve equation of sodium chloride is calculated according to Formula (1): The content of chloride (calculated as NaCl) in the sample is calculated, as mass fraction w1 (%), according to Formula (2): Where: A -- peak area value of sodium chloride; k -- constant of the sodium chloride standard curve equation, which is given by the chromatographic workstation; ρ -- concentration of sodium chloride in the solution, in micrograms per milliliter (μg/mL); b -- constant of the sodium chloride standard curve equation, which is given by the chromatographic workstation; V1 -- value of the final constant volume of the sample solution, in milliliters (mL); n -- value of the dilution ratio of the sample; m1 -- value of the mass of the sample, in grams (g); 3.2.3.2 Nitric acid. 3.2.3.3 Nitric acid solution: the volume ratio of nitric acid to water = 1:1. 3.2.3.4 Nitrobenzene. 3.2.3.5 Silver nitrate standard titration solution: c(AgNO3) = 0.1 mol/L. 3.2.3.6 Ferric ammonium sulfate test solution: Weigh 14 g of ferric ammonium sulfate; dissolve it in 100 mL of water; filter; add 10 mL of nitric acid; store in a brown bottle; place it in a refrigerator. The validity period is 6 months. 3.2.3.7 Ammonium thiocyanate standard titration solution: c(NH4SCN) = 0.1 mol/L. 3.2.4 Preparation of sample solution Weigh about 2 g (accurate to 0.000 1 g) of the sample; dissolve it in 150 mL of water; add 15 g of activated carbon; gently boil for 2 min ~ 3 min. Cool to room temperature; add 1 mL of nitric acid solution; place for 30 min (shake it occasionally). Use a Buchner funnel for suction filtration. If the filtrate is colored, add another 5 g of activated carbon; place for 1 h while shaking it from time to time; then, use a Buchner funnel for suction filtration (if there is still color, replace the activated carbon and repeat the operation until the filtrate is colorless). Use 10 mL of water to wash the activated carbon 3 times; combine and transfer the filtrate to a 250 mL volumetric flask; use water to fix volume; shake well; set aside. 3.2.5 Determination steps Pipette 50.00 mL of the sample solution (3.2.4); place it in a 250 mL conical flask; add 2 mL of nitric acid solution (3.2.3.3), 10.00 mL of silver nitrate standard titration solution (3.2.3.5) and 5 mL of nitrobenzene; vigorously shake until the silver chloride precipitates and coagulates; add 1 mL of ferric ammonium sulfate test solution; use the ammonium thiocyanate standard titration solution to titrate the excess silver nitrate; the solution changes from light yellow to light red as the end point; keep it for 1 min. Do a blank test at the same time. Note: If the chloride content is high, and the chloride ion in the sample cannot be completely precipitated with 10.00 mL of silver nitrate standard titration solution, dilute the sample solution. 3.2.6 Result calculation The content of chloride (calculated as NaCl) in the sample is calculated, as mass fraction w2 (%), according to Formula (3): ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of GB/T 23978-2020 be delivered?

Answer: The full copy PDF of English version of GB/T 23978-2020 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 23978-2020_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 23978-2020_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- GB/T 23978-2020 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GB/T 23978-2020?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 23978-2020 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GB/T 23978-2020?

A step-by-step guide to download PDF of GB/T 23978-2020_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 23978-2020".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9